Improvement in the surface properties of stainless steel via zein/hydroxyapatite composite coatings for biomedical applications

被引:32
|
作者
Ahmed, Yusra [1 ]
Rehman, Muhammad Atiq Ur [1 ]
机构
[1] Inst Space Technol Islamabad, Dept Mat Sci & Engn, 1 Islamabad Highway, Islamabad 44000, Pakistan
关键词
Zein; Hydroxyapatite; Electrophoretic deposition; Taguchi design of experiment; ELECTROPHORETIC DEPOSITION; CHITOSAN/BIOACTIVE GLASS; ZEIN; DESIGN; HA;
D O I
10.1016/j.surfin.2020.100589
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Although stainless steel is renowned for its wide use as a biomaterial, but relatively higher corrosion rate in physiological environment restricts its clinical applications. To overcome the corrosion resistance of stainless steel bio-implants in physiological environment and to improve the osseointegration behavior we developed zein/hydroxyapatite (HA) composite coatings deposited on stainless steel substrate by Electrophoretic Deposition (EPD). The EPD parameters were optimized using the Taguchi Design of Experiment (DoE) approach. The EPD parameters such as the concentration of bio-ceramic particles in the polymer solution, applied voltage, and deposition time were optimized on stainless steel substrates by applying mixed design orthogonal Taguchi array. The coatings were characterized by using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and wettability studies. SEM images and EDX results indicated that zein/HA coating was successfully deposited on stainless steel substrates. The wettability and roughness studies elucidated the mild hydrophilic nature of the zein/HA coatings, which confirmed the suitability of the developed coatings for biomedical applications. Zein/HA coatings improved the corrosion resistance of bare 316L stainless steel. Moreover, zein/HA coatings showed suitable adhesion with the 316L SS substrate for biomedical applications. Zein/HA coatings developed dense HA crystal upon immersion in simulated body fluid, which confirmed the bone binding ability of the coatings. Thus, the zein/HA coatings presented strong potential to be considered for orthopedic applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fabrication and Characterization of Zein/Hydroxyapatite Composite Coatings for Biomedical Applications
    Ahmed, Yusra
    Yasir, Muhammad
    Ur Rehman, Muhammad Atiq
    SURFACES, 2020, 3 (02): : 237 - 250
  • [2] Impact of Surface Treatment on the Functional Properties Stainless Steel for Biomedical Applications
    Basiaga, Marcin
    Walke, Witold
    Antonowicz, Magdalena
    Kajzer, Wojciech
    Szewczenko, Janusz
    Domanowska, Alina
    Michalewicz, Anna
    Szindler, Marek
    Staszuk, Marcin
    Czajkowski, Milosz
    MATERIALS, 2020, 13 (21) : 1 - 17
  • [3] Electrophoretic deposition of chitosan/gelatin/hydroxyapatite nanocomposite coatings on 316 L stainless steel for biomedical applications
    Mohammadsadegh, Ali
    Allahkaram, Saeed Reza
    Gharagozlou, Mehrnaz
    BIOMEDICAL MATERIALS, 2025, 20 (01)
  • [4] Paclitaxel/hydroxyapatite composite coatings on titanium alloy for biomedical applications
    Lai, Yu-Liang
    Lai, Shuei-Bin
    Yen, Shiow-Kang
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 79 : 622 - 628
  • [5] Effect of TiN/TiO2 multilayer coatings on the properties of stainless steel for biomedical applications
    Hikov, T.
    Nikolova, M.
    Petrov, P.
    21ST INTERNATIONAL SUMMER SCHOOL ON VACUUM, ELECTRON AND ION TECHNOLOGIES, 2020, 1492
  • [6] Microporous Organic-Inorganic Nanocomposite Coatings On Stainless Steel Via Electrophoretic Deposition For Biomedical Applications
    Abdullah, H. Z.
    Boccaccini, A. R.
    ELECTROPHORETIC DEPOSITION VI, 2018, 82 (01): : 25 - 31
  • [7] Mg-Doped Hydroxyapatite/Chitosan Composite Coated 316L Stainless Steel Implants for Biomedical Applications
    Sutha, S.
    Dhineshbabu, N. R.
    Prabhu, M.
    Rajendran, V.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2015, 15 (06) : 4178 - 4187
  • [8] Modification of 2205 duplex stainless steel properties through solution heat treatment and surface enhancement with sol gel coatings for biomedical applications
    Abd Al-reda, Alaa Khalid
    Dawood, Nawal Mohammed
    Kareem, Shaima'a J.
    JOURNAL OF CERAMIC PROCESSING RESEARCH, 2024, 25 (03):
  • [9] Improvement of adhesion and barrier properties of biomedical stainless steel by deposition of YSZ coatings using RF magnetron sputtering
    Sanchez-Hernandez, Z. E.
    Dominguez-Crespo, M. A.
    Torres-Huerta, A. M.
    Onofre-Bustamante, E.
    Andraca Adame, J.
    Dorantes-Rosales, H.
    MATERIALS CHARACTERIZATION, 2014, 91 : 50 - 57
  • [10] Soapstone reinforced hydroxyapatite coatings for biomedical applications
    Mota, Laureana Moreira
    Nunes Nicomedes, Daniel Nilson
    Moreira Barboza, Ana Paula
    Lima de Moraes Ramos, Sergio Luis
    Vasconcellos, Rebecca
    Medrado, Nathanael Vieira
    de Alvarenga, Erika Costa
    Machado, Giovanna
    Juste, Karyne R. C.
    de Vasconcelos, Claudia Karina
    Righi, Ariete
    Manhabosco, Sara Matte
    Resende, Rodrigo Ribeiro
    Campos Batista, Ronaldo Junio
    Soares, Jaqueline dos Santos
    Manhabosco, Taise Matte
    SURFACE & COATINGS TECHNOLOGY, 2020, 397