3D high-density localization microscopy using hybrid astigmatic/biplane imaging and sparse image reconstruction

被引:33
|
作者
Min, Junhong [1 ]
Holden, Seamus J. [2 ]
Carlini, Lina [2 ]
Unser, Michael [3 ]
Manley, Suliana [2 ]
Ye, Jong Chul [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Taejon 305701, South Korea
[2] Ecole Polytech Fed Lausanne, Inst Phys Biol Syst, CH-1015 Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne, Biomed Imaging Grp, CH-1015 Lausanne, Switzerland
来源
BIOMEDICAL OPTICS EXPRESS | 2014年 / 5卷 / 11期
基金
欧洲研究理事会;
关键词
D O I
10.1364/BOE.5.003935
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Localization microscopy achieves nanoscale spatial resolution by iterative localization of sparsely activated molecules, which generally leads to a long acquisition time. By implementing advanced algorithms to treat overlapping point spread functions (PSFs), imaging of densely activated molecules can improve the limited temporal resolution, as has been well demonstrated in two-dimensional imaging. However, three-dimensional (3D) localization of high-density data remains challenging since PSFs are far more similar along the axial dimension than the lateral dimensions. Here, we present a new, high-density 3D imaging system and algorithm. The hybrid system is implemented by combining astigmatic and biplane imaging. The proposed 3D reconstruction algorithm is extended from our state-of-the art 2D high-density localization algorithm. Using mutual coherence analysis of model PSFs, we validated that the hybrid system is more suitable than astigmatic or biplane imaging alone for 3D localization of high-density data. The efficacy of the proposed method was confirmed via simulation and real data of microtubules. Furthermore, we also successfully demonstrated fluorescent-protein-based live cell 3D localization microscopy with a temporal resolution of just 3 seconds, capturing fast dynamics of the endoplasmic recticulum. (C) 2014 Optical Society of America
引用
收藏
页码:3935 / 3948
页数:14
相关论文
共 50 条
  • [1] A high-density 3D localization algorithm for stochastic optical reconstruction microscopy
    Babcock, Hazen
    Sigal, Yaron M.
    Zhuang, Xiaowei
    Optical Nanoscopy, 2012, 1 (01) : 1 - 10
  • [2] High density 3D localization microscopy using sparse support recovery
    Ovesny, Martin
    Krizek, Pavel
    Svindrych, Zdenek
    Hagen, Guy M.
    OPTICS EXPRESS, 2014, 22 (25): : 31263 - 31276
  • [3] SUPER-RESOLUTION IMAGE RECONSTRUCTION FOR HIGH-DENSITY 3D SINGLE-MOLECULE MICROSCOPY
    Huang, Jiaqing
    Sun, Mingzhai
    Chi, Yuejie
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 241 - 244
  • [4] Sparse Statistical Deconvolution for High-Density Localization Microscopy
    Mukamel, Eran A.
    Babcock, Hazen
    Zhuang, Xiaowei
    BIOPHYSICAL JOURNAL, 2012, 102 (03) : 723A - 724A
  • [5] 3D localization of high particle density images using sparse recovery
    Zhang, Saiwen
    Chen, Danni
    Niu, Hanben
    APPLIED OPTICS, 2015, 54 (26) : 7859 - 7864
  • [6] ACCELERATED 3D LOCALIZATION MICROSCOPY USING BLIND SPARSE INPAINTING
    Gaire, Sunil Kumar
    Zhang, Chaoyi
    Li, Hongyu
    Huang, Peizhou
    Liu, Ruiying
    Wang, Haifeng
    Bang, Dong
    Ying, Leslie
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 526 - 529
  • [7] 2D and 3D image localization, compression and reconstruction using new hybrid moments
    Tahiri, Mohamed Amine
    Karmouni, Hicham
    Sayyouri, Mhamed
    Qjidaa, Hassan
    MULTIDIMENSIONAL SYSTEMS AND SIGNAL PROCESSING, 2022, 33 (03) : 769 - 806
  • [8] 3D reconstruction of coronary artery using biplane angiography
    Law, AKW
    Zhu, H
    Chan, FHY
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 533 - 536
  • [9] Correction to: 2D and 3D image localization, compression and reconstruction using new hybrid moments
    Mohamed Amine Tahiri
    Hicham Karmouni
    Mhamed Sayyouri
    Hassan Qjidaa
    Multidimensional Systems and Signal Processing, 2022, 33 : 1069 - 1069
  • [10] High-density WGM probes generated by a ChG ring resonator for high-density 3D imaging and applications
    Youplao, Phichai
    Pornsuwancharoen, Nithiroth
    Suwanarat, Suksan
    Chaiwong, Khomyuth
    Jalil, Muhammad Arif
    Amiri, Iraj. S.
    Ali, Jalil
    Singh, Ghanshyam
    Yupapin, Preecha
    Grattan, Kenneth T. V.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2018, 60 (11) : 2689 - 2693