Development of solid-phase microextraction fibers based on multi-walled carbon nanotubes for pre-concentration and analysis of alkanes in human breath

被引:11
|
作者
Tang, Zhentao [1 ]
Liu, Yong [1 ]
Duan, Yixiang [2 ]
机构
[1] Sichuan Univ, Res Ctr Analyt Instrumentat, Analyt & Testing Ctr, Chengdu 610064, Peoples R China
[2] Sichuan Univ, Res Ctr Analyt Instrumentat, Key Lab Bioresource & Ecoenvironm, Minist Educ,Coll Life Sci, Chengdu 610064, Peoples R China
基金
美国国家科学基金会;
关键词
Multi-walled carbon nanotubes; SPME; Sol-gel technology; Human breath; Alkanes; Microwave induced plasma; VOLATILE ORGANIC-COMPOUNDS; GAS-CHROMATOGRAPHY; EXHALED BREATH; WATER SAMPLES; LUNG-CANCER; GEL; PLASMA; COATINGS; PHENOLS;
D O I
10.1016/j.chroma.2015.11.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a laboratory preparation method based on sol-gel technology was proposed to develop a new kind of SPME (solid phase microextraction) fibers. Multi-walled carbon nanotubes (MWCNT) were selected as sol-gel active organic component. Stainless steel wires were used as the substrate of the fibers. Instead of traditional modification methods, microwave induced plasma was used to modify the stainless steel wire surface, resulting in a significant improvement in chemical adhesion of the fiber substrate and coating. The MWCNT coating exhibited several good properties. Acceptable fiber-to-fiber reproducibility (RSD <= 13%) and repeatability (RSD < 7%) were obtained. End-tidal breath of 10 normal humans were collected by Bio-VOC (R) sampler and assayed by the optimized SPME-GC-MS method. The calibration curves were all linear (R-2 >= 0.994) in the range from 0.03 to 403.3 ppbv for five alkanes. Detection limits (down to 0.001 ppbv) were about one order of magnitude better than those of commercial PDMS fibers. The recovery of the spiked alkanes in real breath sample at 1 ppbv ranged from 89.71 to 101.08% and the relative standard deviations were less than 8%. These results demonstrated the feasibility and practicality of the proposed preparation procedure. Applications of the in-house fabricated fibers for human breath analysis were successfully verified. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 50 条
  • [1] Isolation and pre-concentration of basic proteins in aqueous mixture via solid-phase extraction with multi-walled carbon nanotubes assembled on a silica surface
    Du, Zhuo
    Yu, Yong-Liang
    Yan, Xiao-Rui
    Wang, Jian-Hua
    ANALYST, 2008, 133 (10) : 1373 - 1379
  • [2] An electrochemically enhanced solid-phase microextraction approach based on a multi-walled carbon nanotubes/Nafion composite coating
    Zeng, Jingbin
    Chen, Jinmei
    Song, Xinhong
    Wang, Yiru
    Ha, Jaeho
    Chen, Xi
    Wang, Xiaoru
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (11) : 1735 - 1741
  • [3] Preparation of metal wire supported solid-phase microextraction fiber coated with multi-walled carbon nanotubes
    Feng, Juanjuan
    Sun, Min
    Xu, Lili
    Li, Jubai
    Liu, Xia
    Jiang, Shengxiang
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (18) : 2482 - 2488
  • [4] Multi-walled carbon nanotubes: innovative sorbents for pre-concentration of polychlorinated biphenyls in aqueous environments
    Ndunda, Elizabeth N.
    Mizaikoff, Boris
    ANALYTICAL METHODS, 2015, 7 (19) : 8034 - 8040
  • [5] Sensitive magnetic solid-phase microextraction based on oxide multi-walled carbon-nanotubes for the determination of methylamphetamine and ketamine in human urine and blood
    Zhang, Suling
    Cui, Yanhua
    Sun, Jiancong
    Xi, Yongqing
    Zhang, Chunxiao
    Tang, Junhong
    ANALYTICAL METHODS, 2015, 7 (10) : 4209 - 4215
  • [6] Solid-phase microextraction for the analysis of human breath
    Grote, C
    Pawliszyn, J
    ANALYTICAL CHEMISTRY, 1997, 69 (04) : 587 - 596
  • [7] Methods for coating solid-phase microextraction fibers with carbon nanotubes
    Ghaemi, Ferial
    Amiri, Amirhassan
    Yunus, Robiah
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 133 - 143
  • [8] Facile modification of multi-walled carbon nanotubes-polymeric ionic liquids-coated solid-phase microextraction fibers by on-fiber anion exchange
    Feng, Juanjuan
    Sun, Min
    Bu, Yanan
    Luo, Chuannan
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1393 : 8 - 17
  • [9] Solid phase microextraction for analysis of alkanes and aromatic hydrocarbons in human breath
    Yu, H
    Xu, L
    Wang, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2): : 69 - 74
  • [10] Magnetic nanoparticles modified with polydimethylsiloxane and multi-walled carbon nanotubes for solid-phase extraction of fluoroquinolones
    Xu, Shen
    Jiang, Cheng
    Lin, Yuexin
    Jia, Li
    MICROCHIMICA ACTA, 2012, 179 (3-4) : 257 - 264