Noninvasive high-resolution detection of the arterial and venous input function through a PET wrist scanner

被引:0
|
作者
Kriplani, A. [1 ]
Stoll, S. P. [1 ]
Southekal, S. [1 ]
Schlyer, D. J. [1 ]
Park, S. J. [1 ]
Villanueva, A. [1 ]
Pratte, J. F. [1 ]
Junnarkar, S. [1 ]
Vaska, P. [1 ]
Woody, C. L. [1 ]
机构
[1] SUNY Stony Brook, Stony Brook, NY 11794 USA
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to assess the kinetics of radiotracer accumulation in tissue, the amount of radioactivity in the blood must be quantitatively measured as an input function to the kinetic model. Due to safety and comfort issues with invasive determination of the input function, a non-invasive method for arterial measurement of blood radioactivity is investigated using a wrist scanner. A prototype consisting of two detector pairs of LSO and APD detector arrays is used to obtain planar images of an anatomically correct wrist phantom. The spatial resolution and sensitivity of the prototype is determined. The results showed the detector was able to discriminate the arterial and venous flows from each other when using planar coincidence images.
引用
收藏
页码:2240 / 2244
页数:5
相关论文
共 50 条
  • [1] Spatial resolution of a noninvasive measurement of the arterial and venous input function using a wrist monitor
    Villanueva, A
    Stoll, SP
    Schlyer, DJ
    Shokouhi, S
    Vaska, P
    Woody, CL
    Kriplani, A
    Volkow, N
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2232 - 2236
  • [2] Non-invasive and selective measurement of the arterial input function using a PET Wrist Scanner
    Kriplani, A.
    Schlyer, D. J.
    Vaska, P.
    Stoll, S. P.
    Southekal, S.
    Park, S. J.
    Woody, C. L.
    Junnarkar, S.
    Pratte, J. F.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3266 - 3270
  • [3] ORTHO-POSITRONIUM DETECTION WITH A HIGH-RESOLUTION PET SCANNER
    Abouzahr, Firas
    Cesar, John P.
    Gajda, Michael
    Kuo, Alex S.
    Lang, Karol
    Liu, Jingchun
    Ojha, Aryan
    Proga, Marek
    Crespo, Paulo
    Morozov, Andrey
    Acta Physica Polonica B, Proceedings Supplement, 2024, 17 (07)
  • [4] Measurement of the arterial input function at high temporal resolution in dynamic PET.
    Bellemann, ME
    Haberkorn, U
    Brix, G
    Gerlach, L
    Lorenz, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1189 - 1189
  • [5] A new high-resolution PET scanner dedicated to brain research
    Watanabe, M
    Shimizu, K
    Omura, T
    Takahashi, M
    Kosugi, T
    Yoshikawa, E
    Sato, N
    Okada, H
    Yamashita, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 634 - 639
  • [6] ASSESSMENT OF SCATTER COMPONENTS IN A VERY HIGH-RESOLUTION PET SCANNER
    BENTOURKIA, M
    MSAKI, P
    CADORETTE, J
    HEON, M
    LECOMTE, R
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P136 - P136
  • [7] STUDY OF A HIGH-RESOLUTION 3D PET SCANNER
    ZHANG, SP
    BRUYNDONCKX, P
    GOLDBERG, MB
    TAVERNIER, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 607 - 612
  • [8] Human studies using a wrist scanner for non-invasive determination of the arterial input function
    Ravindranath, Bosky
    Junnarkar, Sachin
    Purschke, Martin
    Stoll, Sean
    Maramraju, Harsha
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [9] Efficient System Modeling of a High-resolution Zoom-in PET Scanner
    Zhou, Jian
    Qi, Jinyi
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3501 - 3505
  • [10] PERFORMANCE EVALUATION OF THE HIGH-RESOLUTION PET SCANNER ECAT EXACT HR
    WIENHARD, K
    DAHLBOM, M
    ERIKSSON, L
    MICHEL, C
    PIETRZYK, U
    HEISS, WD
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P101 - P101