The first results on the cesium atomic fountain in INFLPR

被引:0
|
作者
Mandache, C [1 ]
Acsente, T [1 ]
Ungureanu, M [1 ]
机构
[1] Natl Inst Laser Plasma & Radiat Phys, Nucl Fus & Plasma Phys Lab, R-76900 Bucharest, Magurele, Romania
关键词
atomic fountain; optical molasses; laser cooling; magneto-optical trap (MOT); time of flight (TOF); extended laser cavity;
D O I
10.1117/12.378739
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The atomic fountain is a new high-performance primary frequency standard where the stability is of the order of 10(-17) and the accuracy of the order of 10(-16). Our goal is to realize such a standard in our laboratory. In an atomic fountain we can distinguish three basic part: the cesium atom source, the microwave and the C-field region, and the detection area. In this paper we briefly recall an atomic fountain operation and present the first research results obtained in our laboratory concerning the atomic cesium fountain.
引用
收藏
页码:645 / 650
页数:6
相关论文
共 50 条
  • [1] First results with a cold cesium continuous fountain resonator
    Dudle, G
    Joyet, A
    Berthoud, P
    Mileti, G
    Thomann, P
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 510 - 514
  • [2] NPLI Cesium Atomic Fountain Frequency Standard: Preliminary Results
    Arora, Poonam
    Purnapatra, Subhajit Banerjee
    Acharya, Aishik
    Agarwal, Ashish
    Yadav, Suchi
    Pant, Kavindra
    Sen Gupta, Amitava
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (07) : 2037 - 2042
  • [3] Priliminary results from the USNO cesium fountain atomic clock
    Burt, E
    Swanson, T
    Ekstrom, C
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 10 - 11
  • [4] First results of PTB's atomic caesium fountain
    Physikalisch-Technische, Bundesanstalt, Braunschweig, Germany
    Proc Annu IEEE Int Freq Control Symp, (16-19):
  • [5] Progress on the construction of an atomic cesium fountain at NIM
    Li, TC
    Li, MS
    Huang, BY
    Qian, J
    Lin, PW
    PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2001, : 101 - 104
  • [6] Atomic clock with cesium fountain frequency standard
    Bauch, A
    PTB-MITTEILUNGEN, 1998, 108 (01): : 3 - 18
  • [7] Development of a cesium atomic fountain frequency standard
    Kwon, TY
    Lee, HS
    Yang, SH
    Park, SE
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 462 - 463
  • [8] Development of a cesium atomic fountain frequency standard
    Kwon, TY
    Lee, HS
    Yang, SH
    Park, SE
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 263 - 266
  • [9] Progress in Brazilian cesium atomic fountain-BrCsF
    Rodriguez, S. A.
    Bagnato, V. S.
    Bueno, C.
    Pechoneri, R. D.
    Mueller, S. T.
    Magalhaes, D. V.
    2016 IEEE International Frequency Control Symposium (IFCS), 2016, : 412 - 415
  • [10] Compact Optical System For Cesium Atomic Fountain Clock
    Chen, Jiang
    Ruan, Jun
    Shi, Junru
    Yu, Fengxiang
    Zhang, Hui
    Wang, Xinliang
    Zhang, Shougang
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684