High-throughput fluorescence polarization immunoassay by using a portable fluorescence polarization imaging analyzer

被引:22
|
作者
Wakao, Osamu [1 ]
Satou, Ken [2 ]
Nakamura, Ayano [1 ]
Galkina, Polina A. [3 ]
Nishiyama, Keine [1 ]
Sumiyoshi, Ken [2 ]
Kurosawa, Fumio [4 ]
Maeki, Masatoshi [5 ]
Ishida, Akihiko [5 ]
Tani, Hirofumi [5 ]
Proskurnin, Mikhail A. [3 ]
Shigemura, Koji [2 ]
Hibara, Akihide [4 ]
Tokeshi, Manabu [5 ]
机构
[1] Hokkaido Univ, Grad Sch Chem Sci & Engn, Kita Ku, Kita 13 Nishi 8, Sapporo, Hokkaido 0608628, Japan
[2] Tianma Japan Ltd, Saiwai Ku, Shin Kawasaki Mitsui Bldg,West Tower 28F 1-1-2, Kawasaki, Kanagawa 2120058, Japan
[3] Moscow MV Lomonosov State Univ, Chem Dept, GSP-2, Moscow 119991, Russia
[4] Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Aoba Ku, Katahira 2-1-1, Sendai, Miyagi 9808577, Japan
[5] Hokkaido Univ, Fac Engn, Div Appl Chem, Kita Ku, Kita 13 Nishi 8, Sapporo, Hokkaido 0608628, Japan
关键词
MYCOTOXINS; SYSTEM; ASSAY; FOOD;
D O I
10.1039/c9lc00256a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-throughput fluorescence polarization immunoassays (FPIAs) for mycotoxin were conducted using a portable FP analyzer with a microdevice. Simultaneous FPIA measurements for 8 different deoxynivalenol (DON) concentrations in 12 chambers (total of 96 samples) and high-throughput FPIA measurements for single DON concentrations in more than 500 chambers were conducted. The results indicated that simultaneous FPIAs for 96 independent samples and for 500 samples were possible by FP imaging. The FP analyzer has a size of 65 cm (W 35 cm x D 15 cm x H 15 cm) and costs less than $5000. The sample volume was 1 nL. Furthermore, it is expected that sample reaction and FP detection can be automatically conducted with the analyzer by changing the microdevice and the software. Its features such as low cost and portability will contribute to on-site measurement and point-of-care testing. Additionally, the high-throughput feature will contribute to the study of molecular interactions based on FP measurements.
引用
收藏
页码:2581 / 2588
页数:8
相关论文
共 50 条
  • [1] Fluorescence polarization standards for high-throughput screening and imaging
    Thompson, RB
    Gryczynski, I
    Malicka, J
    BIOTECHNIQUES, 2002, 32 (01) : 34 - +
  • [2] Rapid determination of domoic acid in seafood by fluorescence polarization immunoassay using a portable analyzer
    Yu Ogura
    Mao Fukuyama
    Motohiro Kasuya
    Koji Shigemura
    Sergei A. Eremin
    Manabu Tokeshi
    Akihide Hibara
    Analytical Sciences, 2023, 39 : 2001 - 2006
  • [3] Rapid determination of domoic acid in seafood by fluorescence polarization immunoassay using a portable analyzer
    Ogura, Yu
    Fukuyama, Mao
    Kasuya, Motohiro
    Shigemura, Koji
    Eremin, Sergei A.
    Tokeshi, Manabu
    Hibara, Akihide
    ANALYTICAL SCIENCES, 2023, 39 (12) : 2001 - 2006
  • [4] A Specific and High-Throughput Fluorescence Polarization Immunoassay for Surveillance Screening of Clinafloxacin in Milk
    Jiahong Chen
    Shuwei Lv
    Qiang Wang
    Zhenlin Xu
    Jinyi Yang
    Yudong Shen
    Hong Wang
    Yuanming Sun
    Hongtao Lei
    Food Analytical Methods, 2015, 8 : 1468 - 1476
  • [5] A Specific and High-Throughput Fluorescence Polarization Immunoassay for Surveillance Screening of Clinafloxacin in Milk
    Chen, Jiahong
    Lv, Shuwei
    Wang, Qiang
    Xu, Zhenlin
    Yang, Jinyi
    Shen, Yudong
    Wang, Hong
    Sun, Yuanming
    Lei, Hongtao
    FOOD ANALYTICAL METHODS, 2015, 8 (06) : 1468 - 1476
  • [6] A high-throughput STAT binding assay using fluorescence polarization
    Wu, PG
    Brasseur, M
    Schindler, U
    ANALYTICAL BIOCHEMISTRY, 1997, 249 (01) : 29 - 36
  • [7] Rapid detection of anti-H5 avian influenza virus antibody by fluorescence polarization immunoassay using a portable fluorescence polarization analyzer
    Nishiyama, Keine
    Takeda, Yohei
    Maeki, Masatoshi
    Ishida, Akihiko
    Tani, Hirofumi
    Shigemura, Koji
    Hibara, Akihide
    Yonezawa, Yutaka
    Imai, Kunitoshi
    Ogawa, Haruko
    Tokeshi, Manabu
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 316
  • [8] Development of a simple, rapid and high-throughput fluorescence polarization immunoassay for glycocholic acid in human urine
    He, Qiyi
    Cui, Xiping
    Shen, Ding
    Chen, Yingshan
    Jiang, Zhengyun
    Lv, Rui
    Eremin, Sergei A.
    Zhao, Suqing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 431 - 437
  • [9] A High-Throughput Fluorescence Polarization Assay for Inhibitors of Gyrase B
    Glaser, Bryan T.
    Malerich, Jeremiah P.
    Duellman, Sarah J.
    Fong, Julie
    Hutson, Christopher
    Fine, Richard M.
    Keblansky, Boris
    Tanga, Mary J.
    Madrid, Peter B.
    JOURNAL OF BIOMOLECULAR SCREENING, 2011, 16 (02) : 230 - 238
  • [10] FLUORESCENCE POLARIZATION IMMUNOASSAY
    JOLLEY, ME
    CLINICAL CHEMISTRY, 1981, 27 (06) : 972 - 973