Role of Clinician's Experience and Implant Design on Implant Stability. An Ex Vivo Study in Artificial Soft Bones

被引:28
|
作者
Romanos, Georgios E. [1 ,2 ]
Basha-Hijazi, Abdulaziz [2 ]
Gupta, Bhumija [2 ]
Ren, Yan-Fang [2 ]
Malmstrom, Hans [2 ]
机构
[1] Univ Rochester, Div Periodont, Eastman Inst Oral Hlth, Rochester, NY 14620 USA
[2] Univ Rochester, Div Gen Dent, Eastman Inst Oral Hlth, Rochester, NY 14620 USA
关键词
clinician experience; implant stability; bone quality; RESONANCE FREQUENCY-ANALYSIS; IN-VITRO; DENSITY; MAXILLA; HYBRID;
D O I
10.1111/j.1708-8208.2012.00470.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. Methods: A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (o 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. Results: All implants were mechanically stable. The mean ISQ values were: 49.57(+/- 18.49) for the P-implants and 67.07(+/- 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p < .0001), clinician (p < .0001), and their interaction (p < .0001). The Tukey's multiple comparison test showed significant differences in RFA for the clinician group I/II (p = .015) and highly significant (p < .0001) between I/III and II/III. The P-implants presented (for I, II, and III) mean ISQ values 31.25/49.18/68.17 and the T-implants showed higher ISQ values, 70.15/62.08/68.98, respectively. Clinicians I and II did not show extreme differences for T-implants (p = .016). In contrast, clinician III achieved high ISQ values using P- and T-implants following the exact surgical protocol based on the manufacturer guidelines. T-implants provided high stability for experienced clinicians compared with P-implants. Conclusion: T-implants achieved greater PS than the P-implants. All clinicians consistently achieved PS; however, experienced clinicians achieved higher ISQ values with T-implants in poor quality bone.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 16 条
  • [1] Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study
    Herrero-Climent, Mariano
    Lemos, Bernardo Ferreira
    Herrero-Climent, Federico
    Falcao, Carlos
    Oliveira, Helder
    Herrera, Manuela
    Javier Gil, Francisco
    Rios-Carrasco, Blanca
    Rios-Santos, Jose-Vicente
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 13
  • [2] INFLUENCE OF CLINICIAN'S SKILL ON PRIMARY IMPLANT STABILITY WITH CONVENTIONAL AND PIEZOELECTRIC PREPARATION TECHNIQUES: AN EX-VIVO STUDY
    Giudice, A.
    Bennardo, F.
    Antonelli, A.
    Barone, S.
    Wagner, F.
    Fortunato, L.
    Traxler, H.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 (02): : 739 - 745
  • [3] The Influence of Implant Shape on Primary Stability of Implants With a Thread Cutting and Forming Design: An Ex Vivo Study
    Dayan, Cagatay
    Geckili, Onur
    Bural, Canan
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (03) : 181 - 185
  • [4] Implant primary stability depending on protocol and insertion mode — an ex vivo study
    Henning Staedt
    Peer W. Kämmerer
    Elisabeth Goetze
    Daniel G. E. Thiem
    Bilal Al-Nawas
    Diana Heimes
    International Journal of Implant Dentistry, 6
  • [5] Implant primary stability depending on protocol and insertion mode - an ex vivo study
    Staedt, Henning
    Kaemmerer, Peer W.
    Goetze, Elisabeth
    Thiem, Daniel G. E.
    Al-Nawas, Bilal
    Heimes, Diana
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [6] Effect of Residual Bone Height and Implant Macro-Design on Primary Stability in Sinus Floor Elevation: An Ex Vivo Study
    Tokuc, Berkay
    Cakir, Merve
    Ulker, Gul Merve Yalcin
    Geckili, Onur
    Meral, Deniz Gokce
    Kan, Bahadir
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (06) : 578 - 583
  • [7] Primary stability of different implant macrodesigns in a sinus floor elevation simulated model: an ex vivo study
    Imai, Mikio
    Ogino, Yoichiro
    Tanaka, Hideaki
    Koyano, Kiyoshi
    Ayukawa, Yasunori
    Toyoshima, Takeshi
    BMC ORAL HEALTH, 2022, 22 (01)
  • [8] Primary stability of different implant macrodesigns in a sinus floor elevation simulated model: an ex vivo study
    Mikio Imai
    Yoichiro Ogino
    Hideaki Tanaka
    Kiyoshi Koyano
    Yasunori Ayukawa
    Takeshi Toyoshima
    BMC Oral Health, 22
  • [9] Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
    Bandela, Vinod
    Shetty, Neema
    Munagapati, Bharathi
    Basany, Ram B.
    Kanaparthi, Saraswathi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (10)
  • [10] Does the Modification of the Apical Geometry of a Dental Implant Affect Its Primary Stability? A Comparative Ex Vivo Study
    Staedt, Henning
    Heimes, Diana
    Lehmann, Karl M.
    Ottl, Peter
    Bjelopavlovic, Monika
    Wagner, Wilfried
    Al-Nawas, Bilal
    Kaemmerer, Peer W.
    MATERIALS, 2021, 14 (07)