Velocity field measurements of blood flows using a synchrotron x-ray imaging technique

被引:0
|
作者
Kim, GB [1 ]
Lee, SJ [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Mech Engn, Pohang, Kyungbuk, South Korea
来源
关键词
RBC; x-ray PIV; synchrotron x-ray; Fresnel diffraction; velocity field measurement;
D O I
10.1117/12.528588
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The x-ray PIV technique was employed to measure instantaneous velocity fields of blood flow in an opaque microchannel. Generally, it is difficult for conventional clinical instruments to visualize detailed transport of blood cells or to acquire quantitative hemodynamic information due to poor spatial resolution. On the other hand, although conventional PIV techniques have higher spatial resolution, they can be applicable only to transparent fluids inside a clear conduit. In addition, seeding particles indispensable for PIV measurements can affect the biochemical characteristics of blood. In order to resolve these problems, we established an x-ray PIV technique by using a permeable x-ray beam as a light source of PIV technique. For acquiring good x-ray images of red blood cells from which velocity vectors can be extracted, the sample-detector distance and the thickness of sample fluid were optimized. By applying 2-frame PIV algorithm to the acquired x-ray images of red blood cells, the quantitative velocity field information was obtained. The measured velocity data of blood flow show typical flow characteristics in a macrochannel.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 50 条
  • [1] Synchrotron X-ray PIV technique for measurement of blood flow velocity
    Kim, Guk Bae
    Je, Jung Ho
    Lee, Sang Joon
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1891 - +
  • [2] Medical X-ray PIV technique for visualizing quantitative velocity field distributions of blood flows
    Yim, Dae-Hyun
    Kim, Guk Bae
    Kim, Do-Il
    Lee, Hyoung-Koo
    Lee, Sang Joon
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 742 - +
  • [3] In vivo measurements of blood flow in a rat using X-ray imaging technique
    Jung, Sung Yong
    Ahn, Sungsook
    Nam, Kweon Ho
    Lee, Jin Pyung
    Lee, Sang Joon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1853 - 1858
  • [4] In vivo measurements of blood flow in a rat using X-ray imaging technique
    Sung Yong Jung
    Sungsook Ahn
    Kweon Ho Nam
    Jin Pyung Lee
    Sang Joon Lee
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1853 - 1858
  • [5] The X-ray measurements of the supermirror using synchrotron radiation
    Okajima, T
    Ichimaru, S
    Tamura, K
    Haga, K
    Ogasaka, Y
    Takahashi, S
    Fukuda, S
    Kitou, H
    Gotou, A
    Tawara, Y
    Yamashita, K
    Tsusaka, Y
    Takeda, S
    Kunieda, H
    ADVANCES IN X-RAY OPTICS, 2001, 4145 : 53 - 60
  • [6] NEW METHODS FOR X-RAY IMAGING USING COMPACT SYNCHROTRON X-RAY SOURCES
    Feidenhans, R. K.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S126 - S127
  • [7] SYNCHROTRON X-RAY TOPOGRAPHY - A MULTI-STEREOSCOPIC IMAGING TECHNIQUE
    TUOMI, T
    KELHA, V
    NAUKKARINEN, K
    BLOMBERG, M
    ACTA POLYTECHNICA SCANDINAVICA-APPLIED PHYSICS SERIES, 1981, (132): : 3 - 12
  • [8] Development of an X-ray real-time stereo imaging technique using synchrotron radiation
    Hoshino, Masato
    Uesugi, Kentaro
    Pearson, James
    Sonobe, Takashi
    Shirai, Mikiyasu
    Yagi, Naoto
    JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 569 - 574
  • [9] X-RAY STRESS MEASUREMENTS WITH SYNCHROTRON RADIATION
    NEISSENDORFER, F
    ROSSA, HJ
    THIESSEN, KP
    TOLOCHKO, BP
    MYTNICHENKO, SV
    SHEROMOV, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 276 - 277
  • [10] COINCIDENCE MEASUREMENTS WITH X-RAY SYNCHROTRON SOURCES
    HAMALAINEN, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03): : 521 - 525