Quantitative evaluation of the administrated dose affecting image quality in myocardial perfusion SPECT

被引:4
|
作者
El-Gebaly, Reem H. [1 ]
Maamoun, Islam K. [2 ]
Madian, Noha G. [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Biophys, Cairo, Egypt
[2] Cairo Univ Hosp, Nucl Cardiol Dept, Intens Care Unit, Fac Med, Cairo, Egypt
关键词
99mTc-MIBI; image quality parameters; image quality; qualitative assessment; image contrast; image noise;
D O I
10.3233/XST-140443
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Myocardial perfusion imaging (MPI) can provide the valuable cardiac functions. Image quality in nuclear medicine tomography is critically dependent on the activity administered into patients. OBJECTIVE: This study was designed to evaluate the optimum injected dose of 99mTc-MIBI for quantitative assessment of image quality as compared with standard injected dose used for that purpose. METHODS: The image quality parameters (Contrast, relative noise and contrast to noise ratio) were determined in 32 patients (21 male, 11 female, age 45-60 y) with weight 60 +/- 15 kg. Patients were classified into four groups; each one consisted of 8 patients. The first group received 370 MBq, the second one received 555 MBq, the third group received 740 MBq and the last group received 925 MBq. RESULTS: Qualitative assessments of the images revealed equivalent scintigraphic patterns in all patients. There was a significant difference in the image contrast. The image contrast in the 370 MBq group was greater than other groups. The image noise between the four groups was significantly different. It increased with injected dose reduction. Contrast to noise ratio (CNR) was significantly different between 370 MBq and other groups. CONCLUSION: It is concluded that results from the first group which received 370 MBq are sufficiently similar to those of the fourth group (standard group) which received 925 MBq. Consequently, accurate estimations of differential cardiac functions are possible with the 370 MBq dose.
引用
收藏
页码:529 / 537
页数:9
相关论文
共 50 条
  • [1] Evaluation of the optimal administrated activity in gated myocardial perfusion SPECT
    Madian, Noha G.
    Maamoun, Islam
    Yasin, Hossam
    El-Gebaly, Reem H.
    GENERAL PHYSIOLOGY AND BIOPHYSICS, 2020, 39 (06) : 587 - 593
  • [2] Image quality survey and evaluation of myocardial perfusion SPECT:: a national study
    Ohlson, M.
    Gretarsdottir, J.
    Olsson, E.
    Johansson, L.
    Gustafsson, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S164 - S165
  • [3] Evaluation of the administrated dose and image quality of pediatric patients
    Kertesz, H.
    Traub-Weidinger, T.
    Rausch, I.
    Beyer, T.
    Cal-Gonzalez, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S80 - S80
  • [4] Quantitative myocardial perfusion SPECT
    Benjamin M. W. Tsui
    Eric C. Frey
    Karen J. LaCroix
    David S. Lalush
    William H. McCartney
    Michael A. King
    Grant T. Gullberg
    Journal of Nuclear Cardiology, 1998, 5 : 507 - 522
  • [5] Quantitative myocardial perfusion SPECT
    Tsui, BMW
    Frey, EC
    LaCroix, KJ
    Lalush, DS
    McCartney, WH
    King, MA
    Gullberg, GT
    JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (05) : 507 - 522
  • [6] Comparisons of image quality according to the matrix in myocardial perfusion SPECT
    Hyeon, Jun Ho
    Lim, Jung Jin
    Shin, Byung Ho
    Kim, Tae Yeob
    Kim, Seung Jeong
    Woo, Jae Ryong
    Oh, So Won
    Kim, Yu Kyeong
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [7] Comparisons of image quality according to the matrix in myocardial perfusion SPECT
    Hyeon, Jun Ho
    Lim, Jung Jin
    Shin, Byung Ho
    Kim, Tae Yeob
    Kim, Seung Jeong
    Woo, Jae Ryong
    Oh, So Won
    Kim, Yu Kyeong
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Effect of detector energy response on image quality of myocardial perfusion SPECT
    Volokh, Lana
    Hugg, James
    Blevis, Ira
    Asma, Evren
    Jansen, Floris
    Manjeshwar, Ravindra
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3318 - +
  • [9] Influence of reconstruction algorithms on image quality in SPECT myocardial perfusion imaging
    Davidsson, Anette
    Olsson, Eva
    Engvall, Jan
    Gustafsson, Agnetha
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (06) : 655 - 662
  • [10] Three-dimensional image reconstruction methods for quantitative myocardial perfusion SPECT
    Tsui, BMW
    Frey, EC
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 502 - 505