摘要
Purpose: The purpose of this study was to investigate and compare microleakage of prefabricated posterior NuSmile (R) ZR and EZCrowns when cemented with BioCem and Ketac Cem dental cements. Methods: Forty extracted permanent teeth (N equals 10 per group) were fitted for either NuSmile or EZCrowns prefabricated posterior zirconia crowns and cemented with BioCem or Ketac Cem, for a total of four groups. Crowned teeth were placed in Dulbecco's Phosphate Buffered Saline solution at 37 degrees Celsius for 24 hours. Teeth were thermocycled between five degrees Celsius and 55 degrees Celsius for 6,000 cycles, stained with two percent basic fuchsin, sectioned, and visually inspected for microleakage utilizing stereomicroscopy on a four-point scale. Data were statistically analyzed using one-way analysis of variance, SNK (P<.05). Results: All samples in this study had microleakage. NuSmile (R) ZR crowns demonstrated significantly less microleakage when cemented with BioCem and compared to Ketac Cem (P=.002). NuSmile (R) ZR cemented with BioCem had significantly less microleakage compared to EZ-Crowns with Ketac Cem (P=.002). Conclusions: In this in vitro investigation, BioCem cement had significantly less microleakage in zirconia pre-fabricated crowns compared to Ketac Cem, and NuSmile (R) ZR crowns cemented with BioCem resulted in significantly less microleakage than EZ-Crowns cemented with Ketac Cem.
引用
收藏
页码:136 / 139
页数:4
相关论文
共 50 条
  • [1] Microleakage of luting cements in CAD/CAM pediatric zirconia crowns: an in vitro study
    Iampinitkul, Sukitta
    Chaijareenont, Pisaisit
    Chinadet, Wannapa
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [2] Evaluation of Microleakage Using Different Luting Cements in Kedo Zirconia Crowns: An In Vitro Assessment
    Vishnu, Guru
    Jeevanandan, Ganesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [3] Marginal Microleakage of Monolithic Zirconia Crowns Using Different Marginal Cement Space Thickness and Luting Cements
    Nayyef, Muthanna Ibrahim
    Ibraheem, Adel Farhan
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (07): : 17 - 22
  • [4] Factors influencing preformed metal crowns and prefabricated zirconia crowns
    Deng, Shuman
    Dou, Weiwei
    Chen, Ying
    Chen, Zhixiao
    Song, Ning
    Gao, Qi
    Zhang, Li
    Xie, Jing
    BMC ORAL HEALTH, 2025, 25 (01):
  • [5] IN-VIVO MICROLEAKAGE OF LUTING CEMENTS FOR CAST CROWNS
    WHITE, SN
    YU, ZK
    TOM, JFMD
    SANGSURASAK, S
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (04): : 333 - 338
  • [6] Microleakage of Adhesive and Nonadhesive Luting Cements for Stainless Steel Crowns
    Memarpour, Mahtab
    Mesbahi, Maryam
    Rezvani, Gita
    Rahimi, Mehran
    PEDIATRIC DENTISTRY, 2011, 33 (07) : 501 - 504
  • [7] Microleakage of Procera AllCeram Crowns with different types of cements.
    Albert, F
    El-Mowafy, O
    Zarb, G
    Watson, P
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A239 - A239
  • [8] Marginal adaptation and microleakage of Procera AllCeram crowns with four cements
    Albert, FE
    El-Mowafy, O
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2004, 17 (05) : 529 - 535
  • [9] Correlation between Microleakage and Absolute Marginal Discrepancy in Zirconia Crowns Cemented with Four Resin Luting Cements: An In Vitro Study
    Cristian, Abad-Coronel
    Jeanette, Li
    Francisco, Martnez-Rus
    Guillermo, Pradies
    INTERNATIONAL JOURNAL OF DENTISTRY, 2016, 2016
  • [10] Comparative study of the marginal microleakage of six cements in fixed provisional crowns
    Baldissara, P
    Comin, G
    Martone, F
    Scotti, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (04): : 417 - 422