Analysis of neutron and photon calibration of plastic (BC-420) and detection position for the liquid (BC-501) scintillators

被引:53
|
作者
Pozzi, SA [1 ]
Mullens, JA [1 ]
Mihalczo, JT [1 ]
机构
[1] Oak Ridge Natl Lab, Nucl Sci & Technol Div, Oak Ridge, TN 37831 USA
关键词
scintillation detector; calibration; neutron detection; photon detection; Monte Carlo;
D O I
10.1016/j.nima.2003.12.036
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we present the results of the neutron and photon calibration of a BC-420 plastic scintillator and a BC-501 liquid scintillator using a set of reference gamma sources and a Cf-252 source. The position of neutron and photon interactions inside the scintillators as a function of energy is investigated by Monte Carlo simulation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 8 条
  • [1] Neutron detection and γ-ray suppression using artificial neural networks with the liquid scintillators BC-501A and BC-537
    Soderstrom, P-A
    Jaworski, G.
    Dobon, J. J. Valiente
    Nyberg, J.
    Agramunt, J.
    de Angelis, G.
    Carturan, S.
    Egea, J.
    Erduran, M. N.
    Erturk, S.
    de France, G.
    Gadea, A.
    Goasduff, A.
    Gonzalez, V
    Hadynska-Klek, K.
    Huyuk, T.
    Modamio, V
    Moszynski, M.
    Di Nitto, A.
    Palacz, M.
    Pietralla, N.
    Sanchis, E.
    Testov, D.
    Triossi, A.
    Wadsworth, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 916 : 238 - 245
  • [2] Calibration of BC501A liquid scintillator cells with monochromatic neutron beams
    Arneodo, F.
    Benetti, P.
    Bettini, A.
    di Tigliole, A.Borio
    Calligarich, E.
    Carpanese, C.
    Casagrande, F.
    Cavalli, D.
    Cavanna, F.
    Cennini, P.
    Centro, S.
    Cesana, A.
    Chen, C.
    Chen, Y.B.
    Cline, D.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 418 (2-3): : 285 - 299
  • [3] Calibration of BC501A liquid scintillator cells with monochromatic neutron beams
    Arneodo, F
    Benetti, P
    Bettini, A
    di Tigliole, AB
    Calligarich, E
    Carpanese, C
    Casagrande, F
    Cavalli, D
    Cavanna, F
    Cennini, P
    Centro, S
    Cesana, A
    Chen, C
    Chen, YB
    Cline, D
    Consorte, O
    De Mitri, I
    Dolfini, R
    Ferrari, A
    Berzolari, AG
    He, KL
    Huang, XP
    Li, ZH
    Lu, F
    Ma, JM
    Mannocchi, S
    Matthey, C
    Mauri, F
    Mazzone, L
    Montanari, C
    Nardo, R
    Otwinowski, S
    Parlati, S
    Pascoli, D
    Pepato, A
    Periale, L
    Piano Mortari, G
    Piazzoli, A
    Picchi, P
    Pietropaolo, F
    Rappoldi, A
    Raselli, GL
    Resconi, S
    Revol, JP
    Rossella, M
    Rossi, C
    Rubbia, C
    Sala, P
    Scannicchio, D
    Sergiampietri, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 285 - 299
  • [4] Estimation of the Number of Multiple Detections of Prompt Fission Neutrons with a Multi-Module Neutron Detector Based on the Liquid Scintillator BC-501
    Sidorova, O.V.
    Zeynalov, Sh. S.
    Bulletin of the Russian Academy of Sciences: Physics, 2024, 88 (08) : 1262 - 1266
  • [5] Calibration of neutron spectrometers based on a BC-501A liquid scintillator using the neutron-gamma coincidence method
    Iliasova, M. V.
    Shevelev, A. E.
    Khilkevitch, E. M.
    Chugunov, I. N.
    Minaev, V. B.
    Gin, D. B.
    Doinikov, D. N.
    Polunovsky, I. A.
    Naidenov, V. O.
    Kozlovskiy, M. A.
    Kudoyarov, M. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 983
  • [6] NEUTRON DETECTION EFFICIENCY FOR NE213 AND BC501 SCINTILLATORS AT ENERGIES BETWEEN 25 AND 200 MEV
    BYRD, RC
    SAILOR, WC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (03): : 494 - 500
  • [7] An artificial neural network based neutron-gamma discrimination and pile-up rejection framework for the BC-501 liquid scintillation detector
    Ronchi, E.
    Soderstrom, P-A.
    Nyberg, J.
    Sunden, E. Andersson
    Conroy, S.
    Ericsson, G.
    Hellesen, C.
    Johnson, M. Gatu
    Weiszflog, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (02): : 534 - 539
  • [8] Neutron/gamma discrimination employing the power spectrum analysis of the signal from the liquid scintillator BC501A
    Luo, X. L.
    Wang, Y. K.
    Yang, J.
    Liu, G.
    Lin, C. B.
    Hu, Q. Q.
    Peng, J. X.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 717 : 44 - 50