Long-term results (20 years) of aortic valve replacement with the standard Bjork-Shiley prosthesis.

被引:0
|
作者
Valla, J [1 ]
Langanay, T [1 ]
Corbineau, H [1 ]
Sevray, B [1 ]
Chaperon, J [1 ]
Menestret, P [1 ]
Lelong, B [1 ]
Leguerrier, A [1 ]
Rioux, C [1 ]
Logeais, Y [1 ]
机构
[1] CHU RENNES,HOP PONTCHAILLOU,LAB EPIDEMIOL & HYGIENE HOSP,F-35033 RENNES,FRANCE
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Between January 1971 and December 1978, 865 standard Bjork-Shiley prostheses (spheric or conic carbon disc) were implanted in the Department of Thoracic and Cardiovascular Surgery of the University Hospital of Rennes. Three hundred and fifty seven consecutive patients who underwent isolated aortic valve replacement were included in the study: 246 men (69 %) and 111 women (31 %) with an average age of 57.5 years (range: 24-80 years). One hundred and sixty eight patients (48 %) were in NYHA Class II, 141 (39 %) in Class III and 48 (13 %) in Class IV. The valvular disease was stenotic in 304 cases (85 %) and regurgitant in 53 cases (15 %). The hospital mortality was 35 (9.8 %). The main causes of death were cardiac (23 cases, 66 %). The long-term results contain 322 survivors of surgery (mean follow-up 12 years, follow-up rate 99 %, representing 3 726 patient-years). The actuarial survival (including hospital mortality) was 76 % at 5 years, 61 % at 10 years, 47 % at 15 years and 26 % at 20 years. The average age of the survivors at present is 71 years and 95 % are NYHA classes I or II. The causes of the 171 late fatalities were cardiac in 49 cases (1.3 % per patient-year). Death was related to the prosthesis in 32 cases (0.8 % per patient-year) : 3 endocarditis, 17 bleeding complications, 12 systemic emboli. Deaths were extracardiac in 58 cases (1.5 % per patient-year). Prosthesis-related complications were : 9 paravalvular leaks (0.2 % per patient-year), 3 dysfunctions (0.1 % per patient-year), 24 haemorrages (0.6 % per patient-year), 5 thromboembolic episodes (0.1 % per patient-year), 5 endocarditis (0.1 % per patient-year). No structural abnormalities of the prostheses were observed. The authors confirm the reliability of the standard Bjork-Shiley valve prosthesis in the aortic position and the value of the aortic valve replacement by a mechanical prosthesis even at very long term.
引用
收藏
页码:1137 / 1143
页数:7
相关论文
共 50 条
  • [1] AORTIC-VALVE REPLACEMENT BY BJORK-SHILEY PROSTHESIS - LONG-TERM RESULTS IN 268 PATIENTS
    NINET, J
    COCHET, P
    NEIDECKER, J
    BRULE, P
    GRESSIER, M
    CHAMPSAUR, G
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1988, 81 (04): : 517 - 522
  • [2] LONG-TERM RESULTS OF MITRAL-VALVE REPLACEMENT WITH BJORK-SHILEY PROSTHESIS
    BRAUN, S
    CHAMORRO, G
    DUBERNET, J
    MATURANA, G
    CASANEGRA, P
    REVISTA MEDICA DE CHILE, 1979, 107 (12) : A25 - A26
  • [3] LONG-TERM CLINICAL-RESULTS AFTER AORTIC-VALVE REPLACEMENT WITH THE BJORK-SHILEY PROSTHESIS
    LINDBLOM, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 95 (04): : 658 - 667
  • [4] LONG-TERM RESULTS OF ISOLATED AORTIC-VALVE REPLACEMENT WITH THE BJORK-SHILEY PROSTHESIS IN 596 CASES
    JEGADEN, O
    LLOJEH, K
    MONTAGNA, P
    ROSSI, R
    ADELEINE, P
    DELAYE, J
    DELAHAYE, JP
    MIKAELOFF, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1991, 84 (01): : 47 - 54
  • [5] LONG-TERM RESULTS OF AORTIC-VALVE REPLACEMENT BY BJORK-SHILEY PROSTHESIS, WITH A MORE THAN 10 YEARS FOLLOW-UP
    JEGADEN, O
    BONNEFOY, JY
    RUMOLO, A
    MIKAELOFF, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1988, 81 (03): : 277 - 283
  • [6] SHORT-TERM RESULTS WITH BJORK-SHILEY PROSTHESIS AND THE BIOPROSTHESIS FOR AORTIC-VALVE REPLACEMENT
    EGLOFF, L
    ROTHLIN, M
    TURINA, M
    KRAYENBUHL, C
    KUGELMEIER, J
    SENNING, A
    ZEITSCHRIFT FUR KARDIOLOGIE, 1979, 68 (09): : 623 - 623
  • [7] THE BJORK-SHILEY VALVE PROSTHESIS - ANALYSIS OF LONG-TERM EVOLUTION
    ALVAREZ, L
    ESCUDERO, C
    FIGUERA, D
    CASTILLOOLIVARES, JL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (05): : 1249 - 1258
  • [8] LONG-TERM CLINICAL-RESULTS AFTER MITRAL-VALVE REPLACEMENT WITH THE BJORK-SHILEY PROSTHESIS
    LINDBLOM, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 95 (02): : 321 - 333
  • [9] MONOSTRUT BJORK-SHILEY AORTIC-VALVE PROSTHESIS - MEDIUM TERM RESULTS
    CANIVET, P
    VITOUX, B
    VAHANIAN, A
    MICHEL, PL
    CORMIER, B
    SARANO, LE
    RICHAUD, C
    ACAR, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1991, 84 (01): : 57 - 62
  • [10] LONG-TERM RESULTS OF CARDIAC-VALVE REPLACEMENT WITH THE DELRIN-DISC MODEL OF THE BJORK-SHILEY VALVE PROSTHESIS
    MONTERO, CG
    RUFILANCHAS, JJ
    JUFFE, A
    BURGOS, R
    UGARTE, J
    FIGUERA, D
    ANNALS OF THORACIC SURGERY, 1984, 37 (04): : 328 - 336