A comparison of fast and conventional T2 weighted spin-echo sequences in the detection of focal liver lesions at 1.0T

被引:0
|
作者
Baudouin, CJ [1 ]
Ward, J [1 ]
Ridgway, JP [1 ]
Robinson, PJ [1 ]
机构
[1] ST JAMES UNIV HOSP,DEPT CLIN RADIOL,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
关键词
D O I
10.1016/S0009-9260(96)80004-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional and fast T2-weighted spin-echo scans obtained at 1.0 T were compared in 29 patients undergoing magnetic resonance imaging of the liver, 25 of whom had focal liver lesions, Conventional spin-echo (CSE) detected 49 of 50 lesions (98%), fast spin-echo (FSE) 45 of 50 lesions (90%), Qualitative assessment of lesion conspicuity, artefact level, and overall image quality by two radiologists showed conventional spin-echo was preferred to fast spin-echo, Lesion conspicuity was graded moderate or good in 84% of lesions on CSE compared to 73% on FSE, Artefact level was higher on FSE in 34%, equal in 61% and higher on CSE in 5%, Overall, CSE was preferred to FSE in 76% of cases, Mean lesion to liver contrast to noise ratio was significantly higher on conventional spin-echo than fast spin-echo: CSE mean 5.9, FSE mean 4.9 P < 0.05, This difference in contrast to noise ratio remained for malignant lesions, but no significant difference was present for cysts and haemangiomas. We advise careful assessment of new sequences before conventional T2-weighted spin-echo is replaced by fast T2-weighted spin-echo in the detection of focal liver lesions.
引用
收藏
页码:769 / 774
页数:6
相关论文
共 50 条
  • [1] MRI in characterisation of focal liver lesions: Comparison of T2 weighting by conventional spin-echo and turbo spin-echo sequences
    Giovagnoni, A
    Paci, E
    Valeri, G
    Ercolani, P
    Gesuita, R
    Carle, F
    Piga, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) : 589 - 595
  • [2] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393
  • [3] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [4] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [5] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [6] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [7] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [8] Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T
    Jung, G
    Krahe, T
    Kugel, H
    Gieseke, J
    Hahn, U
    Walter, C
    Lackner, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) : 341 - 347
  • [9] Comparison of conventional spin echo and gradient echo T1-weighted sequences in detection of focal pancreatic lesions
    Gallix, BP
    Bret, PM
    Atri, M
    Lecesne, R
    Reinhold, C
    RADIOLOGY, 1997, 205 : 622 - 622
  • [10] Comparison of fast turbo-spin-echo and gradient-and-spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla.
    Jung, G
    Krahe, T
    Kugel, H
    Gieseke, J
    Walter, C
    Fischbach, R
    Landwehr, P
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (02): : 137 - 143