Computational Study of the Effect of Electrode Polarity on Neural Activation Related to Paresthesia Coverage in Spinal Cord Stimulation Therapy

被引:9
|
作者
Dura, Jose L. [1 ]
Solanes, Carmen [1 ]
De Andres, Jose [2 ,3 ]
Saiz, Javier [1 ]
机构
[1] Univ Politecn Valencia, Ctr Res & Innovat Bioengn, Valencia, Spain
[2] Gen Univ Hosp, Anesthesia Crit Care & Multidisciplinary Pain Man, Valencia, Spain
[3] Valencia Univ Med Sch, Anesthesia Unit, Surg Specialties Dept, Valencia, Spain
来源
NEUROMODULATION | 2019年 / 22卷 / 03期
关键词
Computational model; dorsal column stimulation; dorsal root stimulation; electrode polarity; spinal cord stimulation; PERCEPTION THRESHOLD; INTRACTABLE PAIN; DORSAL COLUMNS; NERVE-FIBERS; FOLLOW-UP; MECHANISMS; FIELD;
D O I
10.1111/ner.12909
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
ObjectiveUsing computer simulation, we investigated the effect of electrode polarity on neural activation in spinal cord stimulation and propose a new strategy to maximize the activating area in the dorsal column (DC) and, thus, paresthesia coverage in clinical practice. Materials and MethodsA new three-dimensional spinal cord model at the T10 vertebral level was developed to simulate neural activation induced by the electric field distribution produced by different typical four-contact electrode polarities in single- and dual-lead stimulation. Our approach consisted of the combination of a finite element model of the spinal cord developed in COMSOL Multiphysics and a nerve fiber model implemented in MATLAB. Five evaluation parameters were evaluated, namely, the recruitment ratio, the perception and discomfort thresholds, and the activating area and depth. The results were compared quantitatively. ResultsThe dual-guarded cathode presents the maximum activating area and depth in single- and dual-lead stimulation. However, the lowest value of the ratio between the perception threshold in DC and the perception threshold in the dorsal root (DR) is achieved when the guarded cathode is programmed. Although the two versions of bipolar polarity (namely bipolar 1 and bipolar 2) produce higher activating area and depth than the guarded cathode, they are suitable for producing DR stimulation. Similarly, dual-lead stimulation is likely to activate DR fibers because the electrodes are closer to these fibers. ConclusionsThe results suggest that the activating area in the DC is maximized by using the dual-guarded cathode both in single- and dual-lead stimulation modes. However, DC nerve fibers are preferentially stimulated when the guarded cathode is used. According to these results, the new electrode programming strategy that we propose for clinical practice first uses the dual-guarded cathode, but, if the DR nerve fibers are activated, it then uses guarded cathode polarity.
引用
收藏
页码:269 / 279
页数:11
相关论文
共 50 条
  • [1] Effect of Lead Position and Polarity on Paresthesia Coverage in Spinal Cord Stimulation Therapy: A Computational Study
    Dura, Jose L.
    Solanes, Carmen
    De Andres, Jose
    Saiz, Javier
    NEUROMODULATION, 2022, 25 (05): : 680 - 692
  • [2] Spinal geometry and paresthesia coverage in spinal cord stimulation
    Holsheimer, J
    Barolat, G
    NEUROMODULATION, 1998, 1 (03): : 129 - 136
  • [3] Effects of electrode positioning on perception threshold and paresthesia coverage in spinal cord stimulation
    Holsheimer, Jan
    Khan, Yasin N.
    Raza, Shariq S.
    Khan, Elizabeth A.
    NEUROMODULATION, 2007, 10 (01): : 34 - 41
  • [4] The Effect of Pulse Width and Contact Configuration on Paresthesia Coverage in Spinal Cord Stimulation
    Holsheimer, Jan
    Buitenweg, Jan R.
    Das, John
    de Sutter, Paul
    Manola, Ljubomir
    Nuttin, Bart
    NEUROSURGERY, 2011, 68 (05) : 1452 - 1461
  • [5] Effect of anode-cathode configuration on paresthesia coverage in spinal cord stimulation
    Holsheimer, J
    Wesselink, WA
    NEUROSURGERY, 1997, 41 (03) : 654 - 659
  • [6] Clinical Paresthesia Atlas Illustrates Likelihood of Coverage Based on Spinal Cord Stimulation Electrode Location
    Taghva, Alexander
    Underwood, Paul
    Karst, Edward
    JOURNAL OF NEUROSURGERY, 2015, 123 (02) : A515 - A515
  • [9] Clinical Paresthesia Atlas Illustrates Likelihood of Coverage Based on Spinal Cord Stimulator Electrode Location
    Taghva, Alexander
    Karst, Edward
    Underwood, Paul
    NEUROMODULATION, 2017, 20 (06): : 582 - 588
  • [10] An Analysis of Paresthesia Areas Evoked by Spinal Cord Stimulation in Relation to the Position of Electrode Tip
    Lee, Mi Geum
    Lee, Hyo Mm
    Jo, Ji Yon
    Choi, Yun Suk
    Ku, Ui Kyoung
    Lee, Chul Joong
    Lee, Sang Chul
    Kim, Yong Chul
    KOREAN JOURNAL OF PAIN, 2006, 19 (02): : 146 - 151