Comparing neural networks and linear discriminant functions for glaucoma detection using confocal scanning laser ophthalmoscopy of the optic disc

被引:0
|
作者
Bowd, C [1 ]
Chan, K
Zangwill, LM
Goldbaum, MH
Lee, TW
Sejnowski, TJ
Weinreb, RN
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Inst Neural Computat, La Jolla, CA 92093 USA
[3] Salk Inst Biol Studies, Computat Neurobiol Labs, La Jolla, CA USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine whether neural network techniques can improve differentiation between glaucomatous and nonglaucomatous eyes, using the optic disc topography parameters of the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany). METHODS. With the HRT, one eye was imaged from each of 108 patients with glaucoma (defined as having repeatable visual field defects with standard automated perimetry) and 189 subjects without glaucoma (no visual field defects with healthy-appearing optic disc and retinal nerve fiber layer on clinical examination) and the optic nerve topography was defined by 17 global and 66 regional HRT parameters. With all the HRT parameters used as input, receiver operating characteristic (ROC) curves were generated for the classification of eyes, by three neural network techniques: linear and Gaussian support vector machines (SVM linear and SVM Gaussian, respectively) and a multilayer perceptron (MLP), as well as four previously proposed linear discriminant functions (LDFs) and one LDF developed on the current data with all HRT parameters used as input. RESULTS. The areas under the ROC curves for SVM linear and SVM Gaussian were 0.938 and 0.945, respectively; for MLP, 0.941; for the current LDF, 0.906; and for the best previously proposed LDF, 0.890. With the use of forward selection and backward elimination optimization techniques, the areas under the ROC curves for SVM Gaussian and the current LDF were increased to approximately 0.96. CONCLUSIONS. Trained neural networks, with global and regional HRT parameters used as input, improve on previously proposed HRT parameter-based LDFs for discriminating between glaucomatous and nonglaucomatous eyes. The performance of both neural networks and LDFs can be improved with optimization of the features in the input. Neural network analyses show promise for increasing diagnostic accuracy of tests for glaucoma.
引用
收藏
页码:3444 / 3454
页数:11
相关论文
共 50 条
  • [1] Glaucoma Precognition Based on Confocal Scanning Laser Ophthalmoscopy Images of the Optic Disc Using Convolutional Neural Network
    Gupta, Krati
    Goldbaum, Michael
    Yousefi, Siamak
    2021 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, CVPRW 2021, 2021, : 2259 - 2267
  • [2] Comparison of the Moorfields classification using confocal scanning laser ophthalmoscopy and subjective optic disc classification in detecting glaucoma in blacks and whites
    Girkin, Christopher A.
    DeLeon-Ortega, Julio E.
    Xie, Aiyuan
    McGwin, Gerald
    Arthur, Stella N.
    Monheit, Blythe E.
    OPHTHALMOLOGY, 2006, 113 (12) : 2144 - 2149
  • [3] Optic Disc Drusen Using Retromode Scanning Laser Ophthalmoscopy
    Ricciotti, Guido
    Miere, Alexandra
    Colantuono, Donato
    Souied, Eric H.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2024, 44 (03) : E479 - E480
  • [4] Preperimetric glaucoma diagnosis by confocal scanning laser tomography of the optic disc
    Mardin, CY
    Horn, FK
    Jonas, JB
    Budde, WM
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (03) : 299 - 304
  • [5] Comparing confocal scanning laser ophthalmoscopy measurements of the optic nerve head and peripapillary retina for detecting glaucoma using machine learning classifiers
    Zangwill, LM
    Chan, K
    Bowd, C
    Medeiros, F
    Goldbaum, MH
    Lee, TW
    Sejnowski, TJ
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U270 - U270
  • [6] Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy
    Leung, Christopher Kai-shun
    Cheng, Arthur Chak Kwan
    Chong, Kelvin Kam Lung
    Leung, King Sai
    Mohamed, Shaheeda
    Lau, Charles Sing Lok
    Cheung, Carol Yim Lui
    Chu, Geoffrey Chin-hung
    Lai, Ricky Yiu Kwong
    Pang, Calvin Chi Pui
    Lam, Dennis Shun Chiu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) : 3178 - 3183
  • [7] Discriminant analysis models using confocal scanning laser ophthalmoscopy measurements in Latinos
    Doi, LM
    Melo, LA
    Fasolo, LR
    Barbosa, AS
    Mello, PAA
    Prata, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [8] Specifity of Optic Disc Evaluation in Healthy Subjects with Large Optic Discs and Physiologic Cupping Using Confocal Scanning Laser Ophthalmoscopy
    Plange, N.
    Hirsch, T.
    Bienert, M.
    Remky, A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2014, 231 (02) : 164 - 169
  • [9] Asymmetry in optic disc morphometry as measured by confocal scanning laser ophthalmoscopy in subjects with hyperopic anisometropia
    Bozkurt, Banu
    Irkec, Murat
    Arslan, Umut
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2008, 45 (03) : 156 - 160
  • [10] Optic Disc Progression in Glaucoma: Comparison of Confocal Scanning Laser Tomography to Optic Disc Photographs in a Prospective Study
    Chauhan, Balwantray C.
    Hutchison, Donna M.
    Artes, Paul H.
    Caprioli, Joseph
    Jonas, Jost B.
    LeBlanc, Raymond P.
    Nicolela, Marcelo T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (04) : 1682 - 1691