Influence of Single-file Endodontics on Apical Transportation in Curved Root Canals: An Ex Vivo Micro-Computed Tomographic Study

被引:23
|
作者
Junaid, Alanna [1 ]
Freire, Laila Gonzales [2 ]
da Silveira Bueno, Carlos Eduardo [3 ]
Mello, Isabel [4 ]
Cunha, Rodrigo Sanches [4 ]
机构
[1] Univ Manitoba, Winnipeg, MB R3E 0W2, Canada
[2] Univ Sao Paulo, Sao Paulo, Brazil
[3] Sao Leopoldo Mand, Dent Res Ctr, Campinas, SP, Brazil
[4] Univ Manitoba, Dept Restorat Dent, Winnipeg, MB R3E 0W2, Canada
关键词
Continuous rotating motion; micro-computed tomography; reciprocating motion; root canal preparation; transportation; NICKEL-TITANIUM ALLOY; CYCLIC FATIGUE LIFE; TWISTED FILES; MECHANICAL-PROPERTIES; SHAPING ABILITY; PROTAPER SYSTEM; ROTARY; INSTRUMENTS; PROFILE;
D O I
10.1016/j.joen.2013.09.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: More information regarding the ability of single files to maintain the original canal position is required before adopting a single-file approach to cleaning and shaping. This study compares apical transportation in curved root canals when instrumenting with a single Wave One (WO) file (Dentsply Tulsa Dental Specialties, Tulsa, OK) in a reciprocating motion with that incurred when using a sequence of Twisted Files (TFs; SybronEndo, Orange, CA) in a continuous rotating motion. Methods: Forty mesial canals of mandibular molars were evenly allocated into 2 balanced groups (n=20) with a 17-mm average canal length and 200 average curvature. Canals were accessed in a conventional manner and instrumentation was completed. with a single WO file or a series of TFs. The canals were instrumented according to the manufacturers' protocol: Apical transportation was assessed on a comparison of the pre- and postinstrumentation micro computed tomographic scans at 1-, 2-, 3-, 4-, and 5-mm sections. One-way analysis of variance was performed to assess if a significant difference between systems exists. Results: No significant difference (P>.05) was found between the WO and TF groups. Transportation in the mesial direction was of greater magnitude than distal transportation for both files systems. The mean transportation in the mesial direction was 100.1 +/- 8.8 mu m (WO group) and 101.0 +/- 10.9 mu m (TF group) (P=.5), whereas distal transportation was found to be 80.9 +/- 14.6 mu m (WO group) and 60.3 +/- 11.0 mu m (TF group) (P=.3). Conclusions: The results suggest that no difference exists between the WO file system and the conventional multifile TF system when considering apical transportation in curved canals.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 50 条
  • [1] Apical transportation using Mtwo or Reciproc retreatment systems in severely curved canals: a micro-computed tomographic study
    Isabelle L. L. Gomes
    Flávio R. F. Alves
    Marília F. Marceliano-Alves
    Stephanie B. Silveira
    Júlio Cézar N. Sousa
    José Claudio Provenzano
    Lucio Souza Gonçalves
    Clinical Oral Investigations, 2023, 27 : 1235 - 1241
  • [2] Comparison of five single-file systems in the preparation of severely curved root canals: an ex vivo study
    Liu, Yina
    Chen, Meizhi
    Tang, Weilong
    Liu, Chang
    Du, Minquan
    BMC ORAL HEALTH, 2022, 22 (01)
  • [3] Apical transportation using Mtwo or Reciproc retreatment systems in severely curved canals: a micro-computed tomographic study
    Gomes, Isabelle L. L.
    Alves, Flavio R. F.
    Marceliano-Alves, Marilia F.
    Silveira, Stephanie B.
    Sousa, Julio Cezar N.
    Provenzano, Jose Claudio
    Goncalves, Lucio Souza
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (03) : 1235 - 1241
  • [4] Comparison of five single-file systems in the preparation of severely curved root canals: an ex vivo study
    Yina Liu
    Meizhi Chen
    Weilong Tang
    Chang Liu
    Minquan Du
    BMC Oral Health, 22
  • [5] Micro-computed Tomographic Evaluation of the Shaping Ability of 3 Reciprocating Single-File Nickel-Titanium Systems on Single- and Double-Curved Root Canals
    Haupt, Franziska
    Pult, Jonas Robert Wilhelm
    Huelsmann, Michael
    JOURNAL OF ENDODONTICS, 2020, 46 (08) : 1130 - 1135
  • [6] Canal transportation using Mani GPR or HyFlex NT during the retreatment of curved root canals: A micro-computed tomographic study
    Gomes, Isabelle Luise Lima
    Alves, Flavio Rodrigues Ferreira
    Marceliano-Alves, Marilia F.
    Silveira, Stephanie B.
    Provenzano, Jose Claudio
    Goncalves, Lucio Souza
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (01) : 73 - 80
  • [7] Comparative Evaluation of Root Canal Transportation by Three NiTi Single-File Systems in Curved Canals: A Cone Beam Computed Tomography Study
    Saberi, Eshaghali
    Farhad-Mollashahi, Narges
    Bijari, Shima
    Daryaeian, Mohammad
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [8] Micro-computed Tomographic Assessment of the Residual Filling Volume, Apical Transportation, and Crack Formation after Retreatment with Reciproc and Reciproc Blue Systems in Curved Root Canals
    Kirici, Damla
    Demirbuga, Sezer
    Karatas, Ertugrul
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 238 - 243
  • [9] Evaluation of the Efficacy of TRUShape and Reciproc File Systems in the Removal of Root Filling Material: An Ex Vivo Micro-Computed Tomographic Study
    Zuolo, Arthur de Siqueira
    Zuolo, Mario Luis
    da Silveira Bueno, Carlos Eduardo
    Chu, Rene
    Cunha, Rodrigo Sanches
    JOURNAL OF ENDODONTICS, 2016, 42 (02) : 315 - 319
  • [10] Micro-computed tomographic evaluation of the shaping ability of four instrumentation systems in curved root canals
    Stringheta, C. P.
    Bueno, C. E. S.
    Kato, A. S.
    Freire, L. G.
    Iglecias, E. F.
    Santos, M.
    Pelegrine, R. A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (06) : 908 - 916