Analysis of Termination Impedance Influence to Radiated Emission from AC Cable with CMAD

被引:0
|
作者
Kuwabara, Nobuo [1 ]
Nakanishi, Takuto [1 ]
Osabe, Kunihiro [2 ]
Muramatsu, Hidenori [3 ]
机构
[1] Kyushu Inst Technol, Dept Elect & Elect Engn, Kitakyushu, Fukuoka 804, Japan
[2] Voluntary EMC Lab Accreditat Ctr, Accreditat Operat, Dept, Tokyo, Japan
[3] VCCI Council, Tokyo, Japan
来源
2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE) | 2014年
关键词
radiated disturbance test; AC cable; CMAD; equivalent circuit; common-mode current;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The method of stabilizing termination impedance at AC cables is discussed to improve the reproducibility of test results between test sites. The common-mode absorbing device (CMAD) and the VHF band line impedance stabilization network (VHF-LISN) were investigated as the devices which can stabilize the termination impedance, and the investigation indicated that the deviation between test sites depended on the type of equipment when CMAD was used as the device. The phenomenon was studied by connecting the artificial network (AN) to the AC cable end. Comb generator and PC were used for the study as EUT. The termination impedance of the AC cable was changed by the AN, and then, the radiated electric field strength and the common-mode current were measured. The investigation indicated that the standard deviation of the field strength is similar to that of the common-mode current. The AC cable with CMAD and the AN were presented by an equivalent circuit, and the circuit parameters were determined from the measurement value of S-parameters. The equivalent circuit and disturbance sources of EUT were determined from the measured currents intensity and S-parameters. The common-mode current was calculated when the termination impedance of the AC cable was changed, and the standard deviation of the common-mode current was estimated. The comparison with the measurement value showed that the type of EUT influenced the deviation between test sites.
引用
收藏
页码:807 / 812
页数:6
相关论文
共 50 条
  • [1] Influence of Termination Impedance to Radiated Emission from AC Cable with Ferrite Cores Array below 300 MHz
    Kuwabara, Nobuo
    Nakanishi, Takuto
    Osabe, Kunihiro
    Muramatsu, Hidenori
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, TOKYO (EMC'14/TOKYO), 2014, : 263 - 266
  • [2] Termination Impedance for AC Mains Cable Leaving from EUT Area in Radiated Emission Measurement
    Osabe, Kunihiro
    Kuwabara, Nobuo
    Okuyama, Shinichi
    2017 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2017,
  • [3] Influence of interface cables termination impedance on radiated emission measurement
    Bittera, M.
    Smiesko, V.
    MEASUREMENT SCIENCE REVIEW, 2010, 10 (05): : 157 - 161
  • [4] Enhance the Test Reproducibility of Radiated Emission by Defined Cable Termination
    Lee, Bor-Lin
    Wang, Yi-Wei
    Wang, J-P
    2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2012, : 446 - 450
  • [5] Investigation on Differrence of Radiated Emission Measurement Reproducibility between two EUTs at International RRT by Using CMAD as a Terminating Device for AC Mains Cable
    Okuyama, Shinichi
    Kuwabara, Nobuo
    Osabe, Kunihiro
    Muramatsu, Hidenori
    2018 IEEE SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL INTEGRITY AND POWER INTEGRITY (EMC, SI & PI), 2018, : 516 - 521
  • [6] Radiated emission from a PCB with an attached cable resulting from a nonzero ground plane impedance
    Kayano, Y
    Tanaka, M
    Inoue, H
    EMC 2005: IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1-3, PROCEEDINGS, 2005, : 955 - 960
  • [7] Analysis of the Radiated Emission from the ESD Generator return cable.
    Salil, P.
    Albin, A.
    Subbarao, B.
    INCEMIC 2008: 10TH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY, PROCEEDINGS, 2008, : 429 - 431
  • [8] Investigating Power Line Termination Device Effectiveness in Regards to Radiated Emission Measurement Reproducibility in Consideration of Two Disturbance Sources and AC Mains Cable
    Okuyama, Shinichi
    Osabe, Kunihiro
    Kuwabara, Nobuo
    Amemiya, Fujio
    Shimasaki, Toshiki
    Muramatsu, Hidenori
    PROCEEDINGS OF THE 2020 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2020,
  • [9] Investigation into the Influence of Ground Plane Insulation Thickness on Radiated Emission from Mains Cable of EUT
    Okuyama, Shinichi
    Kuwabara, Nobuo
    Miyata, Kuniyuki
    Osabe, Kunihiro
    2017 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2017, : 35 - 37
  • [10] Acoustic emission from partial discharges in cable termination
    Czaszejko, Tadeusz
    Sookun, Jonathan
    Proceedings of the International Symposium on Electrical Insulating Materials, 2014, : 42 - 45