New Bioabsorbable Septal Repair Implant for Percutaneous Closure of a Patent Foramen Ovale: Short-Term Results of a Single-Centre Experience

被引:10
|
作者
Van den Branden, B. J. L. [1 ]
Post, M. C. [1 ]
Jaarsma, W. [1 ]
ten Berg, J. M. [1 ]
Suttorp, M. J. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3435 CM Nieuwegein, Netherlands
关键词
congenital heart defect; catheterization; efficacy; TRANSCATHETER CLOSURE; PARADOXICAL EMBOLISM; FOLLOW-UP; DEVICE; OCCLUDER; AMPLATZER; EVENTS; STROKE; RISK; COMPLICATIONS;
D O I
10.1002/ccd.21998
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Permanent implants for closure of a patent foramen ovale (PFO) have a number of possible disadvantages including erosions, thrombus formation, and allergic reactions. The incidence of adverse events may be lower using a bioabsorbable device. Objective: To evaluate the short-term safety and efficacy of a new bioabsorbable closure device. Methods: All 35 consecutive patients (21 female, mean age 47.9 +/- 10.8 years), who underwent a percutaneous PFO closure between November 2007 and July 2008, were included. All complications were reported. The efficacy was based on the residual shunting the day after implant and at 1 month follow-up and was graded as minimal, moderate, or severe, using contrast transthoracic echocardiography with the Valsalva manoeuvre. Results: The only in-hospital complication was a surgical device retrieval from the femoral vein. Four patients developed a minimal inguinal haematoma. One day after closure, residual shunting was present in 56% of the patients (minimal 27%, moderate 23% and severe 6%). At I month follow-up (n = 33), one patient developed a transient neurological deficit and three patients suffered from paroxysmal atrial fibrillation. A residual shunt at 1 month was present in 45% of the patients (minimal 30%, moderate 12%, and severe 3%). Conclusions: Percutaneous PFO closure using the bioabsorbable closure device seems to be safe. However, a high rate of residual shunting is present at 1 month follow-up. Long-term follow-up data are necessary to evaluate the efficacy and safety of this device. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 50 条
  • [1] New bioabsorbable septal repair implant for percutaneous closure of a patent foramen ovale: short-term results of a single-centre experience
    Van den Branden, B. J. L.
    Post, M. C.
    Jaarsma, W.
    Ten Berg, J. M.
    Suttorp, M. J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 579 - 579
  • [2] New Bioabsorbable Septal Repair Implant for Percutaneous Closure of a Patent Foramen Ovale : Short-Term Results of a Single-Centre Experience
    Van den Branden, Ben J.
    Ten Berg, Jurien M.
    Suttorp, Maarten-Jan
    Post, Marco
    Jaarsma, Wybren
    CIRCULATION, 2008, 118 (18) : S808 - S808
  • [3] Percutaneous Closure of Patent Foramen Ovale with a Bioabsorbable Occluder Device: Single-Centre Experience
    Ussia, Gian Paolo
    Cammalleri, Valeria
    Mule, Massimiliano
    Scarabelli, Marilena
    Barbanti, Marco
    Scardaci, Francesco
    Mangiafico, Sarah
    Imme, Sebastiano
    Capodanno, Davide
    Tamburino, Corrado
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (04) : 607 - 614
  • [4] One year efficacy of patent foramen ovale closure using the new bioabsorbable septal repair implant
    Van Den Branden, B.
    Post, M. C.
    Plokker, H. W. M.
    Ten Berg, J. M.
    Suttorp, M. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 316 - 316
  • [5] Percutaneous closure of Patent Foramen Ovale (PFO) and atrial septal defect (ASD): A single centre experience and results
    Egred, M.
    Andron, M.
    Albouaini, K.
    Alahmar, A.
    Grainger, R.
    Grayson, A.
    Morrison, W. L.
    EUROPEAN HEART JOURNAL, 2006, 27 : 803 - 804
  • [6] Mid-term Safety and Efficacy of Patent Foramen Ovale Closure Using the Bioabsorbable Septal Repair Implant
    Van den Branden, Ben
    Post, Marco
    ten Berg, Jurrien
    Suttorp, Maarten-Jan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A18 - A19
  • [7] Initial single-centre experience with the intrasept articulating device for percutaneous closure of the patent foramen ovale
    Budts, W
    Loockx, N
    Van de Werf, F
    EUROPEAN HEART JOURNAL, 2004, 25 : 201 - 201
  • [8] Percutaneous closure of patent foramen ovale for hypoxemia: a single-centre retrospective study
    Vermeersch, Gaelle
    Verheye, Stefan
    Scott, Benjamin
    Convens, Carl
    Vermeersch, Paul
    ACTA CARDIOLOGICA, 2017, 72 (01) : 107 - 107
  • [9] Bioabsorbable Occluder Device for Percutaneous Closure of Patent Foramen Ovale: Single Center Experience
    Ussia, GianPaolo
    Cammalleri, Valeria
    Scardaci, Francesco
    Scarabelli, Marilena
    Imme, Sebastiano
    Barbanti, Marco
    Mule, Massimiliano
    Mangiafico, Sarah
    Marchese, Anna
    Tamburino, Corrado
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 28D - 29D
  • [10] Percutaneous closure of a patent foramen ovale: single-centre experience using different types of devices and mid-term outcome
    Post, MC
    Van Deyk, K
    Budts, W
    ACTA CARDIOLOGICA, 2005, 60 (05) : 515 - 519