Prosthetic valve endocarditis due to Actinobacillus actinomycetemcomitans:: a review of 36 cases

被引:0
|
作者
Cobo, F [1 ]
Manchado, P [1 ]
Enciso, MD [1 ]
机构
[1] Hosp Univ Carlos Haya, Serv Clin Microbiol, Malaga 29010, Spain
关键词
Actinobacillus actinomycetemcomitans; endocarditis; prosthetic valve;
D O I
10.1097/01.revedmi.0000131422.82858.e7
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Actinobacillus actinomycetemcomitans has been reported to be a possible aetiologic agent in late prosthetic valve endocarditis. There have been 33 cases reported in whom endocarditis occurred a year or more after implantation of the prosthesis. Of 36 patients reviewed here, 21 had undergone dental alterations or dental work recently. The final outcome was satisfactory in 23 patients; congestive heart failure occurred in three cases and valve replacement was necessary in the other eight patients. Although the optimal antimicrobial therapy for endocarditis due to A. actinomycetemcomitans is not known, third generation cephalosporins should be considered as the drugs of choice. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:7 / 15
页数:9
相关论文
共 50 条
  • [1] Oral ciprofloxacin therapy prosthetic valve endocarditis due to Actinobacillus actinomycetemcomitans
    Babinchak, TJ
    CLINICAL INFECTIOUS DISEASES, 1995, 21 (06) : 1517 - 1518
  • [2] ACTINOBACILLUS-ACTINOMYCETEMCOMITANS PROSTHETIC VALVE ENDOCARDITIS
    GRACE, CJ
    LEVITZ, RE
    KATZPOLLAK, H
    BRETTMAN, LR
    REVIEWS OF INFECTIOUS DISEASES, 1988, 10 (05): : 922 - 929
  • [3] ENDOCARDITIS DUE TO ACTINOBACILLUS-ACTINOMYCETEMCOMITANS OF BOTH A PROSTHETIC VALVE AND A NATIVE VALVE IN THE SAME PATIENT
    WILSON, JH
    FRANCO, I
    KEYS, TF
    CLEVELAND CLINIC QUARTERLY, 1986, 53 (02): : 193 - 195
  • [4] ACTINOBACILLUS ACTINOMYCETEMCOMITANS ENDOCARDITIS IN A PATIENT WITH A PROSTHETIC AORTIC-VALVE
    PANWALKER, AP
    AKALIN, HE
    ZIMELIS, V
    JACKSON, GG
    INFECTION, 1977, 5 (02) : 104 - 106
  • [5] INFECTIVE ENDOCARDITIS DUE TO ACTINOBACILLUS-ACTINOMYCETEMCOMITANS IN A PATIENT WITH A PORCINE PROSTHETIC MITRAL-VALVE
    LALONDE, G
    HAND, R
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1980, 122 (03) : 316 - 319
  • [6] PROSTHETIC VALVE ENDOCARDITIS AND PARAVALVULAR ABSCESS CAUSED BY ACTINOBACILLUS-ACTINOMYCETEMCOMITANS
    WILSON, ME
    REVIEWS OF INFECTIOUS DISEASES, 1989, 11 (04): : 665 - 667
  • [7] ENDOCARDITIS DUE TO ACTINOBACILLUS ACTINOMYCETEMCOMITANS
    UNDERHILL, EE
    CANADIAN JOURNAL OF MEDICAL TECHNOLOGY, 1968, 30 (03): : 125 - +
  • [8] ENDOCARDITIS DUE TO ACTINOBACILLUS ACTINOMYCETEMCOMITANS
    MACKLON, AF
    INGHAM, HR
    SELKON, JB
    EVANS, JG
    BRITISH MEDICAL JOURNAL, 1975, 1 (5958): : 609 - 610
  • [9] ACTINOBACILLUS PROSTHETIC VALVE ENDOCARDITIS
    HAMORI, PJ
    SLAMA, TG
    AMERICAN HEART JOURNAL, 1989, 118 (04) : 853 - 854
  • [10] ENDOCARDITIS DUE TO ACTINOBACILLUS-ACTINOMYCETEMCOMITANS
    CHOWDHURY, MNH
    ALNOZHA, M
    HUSAIN, IS
    AKHTAR, J
    JOURNAL OF INFECTION, 1985, 10 (02) : 158 - 162