Ion chromatographic behaviour and determination of perbromates

被引:4
|
作者
Megoulas, NC [1 ]
Koupparis, MA [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, Athens 15771, Greece
关键词
perbromate; phenate; ion chromatography; conductimetric detection;
D O I
10.1016/j.aca.2004.01.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion chromatographic behaviour of perbromates in aqueous solutions was studied, using ion suppressed conductimetric detection (Dionex DX-100 ion chromatograph with ASRS-I suppressor). Various eluents (sodium hydroxide, carbonate and phenate solutions) were examined using the AS-144 mm x 250 mm anion-exchange column and an optimization study concerning pH and total eluate concentration of mobile phase was carried out. Phenate buffer (20.0 mM, pH 11.0) at 1.18 ml/min flow rate, gave the best results. Calibration curve was linear in the range of 1.5-200ppm. with a limit of detection of 0.46ppm and R.S.D. 1.8% (100 ppm standard). Perbromates were separated with good resolution from potentially interfering anions (bromides, bromates, iodides, perchlorates). Selectivity coefficients were determined for perbromates. perchlorates and iodides, from linear plots of retention volume versus the reciprocal of eluent concentration. The new method was used to monitor the perbromate reactions with lactic acid, iodide and citric acid in the absence and presence of Fe(II) acting as an inducer. Furthermore. it was confirmed the inability of various common strong oxidative media to oxidize bromate to perbromate. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF PERBROMATES BY POTENTIOMETRIC TITRATION
    BRAND, JR
    SMITH, ML
    ANALYTICAL CHEMISTRY, 1971, 43 (08) : 1105 - &
  • [2] Ion chromatographic determination of acidity
    De Borba, BM
    Kinchin, CM
    Sherman, D
    Cook, TK
    Dasgupta, PK
    Srinivasan, K
    Pohl, CA
    ANALYTICAL CHEMISTRY, 2000, 72 (01) : 96 - 100
  • [3] Ion chromatographic determination of thyroxine in urine
    Bhavana, L
    Ajimon, VJ
    Radhika, SL
    Sindhu, M
    Iyer, CSP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 803 (02): : 363 - 366
  • [4] ION CHROMATOGRAPHIC DETERMINATION OF ANIONS IN RAINWATER
    OIKAWA, K
    SAITO, H
    CHEMOSPHERE, 1982, 11 (09) : 933 - 941
  • [5] ION CHROMATOGRAPHIC DETERMINATION OF SODIUM ISETHIONATE
    IANNIELLO, RM
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (11): : 2305 - 2314
  • [6] ION CHROMATOGRAPHIC DETERMINATION OF SULFITES IN FOODS
    ANDERSON, C
    WARNER, CR
    DANIELS, DH
    PADGETT, KL
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1986, 69 (01): : 14 - 19
  • [7] ON THE ION CHROMATOGRAPHIC DETERMINATION OF S(IV)
    DASGUPTA, PK
    ATMOSPHERIC ENVIRONMENT, 1982, 16 (05) : 1265 - 1268
  • [8] ION CHROMATOGRAPHIC DETERMINATION OF BROMATE IN BREAD
    OIKAWA, K
    SAITO, H
    SAKAZUME, S
    FUJII, M
    BUNSEKI KAGAKU, 1982, 31 (08) : E251 - E255
  • [9] ION CHROMATOGRAPHIC DETERMINATION OF ANIONS IN WASTEWATER PRECIPITATE
    GREEN, LW
    WOODS, JR
    ANALYTICAL CHEMISTRY, 1981, 53 (14) : 2187 - 2189
  • [10] ION-CHROMATOGRAPHIC DETERMINATION OF PHOSPHATES IN CASTABLES
    WANG, YQ
    ZHAO, GL
    GU, MT
    JIANG, S
    YAN, ZY
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (10): : 700 - 702