Analysis of microcystins using high-performance liquid chromatography and magnetic solid-phase extraction with silica-coated magnetite with cetylpyridinium chloride

被引:19
|
作者
Li, Qiuying [1 ]
Lian, Lili [1 ]
Wang, Xiyue [1 ]
Wang, Runnan [1 ]
Tian, Yuanyuan [1 ]
Guo, Xiaoyang [1 ]
Lou, Dawei [1 ]
机构
[1] Jilin Inst Chem Technol, Dept Analyt Chem, 45 Chengde St, Jilin 132022, Peoples R China
基金
中国国家自然科学基金;
关键词
high-performance liquid chromatography; magnetic solid-phase extraction; magnetite; microcystins; POLYCYCLIC AROMATIC-HYDROCARBONS; ENVIRONMENTAL WATER; EFFICIENT ENRICHMENT; PORE-WALLS; NANOPARTICLES; MICROSPHERES; SAMPLES; CORE; LR; MICROEXTRACTION;
D O I
10.1002/jssc.201601407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microcystins (MCs), produced by freshwater cyanobacteria, can be serious water pollutants, so it is important to monitor their concentration in drinking water. We have developed a method for rapid and accurate determination of microcystin levels in environmental water, using magnetic solid-phase extraction and high-performance liquid chromatography with UV detection. The magnetic composite material, which was combined with cetylpyridinium chloride, was prepared by hydrothermal synthesis. The optimal extraction of microcystins in water sample was achieved by optimizing the amount of adsorbent, time of adsorption, ratio of eluting solvent, and volume of eluent. Under the optimal conditions, the limit of detection of MC-LR was 0.001 mu g/L, and the limit of quantification was 0.0028 mu g/L. The limit of detection of MC-RR was 0.001 mu g/L, and the limit of quantification was 0.003 mu g/L. These values are far lower than those established by the International Health Organization for the maximum concentration of microcystins in drinking water. The magnetic solid-phase extraction adsorbent used in this method has the advantages of simple preparation, low price, and easy solid-liquid separation, and it can be used for the rapid and sensitive monitoring of trace microcystins in environmental water samples.
引用
收藏
页码:1644 / 1650
页数:7
相关论文
共 50 条
  • [1] Cetylpyridinium chloride functionalized silica-coated magnetite microspheres for the solid-phase extraction and pre-concentration of ochratoxin A from environmental water samples with high-performance liquid chromatographic analysis
    Hu, Meihua
    Huang, Pengcheng
    Suo, Lili
    Wu, Fangying
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (11) : 2431 - 2437
  • [2] Determination of trace level microcystins in water using solid-phase extraction and high performance liquid chromatography
    Zhang, WH
    Xu, XQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (05) : 522 - 525
  • [3] Analysis of imazaquin in soybeans by solid-phase extraction and high-performance liquid chromatography
    Guo, C.
    Hu, J. -Y.
    Chen, X. -Y.
    Li, J. -Z.
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2008, 80 (02) : 173 - 177
  • [4] Analysis of Imazaquin in Soybeans by Solid-phase Extraction and High-performance Liquid Chromatography
    C. Guo
    J. -Y. Hu
    X. -Y. Chen
    J. -Z. Li
    Bulletin of Environmental Contamination and Toxicology, 2008, 80 : 173 - 177
  • [5] Multiresidue analysis of neonicotinoids by solid-phase extraction technique using high-performance liquid chromatography
    Chander Mohan
    Yogesh Kumar
    Jyotsana Madan
    Navneet Saxena
    Environmental Monitoring and Assessment, 2010, 165 : 573 - 576
  • [6] Multiresidue analysis of neonicotinoids by solid-phase extraction technique using high-performance liquid chromatography
    Mohan, Chander
    Kumar, Yogesh
    Madan, Jyotsana
    Saxena, Navneet
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 165 (1-4) : 573 - 576
  • [7] ANALYSIS OF MILRINONE IN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ODDIE, CJ
    JACKMAN, GP
    BOBIK, A
    JOURNAL OF CHROMATOGRAPHY, 1986, 374 (01): : 209 - 214
  • [8] ANALYSIS OF BASIC DRUGS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ONLINE SOLID-PHASE EXTRACTION AND AN UNMODIFIED SILICA COLUMN
    KELLY, MT
    SMYTH, MR
    DADGAR, D
    ANALYST, 1989, 114 (11) : 1377 - 1380
  • [9] Automated solid-phase extraction with high-performance liquid chromatography analysis of pyridinium crosslinks
    James, IT
    Walne, AJ
    Perrett, D
    ANALYTICAL BIOCHEMISTRY, 1996, 240 (01) : 29 - 36
  • [10] Quantitative analysis of free glycerol in biodiesel using solid-phase extraction and high-performance liquid chromatography
    Cozendey, Daniel de Almeida
    Muniz, Renan de Oliveira
    dos Santos, Rafael Cavalcante
    de Souza, Cristiane Gimenes
    de Andrade, Debora Franca
    D'Avila, Luiz Antonio
    MICROCHEMICAL JOURNAL, 2021, 168