Effect of finish line variants on marginal accuracy and fracture strength of ceramic optimized polymer/fiber-reinforced composite crowns

被引:49
|
作者
Cho, LR [1 ]
Choi, JM
Yi, YJ
Park, CJ
机构
[1] Kangnung Natl Univ, Dept Prosthodont, Kangnung, South Korea
[2] Kangnung Natl Univ, Coll Dent, Res Inst Oral Sci, Kangnung, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2004年 / 91卷 / 06期
关键词
D O I
10.1016/j.prosdent.2004.03.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Ceramic optimized polymer (Ceromer)/fiber-reinforced composite (FRC) crowns have been promoted as alternatives to conventional crowns. However, little is known regarding the ideal tooth preparation for this type of crown. Purpose. This in vitro study evaluated the marginal adaptation and fracture strength of ceromer/FRC crowns with respect to the various types of finish lines. Material and methods. Four metal dies with different finish lines (0.9-mm chamfer, 1.2-mm chamfer, 1.2-mm rounded shoulder, and 1.2-mm shoulder) were prepared. Forty (10 for each finish line) Targis/Vectris crowns were fabricated on duplicated base metal alloy dies. The restorations were stereoscopically evaluated at 56 points along the entire circumferential margin for measuring the margin adaptation before and after cementation with a resin luting agent. The specimens were then compressively loaded to failure using a universal testing machine. The marginal adaptation (mum) was analyzed with the Kruskal-Wallis test and post-hoc Dunnett test (alpha = .05). The fracture load (N) was analyzed with a 1-way analysis of the variance and the Scheffe adjustment (alpha = .05). The fractured surfaces of the crowns were examined with a scanning electron microscope to determine the mode of fracture. Results. The marginal adaptation of crowns with a shoulder finish line was significantly better than crowns with a chamfer finish line before and after cementation (P < .001). The increased marginal gap after cementation was the lowest in the 1.2-mm rounded shoulder group. The fracture strength of the crowns with the 0.9-mm chamfer and crowns with 1.2-mm chamfer was significantly greater than those of the crowns with the 1.2-mm shoulder or rounded shoulder (P = .011, P = .049, respectively). The mean fracture load of all crowns, regardless of the finish line design, was 1646 N. The fractured surface of the crown revealed adhesive failure and 3 types of cohesive failure (fracture of the Targis and Vectris, Targis fracture with a crack in the Vectris layer, and crushing without fracture). Conclusion. The marginal gaps were greater for the chamfer finish line specimens than in the shoulder finish line specimens. However, the fracture strength of the chamfer finish line specimens was greater than that of the shoulder finish line specimens.
引用
收藏
页码:554 / 560
页数:7
相关论文
共 50 条
  • [1] Marginal accuracy and fracture strength of ceromer/fiber-reinforced composite crowns: Effect of variations in preparation design
    Cho, LR
    Song, HY
    Koak, JY
    Heo, SJ
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (04): : 388 - 395
  • [2] Digital assessment of marginal accuracy in ceramic crowns fabricated with different marginal finish line configurations
    Faruqi, Saif
    Ganji, Kiran Kumar
    Bandela, Vinod
    Nagarajappa, Anil Kumar
    Mohamed, Roshan Noor
    Al Ahmed, Muhannad
    Farhan, Mohammed
    Alwakid, Waleed Naif
    Al-Hammad, Kholood A. S.
    Alam, Mohammad Khursheed
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 789 - 795
  • [3] Comparison of three types of fiber-reinforced composite molar crowns on their fracture resistance and marginal adaptation
    Behr, M
    Rosentritt, M
    Latzel, D
    Kreisler, T
    JOURNAL OF DENTISTRY, 2001, 29 (03) : 187 - 196
  • [4] The influence of different cements on the fracture resistance and marginal adaptation of all-ceramic and fiber-reinforced crowns
    Behr, M
    Rosentritt, M
    Mangelkramer, M
    Handel, G
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (05) : 538 - 542
  • [5] The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    Tao, Jianxiang
    Han, Dongwei
    QUINTESSENCE INTERNATIONAL, 2009, 40 (09): : 745 - 752
  • [6] Fracture resistance of fiber-reinforced vs. non-fiber-reinforced composite molar crowns
    M. Behr
    M. Rosentritt
    D. Latzel
    G. Handel
    Clinical Oral Investigations, 2003, 7 (3) : 135 - 139
  • [7] Fracture strength of posterior ceramic-composite FPD versus fiber-reinforced FPD.
    Rosentritt, M
    Behr, M
    Kolbeck, C
    Lang, R
    Handel, G
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1293 - 1293
  • [8] Relationship of Margin Design for Fiber-Reinforced Composite Crowns to Compressive Fracture Resistance
    Maghrabi, Abdulhamaid A.
    Ayad, Mohamed F.
    Garcia-Godoy, Franklin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (05): : 355 - 360
  • [9] Fracture resistance of short, randomly oriented, glass fiber-reinforced composite premolar crowns
    Garoushi, Sufyan
    Vallittu, Pekka K.
    Lassila, Lippo V. J.
    ACTA BIOMATERIALIA, 2007, 3 (05) : 779 - 784
  • [10] Effect of fiber position and orientation on fracture load of fiber-reinforced composite
    Dyer, SR
    Lassila, LVJ
    Jokinen, M
    Vallittu, PK
    DENTAL MATERIALS, 2004, 20 (10) : 947 - 955