Monte Carlo dose distributions for radiosurgery

被引:0
|
作者
Perucha, M [1 ]
Sánchez-Doblado, F [1 ]
Leal, A [1 ]
Rincón, M [1 ]
Núnez, L [1 ]
Arráns, R [1 ]
Carrasco, E [1 ]
Sánchez-Nieto, B [1 ]
Sánchez-Calzado, JA [1 ]
Errazquin, L [1 ]
机构
[1] Univ Seville, Fac Med, Dpto Fisiol Med & Biofis, E-41009 Seville, Spain
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The precision of Radiosurgery Treatment planning systems is limited by the approximations of their algorithms and by their dosimetrical input data. This fact is especially important in small fields. However, the Monte Carlo methods is an accurate alternative as it considers every aspect of particle transport. In this work an acoustic neurinoma is studied by comparing the dose distribution of both a planning system and Monte Carlo. Relative shifts have been measured and furthermore, Dose-Volume Histograms have been calculated for target and adjacent organs at risk.
引用
收藏
页码:561 / 564
页数:4
相关论文
共 50 条
  • [1] Denoising of Monte Carlo dose distributions
    Deasy, JO
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1494 - 1496
  • [2] Monte Carlo Simulation Dose Calculation for Intensity Modulated Radiosurgery
    Chan, K.
    Schneider, M.
    Smee, R.
    Heng, S.
    Baldock, C.
    RADIOSURGERY, VOL 7, 2010, 7 : 84 - 94
  • [3] Monte Carlo-calculated dose distributions for dynamic stereotactic radiosurgery with 1.5 and 3 mm photon beams
    Paskalev, K
    Seuntjens, J
    Patrocinio, H
    Podgorsak, E
    MEDICAL PHYSICS, 2002, 29 (06) : 1250 - 1250
  • [4] Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations
    Cheung, JYC
    Yu, KN
    Yu, CP
    Ho, RTK
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (03) : 461 - 465
  • [5] Denoising of Monte Carlo Dose Distributions Using UNet
    Javaid, U.
    Souris, K.
    Dasnoy, D.
    Montero, A. Barragan
    Huang, S.
    Lee, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E120 - E120
  • [6] Application of the peregrine Monte Carlo dose calculation system to stereotactic radiosurgery
    Siantar, CLH
    Cox, LJ
    vonWittenau, AS
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 182 - 182
  • [7] Density Effect on Monte Carlo Dose Calculation for Lung Robotic Radiosurgery
    Li, T.
    Zhang, Y.
    Ozhasoglu, C.
    Li, X.
    Heron, D. E.
    Huq, M. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S935 - S935
  • [8] DOSE DISTRIBUTIONS IN RADIOSURGERY
    PIKE, GB
    PODGORSAK, EB
    PETERS, TM
    PLA, C
    OLIVIER, A
    SOUHAMI, L
    MEDICAL PHYSICS, 1990, 17 (02) : 296 - 304
  • [9] Evaluation Of Clinical Dose Distributions Using Monte Carlo Methods
    Deloar, Hossain M.
    Griffin, Jonathan
    Bird, Mark
    Wilder, Ben
    Morgan, Steve
    Hsieh, Wen-long
    Sorell, Graham
    Knieda, Etsuo
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1956 - +
  • [10] Comparison of LDR to PDR dose distributions: A Monte Carlo study
    Price, M
    Gifford, K
    Horton, J
    Eifel, P
    Lawyer, A
    Jhingran, A
    Mourtada, F
    MEDICAL PHYSICS, 2005, 32 (06) : 2098 - 2098