Micromorphological effect of calcium phosphate coating on compatibility of magnesium alloy with osteoblast

被引:27
|
作者
Hiromoto, Sachiko [1 ]
Yamazaki, Tomohiko [2 ]
机构
[1] Natl Inst Mat Sci, Res Ctr Struct Mat, Corros Property Grp, Tsukuba, Ibaraki, Japan
[2] Natl Inst Mat Sci, Biosyst Control Grp, Funct Mat Res Ctr, Tsukuba, Ibaraki, Japan
基金
日本学术振兴会;
关键词
Magnesium; calcium phosphate coatings; topography; surface chemical property; cell adhesion; cell proliferation; biodegradable; CHEMICAL SOLUTION DEPOSITION; CORROSION BEHAVIOR; HYDROTHERMAL TREATMENT; OCTACALCIUM PHOSPHATE; IN-VITRO; SPECTROPHOTOMETRIC DETERMINATION; HYDROXYAPATITE CERAMICS; ORTHOPEDIC APPLICATIONS; PURE MAGNESIUM; HANKS SOLUTION;
D O I
10.1080/14686996.2016.1266238
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Octacalcium phosphate (OCP) and hydroxyapatite (HAp) coatings were developed to control the degradation speed and to improve the biocompatibility of biodegradable magnesium alloys. Osteoblast MG-63 was cultured directly on OCP-and HAp-coated Mg-3Al-1Zn (wt%, AZ31) alloy (OCP-and HAp-AZ31) to evaluate cell compatibility. Cell proliferation was remarkably improved with OCP and HAp coatings which reduced the corrosion and prevented the H2O2 generation on Mg alloy substrate. OCP-AZ31 showed sparse distribution of living cell colonies and dead cells. HAp-AZ31 showed dense and homogeneous distribution of living cells, with dead cells localized over and around corrosion pits, some of which were formed underneath the coating. These results demonstrated that cells were dead due to changes in the local environment, and it is necessary to evaluate the local biocompatibility of magnesium alloys. Cell density on HAp-AZ31 was higher than that on OCP-AZ31 although there was not a significant difference in the amount of Mg ions released in medium between OCP-and HAp-AZ31. The outer layer of OCP and HAp coatings consisted of plate-like crystal with a thickness of around 0.1 mu m and rod-like crystals with a diameter of around 0.1 mu m, respectively, which grew from a continuous inner layer. Osteoblasts formed focal contacts on the tips of plate-like OCP and rod-like HAp crystals, with heights of 2-5 mu m. The spacing between OCP tips of 0.8-1.1 mu m was wider than that between HAp tips of 0.2-0.3 mu m. These results demonstrated that cell proliferation depended on the micromorphology of the coatings which governed spacing of focal contacts. Consequently, HAp coating is suitable for improving cell compatibility and bone-forming ability of the Mg alloy.
引用
收藏
页码:96 / 109
页数:14
相关论文
共 50 条
  • [1] Calcium phosphate coating on magnesium alloy for modification of degradation behavior
    Cui F.-Z.
    Yang J.-X.
    Jiao Y.-P.
    Yin Q.-S.
    Zhang Y.
    Lee I.-S.
    Frontiers of Materials Science in China, 2008, 2 (2): : 143 - 148
  • [2] Enhancing the performance of calcium phosphate coating on a magnesium alloy for bioimplant applications
    Kannan, M. Bobby
    MATERIALS LETTERS, 2012, 76 : 109 - 112
  • [3] Preparation and corrosion behaviors of calcium phosphate conversion coating on magnesium alloy
    Su, Yingchao
    Guo, Yunting
    Huang, Zilong
    Zhang, Zhihui
    Li, Guangyu
    Lian, Jianshe
    Ren, Luquan
    SURFACE & COATINGS TECHNOLOGY, 2016, 307 : 99 - 108
  • [4] Modification of degradation behavior of magnesium alloy by IBAD coating of calcium phosphate
    Yang, J. X.
    Jiao, Y. P.
    Cui, F. Z.
    Lee, In-Seop
    Yin, Q. S.
    Zhang, Y.
    SURFACE & COATINGS TECHNOLOGY, 2008, 202 (22-23): : 5733 - 5736
  • [5] Effects of composition and hierarchical structures of calcium phosphate coating on the corrosion resistance and osteoblast compatibility of Mg alloys
    You, Mingyu
    Echeverry-Rendon, Monica
    Zhang, Lei
    Niu, Jialin
    Zhang, Jian
    Pei, Jia
    Yuan, Guangyin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 120
  • [6] Biomimetic coating of magnesium alloy for enhanced corrosion resistance and calcium phosphate deposition
    Cui, W.
    Beniash, E.
    Gawalt, E.
    Xu, Z.
    Sfeir, C.
    ACTA BIOMATERIALIA, 2013, 9 (10) : 8650 - 8659
  • [7] Composite Microstructure and Formation Mechanism of Calcium Phosphate Conversion Coating on Magnesium Alloy
    Su, Yingchao
    Su, Yichang
    Lu, Yanbo
    Lian, Jianshe
    Li, Guangyu
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (09) : G138 - G143
  • [8] Preparation and characterization of nanostructured dibasic calcium phosphate coating on magnesium alloy wire
    Liu, Guanxiong
    Wang, Jinyu
    Bian, Keke
    Zhu, Peizhi
    MATERIALS LETTERS, 2017, 209 : 323 - 326
  • [9] Calcium phosphate coating on biomedical WE43 magnesium alloy pretreated with a magnesium phosphate layer for corrosion protection
    Zhou, Haili
    Li, Jingyao
    Li, Jian
    Ruan, Qingdong
    Jin, Weihong
    Yu, Zhentao
    Li, Wei
    Chu, Paul K.
    SURFACE & COATINGS TECHNOLOGY, 2020, 401
  • [10] Effect of Strontium Pretreatment on Zinc Phosphate Coating Deposition on Magnesium Alloy
    Ismail, N. N.
    Zuhailawati, H.
    Abdalla, K.
    MATERIALS TODAY-PROCEEDINGS, 2019, 17 : 694 - 699