Intracranial Pressure Influences the Behavior of the Optic Nerve Head

被引:26
|
作者
Hua, Yi [1 ]
Tong, Junfei [1 ]
Ghate, Deepta [2 ,3 ]
Kedar, Sachin [2 ,4 ]
Gu, Linxia [1 ,3 ]
机构
[1] Univ Nebraska Lincoln, Dept Mech & Mat Engn, Lincoln, NE 68588 USA
[2] Univ Nebraska Med Ctr, Stanley Truhlsen Eye Inst, Omaha, NE 68105 USA
[3] Univ Nebraska Med Ctr, Ctr Adv Surg Technol, Omaha, NE 68198 USA
[4] Univ Nebraska Med Ctr, Dept Neurol Sci, Omaha, NE 68198 USA
关键词
intracranial pressure; optic nerve head; lamina cribrosa; postlaminar neural tissue; biomechanics; glaucoma; CEREBROSPINAL-FLUID PRESSURE; OPEN-ANGLE GLAUCOMA; TISSUE PRESSURE; RECONSTRUCTIONS; BIOMECHANICS; ARCHITECTURE; DEFORMATION; GRADIENT; STRAIN; SCLERA;
D O I
10.1115/1.4035406
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work, the biomechanical responses of the optic nerve head (ONH) to acute elevations in intracranial pressure (ICP) were systematically investigated through numerical modeling. An orthogonal experimental design was developed to quantify the influence of ten input factors that govern the anatomy and material properties of the ONH on the peak maximum principal strain (MPS) in the lamina cribrosa (LC) and postlaminar neural tissue (PLNT). Results showed that the sensitivity of ONH responses to various input factors was region-specific. In the LC, the peak MPS was most strongly dependent on the sclera thickness, LC modulus, and scleral canal size, whereas in the PLNT, the peak MPS was more sensitive to the scleral canal size, neural tissue modulus, and pia mater modulus. The enforcement of clinically relevant ICP in the retro-orbital subarachnoid space influenced the sensitivity analysis. It also induced much larger strains in the PLNT than in the LC. Moreover, acute elevation of ICP leads to dramatic strain distribution changes in the PLNT, but had minimal impact on the LC. This work could help to better understand patient-specific responses, to provide guidance on biomechanical factors resulting in optic nerve diseases, such as glaucoma, papilledema, and ischemic optic neuropathy, and to illuminate the possibilities for exploiting their potential to treat and prevent ONH diseases.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Optic nerve head geometry as a function of chronic intracranial pressure
    Moss, Heather
    Malhotra, Kiran
    Patel, Megh
    Shirazi, Zainab
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [2] Interplay between intraocular and intracranial pressure effects on the optic nerve head in vivo
    Zhu, Ziyi
    Waxman, Susannah
    Wang, Bo
    Wallace, Jacob
    Schmitt, Samantha E.
    Tyler-Kabara, Elizabeth
    Ishikawa, Hiroshi
    Schuman, Joel S.
    Smith, Matthew A.
    Wollstein, Gadi
    Sigal, Ian A.
    EXPERIMENTAL EYE RESEARCH, 2021, 213
  • [3] Interplay between intraocular and intracranial pressure effects on the optic nerve head in vivo
    Sigal, Ian A.
    Tran, Huong
    Zhu, Ziyi
    Wang, Bo
    Tyler-Kabara, Elizabeth
    Ishikawa, Hiroshi
    Schuman, Joel S.
    Smith, Matthew A.
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [4] The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
    Celik, Kaan
    Demiryurek, Bekir Enes
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2021, 79 (10) : 879 - 885
  • [5] Optical coherence tomography of the optic nerve head detects acute changes in intracranial pressure
    Anand, Aashish
    Pass, Anastas
    Urfy, Mian Z.
    Tang, Rosa
    Cajavilca, Christian
    Calvillo, Eusebia
    Suarez, Jose I.
    Rao, Chethan P. Venkatasubba
    Bershad, Eric M.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 29 : 73 - 76
  • [6] Head injury with unilateral optic nerve enlargement: Could it be caused by increased intracranial pressure?
    Tourtier, Jean-P.
    Lemoullec, Delphine
    Tazarourte, Karim
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2011, 18 (01) : 44 - 44
  • [7] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    PLOS ONE, 2020, 15 (02):
  • [8] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [9] Optic nerve changes in raised intracranial pressure
    Hansen, HC
    Helmke, K
    Kunze, K
    INTRACRANIAL AND INTRALABYRINTHINE FLUIDS: BASIC ASPECTS AND CLINICAL APPLICATIONS, 1996, : 227 - 232
  • [10] Finite Element Modeling of Factors Influencing Optic Nerve Head Deformation Due to Intracranial Pressure
    Feola, Andrew J.
    Myers, Jerry G.
    Raykin, Julia
    Mulugeta, Lealem
    Nelson, Emily S.
    Samuels, Brian C.
    Ethier, C. Ross
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (04) : 1901 - 1911