DOSE EQUIVALENT RATE CONSTANTS AND BARRIER TRANSMISSION DATA FOR NUCLEAR MEDICINE FACILITY DOSE CALCULATIONS AND SHIELDING DESIGN

被引:5
|
作者
Kusano, Maggie [1 ]
Caldwell, Curtis B. [2 ,3 ,4 ]
机构
[1] Sunnybrook Res Inst, Toronto, ON, Canada
[2] Sunnybrook Hlth Sci Ctr, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
[3] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
来源
HEALTH PHYSICS | 2014年 / 107卷 / 01期
关键词
nuclear medicine; radiation; medical; radionuclide; shielding; RAY BUILDUP FACTORS; MONTE-CARLO-SIMULATION; KERMA RATE CONSTANTS; ANNIHILATION RADIATION; GAMMA-RAYS; LEAD; BREMSSTRAHLUNG; RADIONUCLIDES; SPECTRA;
D O I
10.1097/HP.0000000000000051
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A primary goal of nuclear medicine facility design is to keep public and worker radiation doses As Low As Reasonably Achievable (ALARA). To estimate dose and shielding requirements, one needs to know both the dose equivalent rate constants for soft tissue and barrier transmission factors (TFs) for all radionuclides of interest. Dose equivalent rate constants are most commonly calculated using published air kerma or exposure rate constants, while transmission factors are most commonly calculated using published tenth-value layers (TVLs). Values can be calculated more accurately using the radionuclide's photon emission spectrum and the physical properties of lead, concrete, and/or tissue at these energies. These calculations may be non-trivial due to the polyenergetic nature of the radionuclides used in nuclear medicine. In this paper, the effects of dose equivalent rate constant and transmission factor on nuclear medicine dose and shielding calculations are investigated, and new values based on up-to-date nuclear data and thresholds specific to nuclear medicine are proposed. To facilitate practical use, transmission curves were fitted to the three-parameter Archer equation. Finally, the results of this work were applied to the design of a sample nuclear medicine facility and compared to doses calculated using common methods to investigate the effects of these values on dose estimates and shielding decisions. Dose equivalent rate constants generally agreed well with those derived from the literature with the exception of those from NCRP 124. Depending on the situation, Archer fit TFs could be significantly more accurate than TVL-based TFs. These results were reflected in the sample shielding problem, with unshielded dose estimates agreeing well, with the exception of those based on NCRP 124, and Archer fit TFs providing a more accurate alternative to TVL TFs and a simpler alternative to full spectral-based calculations. The data provided by this paper should assist in improving the accuracy and tractability of dose and shielding calculations for nuclear medicine facility design.
引用
收藏
页码:60 / 72
页数:13
相关论文
共 50 条
  • [1] Shielding and Facility Design in Nuclear Medicine
    Padovani, Renato
    RADIATION PROTECTION IN MEDICAL PHYSICS, 2009, : 123 - 131
  • [2] Effective dose and effective dose equivalent in nuclear medicine
    Toohey, RE
    Stabin, MG
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C473 - C475
  • [3] Effective dose equivalent in nuclear medicine investigations
    Johansson, L.
    Mattsson, S.
    Nosslin, B.
    Proceedings of the International Congress of Radiation Research, 1984, : 2 - 21
  • [4] Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine
    Szermerski, Bastian
    Bruchmann, Iris
    Behrens, Rolf
    Geworski, Lilli
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (04): : 304 - 310
  • [5] Dose and dose rate measurements for radiation exposure scenarios in nuclear medicine
    Sudbrock, Ferdinand
    Uhrhan, Klara
    Rimpler, Arndt
    Schicha, Harald
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1303 - 1306
  • [6] Nuclear medicine dosimetry: Quantitative imaging and dose calculations
    Glatting, Gerhard
    Lassmann, Michael
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (04): : 246 - 247
  • [7] Occupational Radiation Exposure in the Department of Nuclear Medicine - the Effect of Distance and Shielding Material on the Dose Rate
    Saila, T.
    Hakkarainen, S.
    Hirsimaki, K.
    Taatila, T.
    Vilpas, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S225 - S226
  • [8] Dose equivalent transmission data for shielding industrial x-ray facilities up to 800 kV
    Bourgois, L.
    Menard, S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 471 - 479
  • [9] APPLICATION OF THE EFFECTIVE DOSE EQUIVALENT TO NUCLEAR-MEDICINE PATIENTS
    POSTON, JW
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (04) : 714 - 716
  • [10] The equivalent dose for different part of hand for nuclear medicine workers
    Jankowski, J.
    Olszewski, J.
    Wrzesien, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2099 - +