Reliability and Validity of the Functional Gait Assessment (German Version) in Subacute Stroke Patients

被引:53
|
作者
Thieme, Holm [1 ]
Ritschel, Claudia [2 ]
Zange, Christian [2 ]
机构
[1] Klin Bavaria Kreischa, Sch Physiotherapy Occupat Therapy & Speech & Lang, Sachsen, Germany
[2] Klin Bavaria Kreischa, Dept Neurol Rehabil, Sachsen, Germany
来源
关键词
Balance; Gait; Outcome assessment; Rehabilitation; Reliability and validity; Stroke; MINI-MENTAL-STATE; PSYCHOMETRIC PROPERTIES; VESTIBULAR DYSFUNCTION; BARTHEL INDEX; BALANCE SCALE; HEALTH; REHABILITATION; RESPONSIVENESS; INDIVIDUALS; PERFORMANCE;
D O I
10.1016/j.apmr.2009.03.007
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate validity and reliability of the Functional Gait Assessment (FGA) (German version) as a measure for balance abilities during walking in subacute stroke patients. Design: Cohort study. Setting: Inpatient rehabilitation center. Participants: Ambulatory subjects (N=28) at a maximum of 6 months after stroke participated in this study. One direct observer and 2 video observers rated the FGA. Interventions: Not applicable. Main Outcome Measures: Performance of the FGA was video recorded and directly rated. For testing concurrent validity of the FGA, subjects also completed testing in the Berg Balance Scale, fast walking speed, the Functional Ambulatory Category, the Rivermead Mobility Index, and the Barthel Index. Intrarater reliability, interrater reliability, and concurrent validity of the FGA were analyzed. Results: Intrarater (intraclass correlation coefficient=.97) and interrater reliability (intraclass correlation coefficient =.94) were almost perfect for total scores. Reliability of single items varied between substantial and almost perfect values. Analysis revealed significant correlations between the FGA and other measures of gait and balance functions between Spearman rho values of .71 and .93. The FGA differs significantly between levels of gait ability (Functional Ambulatory Category) (P <=.01). Conclusions: Almost perfect intrarater and interrater reliability for total FGA scores and good concurrent validity were shown in this study. Therefore, the FGA (German version) can be used as a reliable and valid tool to assess functional gait performance of patients in subacute stages after stroke.
引用
收藏
页码:1565 / 1570
页数:6
相关论文
共 50 条
  • [1] Reliability and validity of the Cognitive Assessment for Stroke Patients (Chinese version) for patients with nonaphasic stroke
    Xiang, Li-Sha
    Zhang, Yi
    Xie, Fan
    Fei, Xiao
    Wang, Ya
    Shi, Yue
    APPLIED NEUROPSYCHOLOGY-ADULT, 2023,
  • [2] Validity and Reliability of the Thai Version of the Gait Assessment and Intervention Tool (GAIT)
    Saengsuwan, Jittima
    Sirasaporn, Patpiya
    STROKE RESEARCH AND TREATMENT, 2020, 2020
  • [3] Validity and Reliability of the Japanese Version of the Frontal Assessment Battery in Patients with Stroke
    Sakai, Katsuya
    Hosoi, Yuichiro
    Harada, Yusuke
    Morikawa, Kenji
    Kato, Yuichi
    NEUROLOGY INTERNATIONAL, 2024, 16 (05): : 1086 - 1093
  • [4] Reliability and validity of the Brief Assessment of Impaired Cognition (Chinese version) for stroke patients
    Yuan, Xiao-Fang
    Zhang, Yi
    Zhang, Yu
    Wu, Ye-Huan
    Shi, Yue
    Cheng, Yun
    Xie, Fan
    APPLIED NEUROPSYCHOLOGY-ADULT, 2023, 30 (01) : 27 - 33
  • [5] Reliability and Validity of the Functional Gait Assessment: A Systematic Review
    Weber, Colleen
    Schwieterman, Megan
    Fier, Kayla
    Berni, John
    Swartz, Natalie
    Phillips, Robert S.
    Reneker, Jennifer C.
    PHYSICAL & OCCUPATIONAL THERAPY IN GERIATRICS, 2016, 34 (01) : 88 - 103
  • [6] A Chinese version of the Stroke Illness Perception Questionnaire-Revised: Reliability and validity assessment in stroke patients
    Lei, Xiaoyu
    Liu, Yanjin
    Guo, Yuanli
    Guo, Lina
    Dong, Xiaofang
    Wei, Miao
    He, Yu
    INTERNATIONAL JOURNAL OF NURSING PRACTICE, 2024, 30 (06)
  • [7] Validity and reproducibility of the Functional Gait Assessment in persons after stroke
    Van Bloemendaal, Maijke
    Bout, Walter
    Bus, Sicco A.
    Nollet, Frans
    Geurts, Alexander C. H.
    Beelen, Anita
    CLINICAL REHABILITATION, 2019, 33 (01) : 94 - 103
  • [8] Functional Gait Assessment - German Version Translation of an Instrument for the Assessment of Balance Ability during Gait
    Thieme, H.
    Ritschel, C.
    Zange, C.
    PHYSIOSCIENCE, 2009, 5 (01) : 5 - 11
  • [9] Development of the Japanese version of the stroke stigma scale: a validity and reliability assessment
    Kitamura, Shin
    Miyamoto, Reiko
    Watanabe, Shota
    Yoshida, Taiki
    Ishii, Yoshikazu
    TOPICS IN STROKE REHABILITATION, 2024, 31 (07) : 745 - 754
  • [10] The Turkish version of the cognitive assessment scale for stroke patients (CASP-TR): a reliability and validity
    Oge-Dasdogen, Ozlem
    Bengisu, Serkan
    Yildiz, Hatice Yelda
    Krespi, Yakup
    APHASIOLOGY, 2024,