Computed tomography and low-field magnetic resonance imaging of the pituitary gland in dogs with pituitary-dependent hyperadrenocorticism: 11 cases (2001-2003)

被引:19
|
作者
Auriemma, Edoardo [1 ]
Barthez, Paul Y. [2 ]
van der Vlugt-Meijer, Roselinda H. [2 ]
Voorhout, George [2 ]
Meij, Bjoern P. [2 ]
机构
[1] Univ Utrecht, Fac Vet Med, Div Diagnost Imaging, NL-3508 TC Utrecht, Netherlands
[2] Univ Utrecht, Fac Vet Med, Dept Clin Sci Compan Anim, NL-3508 TC Utrecht, Netherlands
关键词
TRANSSPHENOIDAL HYPOPHYSECTOMY; HEALTHY DOGS; MR-IMAGES; CANINE HYPERADRENOCORTICISM; POSTERIOR LOBE; DIAGNOSIS; SIGNAL; FREQUENCY; GRADIENT; BRAIN;
D O I
10.2460/javma.235.4.409
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To compare the results of computed tomography (CT) and magnetic resonance imaging (MRI) of the pituitary gland in dogs with pituitary-dependent hyperadrenocorticism (PDH) caused by histologically confirmed pituitary adenoma. Design-Retrospective case series. Animals-11 dogs with PDH that underwent transsphenoidal hypophysectomy. Procedures-Medical records of dogs examined between January 2001 and March 2003 were reviewed. Dogs were included in this study if they had clinical signs of hypercortisolism at the time of admission (for which PDH was diagnosed) and underwent transsphenoidal hypophysectomy. Pre- and postcontrast CT and low-field MRI (0.2-Tesla magnet) were performed on the same day as surgery for each dog. Results-An abnormal pituitary gland was found in 7 dogs by use of MRI and in the same 7 dogs by use of CT Significant differences were found between postcontrast CT and MR images for height, width, and length of the pituitary gland; brain area; and thickness of the sphenoid bone. However, the pituitary gland height-to-brain area ratio determined from postcontrast CT and MR images was not significantly different. The signal-to-noise ratio and contrast-to-noise ratio of pre- and postcontrast MR images were significantly higher than those of the CT images. Conclusions and Clinical Relevance-Low-field MRI and dynamic CT imaging of the pituitary gland provided comparable information on the presence of pituitary adenomas in dogs with PDH. (J Am Vet Med Assoc 2009;235:409-414)
引用
收藏
页码:409 / 414
页数:6
相关论文
共 29 条
  • [1] Dynamic computed tomography of the pituitary gland in dogs with pituitary-dependent hyperadrenocorticism
    van der Vlugt-Meijer, RH
    Meij, BP
    van den Ingh, TSGAM
    Rijnberk, A
    Voorhout, G
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2003, 17 (06) : 773 - 780
  • [2] Imaging of the pituitary gland in dogs with pituitary-dependent hyperadrenocorticism
    van der Vlugt-Meijer, RH
    Voorhout, G
    Meij, BP
    MOLECULAR AND CELLULAR ENDOCRINOLOGY, 2002, 197 (1-2) : 81 - 87
  • [3] Magnetic Resonance Imaging Assessment of Pituitary Posterior Lobe Displacement in Dogs with Pituitary-Dependent Hyperadrenocorticism
    Taoda, Takahiro
    Hara, Yasushi
    Masuda, Hiroyuki
    Teshima, Takahiro
    Nezu, Yoshinori
    Teramoto, Akira
    Orima, Hiromitsu
    Okano, Shozo
    Tagawa, Masahiro
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2011, 73 (06): : 725 - 731
  • [4] MAGNETIC-RESONANCE-IMAGING OF THE BRAIN IN DOGS WITH RECENTLY DIAGNOSED BUT UNTREATED PITUITARY-DEPENDENT HYPERADRENOCORTICISM
    BERTOY, EH
    FELDMAN, EC
    NELSON, RW
    DUESBERG, CA
    KASS, PH
    REID, MH
    DUBLIN, AB
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1995, 206 (05) : 651 - 656
  • [5] Dynamic computed tomography of the pituitary gland using a single slice scanner in dogs with pituitary-dependent hypercortisolism
    Del Magno, Sara
    Grinwis, Guy C. M.
    Voorhout, George
    Meij, Bjorn P.
    RESEARCH IN VETERINARY SCIENCE, 2016, 107 : 42 - 49
  • [6] One-year follow-up evaluation of magnetic resonance imaging of the brain in dogs with pituitary-dependent hyperadrenocorticism
    Bertoy, EH
    Feldman, EC
    Nelson, RW
    Dublin, AB
    Reid, MH
    Feldman, MS
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1996, 208 (08) : 1268 - &
  • [7] Low-Field Magnetic Resonance Imaging and Multislice Computed Tomography for the Detection of Cervical Syringomyelia in Dogs
    Kromhout, K.
    van Bree, H.
    Broeckx, B. J. G.
    Bhatti, S.
    De Decker, S.
    Polis, I.
    Gielen, I.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2015, 29 (05) : 1354 - 1359
  • [8] APPLICATION OF LOW-FIELD INTRAOPERATIVE MAGNETIC RESONANCE IMAGING IN TRANSSPHENOIDAL SURGERY FOR PITUITARY ADENOMAS
    Kim, Eui Hyun
    Kim, Sun Ho
    NEURO-ONCOLOGY, 2012, 14 : 121 - 121
  • [9] Surgical Treatment of Pituitary Adenomas Using Low-Field Intraoperative Magnetic Resonance Imaging
    Tabakow, Pawel
    Czyz, Marcin
    Jarmundowicz, Wlodzimierz
    Lechowicz-Glogowska, Ewa
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2012, 21 (04): : 495 - 503
  • [10] COMPARATIVE MORPHOLOGICAL-STUDY OF THE PITUITARY-GLAND BY COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE IMAGING
    LOXTON, AJ
    SOUTH AFRICAN MEDICAL JOURNAL, 1988, 74 (08): : 406 - 407