Optimization of confocal laser induced fluorescence in a plasma

被引:4
|
作者
VanDervort, R. [1 ]
Elliott, D. [1 ]
McCarren, D. [1 ]
McKee, J. [1 ]
Soderholm, M. [1 ]
Sears, S. [1 ]
Scime, E. [1 ]
机构
[1] W Virginia Univ, Dept Phys, Morgantown, WV 26506 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 11期
关键词
TUNABLE DIODE-LASER; HELICON PLASMA; FIELD;
D O I
10.1063/1.4886424
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Laser Induced Fluorescence (LIF) provides measurements of flow speed, temperature, and density of ions or neutrals in a plasma. Traditionally, a LIF measurement requires two ports on a plasma device; one for laser injection and one for emission collection. Proper alignment of LIF optics is time consuming and sensitive to mechanical vibration. We describe a confocal configuration for LIF that requires a single port and requires no alignment. The measurement location is scanned radially by physically moving the entire optical structure. Confocal LIF measurements are compared to traditional LIF measurements over the same radial range. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] A confocal laser-induced fluorescence diagnostic with an annular laser beam
    Romadanov, I.
    Raitses, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (07):
  • [2] Demonstration of confocal laser induced fluorescence at long focal lengths
    Henriquez, Miguel F.
    Thompson, Derek S.
    Jemiolo, Andrew J.
    Scime, Earl E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [3] Auto Focusing Confocal Laser Induced Fluorescence Detection System
    Wang, Xuefei
    Yan, Weiping
    Bai, Haiming
    Li, Wei
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 : 364 - 368
  • [4] Laser-induced fluorescence detection of lead atoms in a laser-induced plasma: An experimental analytical optimization study
    Laville, Stephane
    Goueguel, Christian
    Loudyi, Hakim
    Vidal, Francois
    Chaker, Mohamed
    Sabsabi, Mohamad
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (04) : 347 - 353
  • [5] Confocal laser induced fluorescence with comparable spatial localization to the conventional method
    Thompson, Derek S.
    Henriquez, Miguel F.
    Scime, Earl E.
    Good, Timothy N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10):
  • [6] Laser induced fluorescence in a pulsed argon plasma
    Scime, E
    Biloiu, C
    Compton, C
    Doss, F
    Venture, D
    Heard, J
    Choueiri, E
    Spektor, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02): : 026107 - 1
  • [7] LASER-INDUCED FLUORESCENCE AS A PLASMA DIAGNOSTIC
    KOHLER, P
    STERN, RA
    HELVETICA PHYSICA ACTA, 1983, 56 (04): : 934 - 934
  • [8] Laser induced fluorescence of argon ions in a plasma presheath
    Oksuz, L
    Khedr, MA
    Hershkowitz, N
    PHYSICS OF PLASMAS, 2001, 8 (05) : 1729 - 1733
  • [9] Laser-induced fluorescence for ITER divertor plasma
    Gorbunov, A. V.
    Mukhin, E. E.
    Berik, E. B.
    Vukolov, K. Yu.
    Lisitsa, V. S.
    Kukushkin, A. S.
    Levashova, M. G.
    Barnsley, R.
    Vayakis, G.
    Walsh, M. J.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 695 - 698
  • [10] LASER-INDUCED FLUORESCENCE MEASUREMENTS IN THE PISCES PLASMA
    RETTIG, CL
    PEEBLES, WA
    LUHMANN, NC
    GOHIL, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1536 - 1536