Sonographic Measurement of Cross-Sectional Area of the Median Nerve in the Diagnosis of Carpal Tunnel Syndrome: Correlation with Nerve Conduction Studies

被引:115
|
作者
Moran, Luz [1 ]
Perez, Maria [1 ]
Esteban, Angel [2 ]
Bellon, Jose [3 ]
Arranz, Beatriz [2 ]
del Cerro, Miguel [4 ]
机构
[1] Hosp Univ Gregorio Maranon, Dept Radiol, Madrid, Spain
[2] Hosp Gregorio Maranon, Dept Neurophysiol, Madrid, Spain
[3] Hosp Gregorio Maranon, Dept Stat, Madrid, Spain
[4] Hosp Gregorio Maranon, Dept Traumatol, Madrid, Spain
关键词
carpal tunnel syndrome; sonography; nerve conduction studies; HIGH-RESOLUTION SONOGRAPHY; ELECTROMYOGRAPHY; ULTRASOUND;
D O I
10.1002/jcu.20551
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To assess the usefulness of sonographic measurement of the median nerve cross-sectional area (CSA) in the diagnosis of carpal tunnel syndrome (CTS) and grading of its severity using nerve conduction (NC) studies as the standard. Method. The CSA of the median nerve was measured at the tunnel inlet and outlet using the ellipse formula and automatic tracing in 72 hands with suspicion of CTS. Result. The lack of inter-reader reliability led to excluding CSA measurements obtained at the tunnel outlet. Based on the receiver operating characteristic curves, the following cut-off points for the CSA of the median nerve at the tunnel inlet was selected: 9.8 mm and 12.3 mm(2) for the ellipse formula and 11 and 13 mm 2 for automatic tracing.For the ellipse formula, a CSA less than or equal to 9.8 mm(2) excluded CTS whereas a CSA greater than or equal to 12.3 mm(2) was diagnostic of CTS with measurements between 9.8 and 12.3 mm(2) being indeterminate and requiring NC studies. For automatic tracing, the cutoff value of 11 mm 2 was excluded because of the high percentage of false negatives, whereas CSAs greater than or equal to 13 mm(2) were diagnostic of CTS. There were no statistically significant differences in CSA measurements between the various degrees of CTS severity determined by NC studies. Conclusion. Sonographic measurement of median nerve CSA at the tunnel inlet is a good alternative to NC studies as the initial diagnostic test for CTS, but it cannot grade the severity of CTS as well as NC studies. (C) 2009 Wiley Periodicals, Inc. J Clin Ultrasound 37:125-131, 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/jcu.20551
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [1] Sonographic Measurement of Cross-Sectional Area of the Median Nerve in the Diagnosis of Carpal Tunnel Syndrome: Correlation With Nerve Conduction Studies
    Pazzaglia, C.
    Padua, L.
    JOURNAL OF CLINICAL ULTRASOUND, 2010, 38 (03) : 145 - 146
  • [2] Sonographic Measurement of Median Nerve Cross-Sectional Area to Determine Severity of Carpal Tunnel Syndrome: A Cautionary Tale
    Savage, Nathan J.
    McKell, John S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (09) : 1645 - 1659
  • [3] Sonographic Measurement of Cross-sectional Area of the Median Nerve in Academic Dentists Without Symptoms or Signs of Carpal Tunnel Syndrome
    Asbeutah, Akram
    Dashti, Mohsen
    AlMajran, Abdullah
    Ghayyath, Aref
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2019, 35 (02) : 105 - 111
  • [4] Diagnostic utility of the sonographic median to ulnar nerve cross-sectional area ratio in carpal tunnel syndrome
    Atan, Tugba
    Gunendi, Zafer
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (01) : 110 - 116
  • [5] Bifid Median Nerve in Carpal Tunnel Syndrome: Assessment with US Cross-sectional Area Measurement
    Klauser, Andrea S.
    Halpern, Ethan J.
    Faschingbauer, Ralph
    Guerra, Florian
    Martinoli, Carlo
    Gabl, Markus F.
    Arora, Rohit
    Bauer, Thomas
    Sojer, Martin
    Loescher, Wolfgang N.
    Jaschke, Werner R.
    RADIOLOGY, 2011, 259 (03) : 808 - 815
  • [6] Median Nerve Cross-Sectional Area and Carpal Tunnel Syndrome in Specific Populations
    Savage, Nathan J.
    Mckell, John S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (09) : 1683 - 1694
  • [7] Value of cross-sectional area of median nerve by MRI in carpal tunnel syndrome
    Park, Jin Sung
    Won, Hee-Chan
    Oh, Jin-Young
    Kim, Dong-Hee
    Hwang, Sun-Chul
    Yoo, Jun-Il
    ASIAN JOURNAL OF SURGERY, 2020, 43 (06) : 654 - 659
  • [8] Comparison of High Resolution Ultrasonography and Nerve Conduction Study in the Diagnosis of Carpal Tunnel Syndrome: Diagnostic Value of Median Nerve Cross-Sectional Area
    Mohammadi, A.
    Afshar, A. R.
    Masudi, S.
    Etemadi, A.
    IRANIAN JOURNAL OF RADIOLOGY, 2009, 6 (03) : 147 - 152
  • [10] A PROSPECTIVE STUDY EXAMINING THE SENSITIVITY OF ULTRASOUND DETERMINED MEDIAN NERVE CROSS-SECTIONAL AREA WITH NERVE CONDUCTION INVESTIGATION IN THE DIAGNOSIS OF CARPAL TUNNEL SYNDROME
    Hameed, Beena
    Khanbhai, Tamim
    Resteghini, Peter
    Bourke, Stephen
    RHEUMATOLOGY, 2015, 54 : 151 - 151