Condition monitoring of composite insulators using partial discharge analysis

被引:0
|
作者
Giriantari, I. A. D. [1 ]
机构
[1] Udayana Univ, Dept Elect Engn, Bali, Indonesia
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Composite insulator are widely used as an outdoor insulator now days. Deterioation due to severe weather and vandalism are usually undetactable. There are many techniques have been introduced in order to detect the insulator condition, one of the technique is introduce here by using Partial Discharge analysis. The work has been done by examining the PD patterns and behaviour of three different insulator materials that are subjected to high humidity and pollution in the small chamber. This work has exhibited a condition monitoring of composite insulator using PD analysis. It showed an assosiation between the PDs pattern and behaviour and the insulator condition. In addition the method used has gave an oppurtunity to do on-line monitoring.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 50 条
  • [1] Line Composite Insulators Condition Monitoring through Partial Discharge Measurement
    Abedini-Livari, Ali
    Eshaghi-Maskouni, Mandi
    Vakilian, Mehdi
    Firuzi, Keyvan
    34TH INTERNATIONAL POWER SYSTEM CONFERENCE (PSC2019), 2019, : 595 - 600
  • [2] New Condition Monitoring Techniques for Composite Insulators
    J Electr Electron Eng Aust, 2 (91-98):
  • [3] Log Periodic Antenna Based Partial Discharge Detector for Condition Monitoring of High Voltage Insulators
    De Zoysa, H. R. T.
    Madushani, M. G. D.
    Siriwardhana, G. D. K.
    Wijethunge, K. U. N. S. S.
    Lucas, J. R.
    Samarasinghe, R.
    2018 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON) 4TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2018, : 477 - 481
  • [4] Partial Discharge On-Line Monitoring of Outdoor Insulators
    Shurrab, Ibrahim Y.
    El-Hag, Ayman
    Assaleh, Khaled
    Ghunem, Refat
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 391 - 394
  • [5] Online Oil Condition Monitoring Using a Partial- Discharge Signal
    El-Hag, Ayman H.
    Saker, Yasser Adel
    Shurrab, Ibrahim Yehia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 1288 - 1289
  • [6] Interfacial aging in composite insulators as a result of partial discharge activity
    Bastidas, Pablo D.
    Rowland, Simon M.
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 13 - 16
  • [7] Visual Live-Line Condition Monitoring of Composite Insulators
    Veerappan, Chithambaram A.
    Green, Peter R.
    Rowland, Simon M.
    2010 1ST INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY, 2010,
  • [8] Condition monitoring of dielectric behaviour leading to the diagnosis of partial discharge onset using neural network analysis
    Bish, N.B.
    Howson, P.A.
    Howlett, R.J.
    Proceedings of the Universities Power Engineering Conference, 1999, 1 : 303 - 306
  • [9] Experience of GIS condition diagnosis using partial discharge monitoring by UHF method
    Ono, Masatomo
    Matsuyama, Yoshimune
    Otaka, Nobuko
    Yamagiwa, Tokio
    Kato, Tatsuro
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1108 - +
  • [10] An overview of state-of-the-art partial discharge analysis techniques for condition monitoring
    Data Analytics Department, Institute for Infocomm Research, ASTAR, 1 Fusionopolis Way #21-01 Connexis, Singapore
    138632, Singapore
    IEEE Electr Insul Mag, 6 (22-35):