Experimental factors effecting stability of Electrochemical Impedance Spectroscopy Measurements

被引:0
|
作者
Koo, Beomseo [1 ]
Weiland, James [1 ]
机构
[1] Univ Michigan, Biomed Engn Dept, Ann Arbor, MI 48105 USA
基金
美国国家科学基金会;
关键词
ELECTRICAL-STIMULATION; TISSUE; NUCLEUS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Impedance measurement using Electrochemical Impedance Spectroscopy is a widely utilized technique in neural electrodes. Research and clinical devices that incorporate stimulating and recording microelectrodes routinely characterize the material's integrity and its functionality through impedance measurement. Nominal impedance values ensure a stable neural electrode-tissue contact capable of passing through power efficient electric signals with desired signal-to-noise ratio or effective volume coverage. However, the complexity of the in vivo environment limits the usage of the three-electrode setup, which has been accepted as the ideal method in providing a stable impedance measurement. Impedance data measured from microelectrodes in three-electrode and two-electrode setups show that the two setups have similar outcomes in terms of the impedance modulus over a 0.5 Hz-100 kHz frequency range. Usage of a platinum counter electrode lowered the overall variance in impedance readings compared to the stainless steel counter electrode. However, correlation coefficient values (>0.97) between three-electrode and two-electrode setups show that impedance values seldom deviate due to changes in electrode setup. Based on the results of this study, the usage of the two-electrode setup in vivo allowed acceptable electrochemical impedance spectroscopy accuracy, and the utilization of a platinum counter electrode is recommended to reduce measurement variance.
引用
收藏
页码:2949 / 2952
页数:4
相关论文
共 50 条
  • [1] Electrochemical impedance spectroscopy for better electrochemical measurements
    Park, SM
    Yoo, JS
    ANALYTICAL CHEMISTRY, 2003, 75 (21) : 455A - 461A
  • [2] An experimental study of the robustness of electrochemical impedance spectroscopy measurements within consecutive cycles
    Zhang, Wenlin
    Ahmed, Ryan
    Habibi, Saeid
    2024 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ITEC 2024, 2024,
  • [3] Model study investigating the role of interfacial factors in electrochemical impedance spectroscopy measurements
    Chen, M
    Yu, QS
    Reddy, CM
    Yasuda, HK
    CORROSION, 2000, 56 (07) : 709 - 721
  • [4] Rapid Analytical Instrumentation for Electrochemical Impedance Spectroscopy Measurements
    Hu, Yuan
    Brahim, Sean
    Maat, Stefan
    Davies, Patricia
    Kundu, Arpan
    Fisher, Timothy S.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [5] On the use of drift correction for electrochemical impedance spectroscopy measurements
    Orazem, Mark E.
    Ulgut, Burak
    ELECTROCHIMICA ACTA, 2023, 443
  • [6] CORROSION RATE MEASUREMENTS BY NONLINEAR ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY
    DAROWICKI, K
    CORROSION SCIENCE, 1995, 37 (06) : 913 - 925
  • [7] Stability study and categorization of electrochemical oscillators by impedance spectroscopy
    Koper, MTM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 409 (1-2) : 175 - 182
  • [8] Stability study and categorization of electrochemical oscillators by impedance spectroscopy
    Univ of Utrecht, Utrecht, Netherlands
    J Electroanal Chem, 1-2 (175-182):
  • [9] Improved experimental setup to reach a broad frequency domain in local electrochemical impedance spectroscopy measurements
    Gomes, Maurilio Pereira
    Gateman, Samantha Michelle
    Costa, Isolda
    Gharbi, Oumaima
    Ngo, Kieu
    Rossi, Jesualdo Luiz
    Turmine, Mireille
    Vivier, Vincent
    MEASUREMENT, 2022, 200
  • [10] VALIDATION OF EXPERIMENTAL-DATA IN ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY
    POPKIROV, GS
    SCHINDLER, RN
    ELECTROCHIMICA ACTA, 1993, 38 (07) : 861 - 867