Evaluating the upper arm and the abdomen sites for the continuous monitoring of interstitial fluid glucose concentration

被引:0
|
作者
McGarraugh, GV
Sharp, CA
机构
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:A462 / A463
页数:2
相关论文
共 50 条
  • [1] Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites
    Steineck, Isabelle Isa Kristin
    Mahmoudi, Zeinab
    Ranjan, Ajenthen
    Schmidt, Signe
    Jorgensen, John Bagterp
    Norgaard, Kirsten
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (05) : 295 - 302
  • [2] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728
  • [3] ACCURACY AND PRECISION EVALUATION OF FLASH GLUCOSE MONITORING SENSORS IN DIFFERENT SITES: THE ABDOMEN AND UPPER THIGH COMPARED TO THE UPPER ARM (OUT OF SIGHT)
    Charleer, S.
    Mathieu, C.
    Nobels, F.
    Gillard, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A23 - A24
  • [4] Continuous Glucose Monitoring by Real Time Sensor in Interstitial Fluid
    Honsova, Sarka
    Navratil, Tomas
    XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 63 - 67
  • [5] A method for continuous glucose monitoring in interstitial fluid based on microdialysis
    Li, D. (dchli@tju.edu.cn), 1600, Tianjin University (46):
  • [6] An Interstitial Fluid Transdermal Extraction System for Continuous Glucose Monitoring
    Yu, Haixia
    Li, Dachao
    Roberts, Robert C.
    Xu, Kexin
    Tien, Norman C.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (04) : 917 - 925
  • [7] Validation of interstitial fluid continuous glucose monitoring in cystic fibrosis
    Dobson, L
    Sheldon, CD
    Hattersley, AT
    DIABETES CARE, 2003, 26 (06) : 1940 - 1941
  • [8] Accuracy and precision of flash glucose monitoring sensors inserted into the abdomen and upper thigh compared with the upper arm
    Charleer, Sara
    Mathieu, Chantal
    Nobels, Frank
    Gillard, Pieter
    DIABETES OBESITY & METABOLISM, 2018, 20 (06): : 1503 - 1507
  • [9] Measurement of glucose concentration in interstitial fluid - an alternative or a supplement to conventional blood glucose monitoring?
    Kublin, Oskar
    Stepien, Mariusz
    CLINICAL DIABETOLOGY, 2019, 8 (02): : 121 - 126
  • [10] Comparison of Dexcom G6 Continuous Glucose Monitoring Performance between Abdomen and Upper Arm Placement in Hospitalized Patients with Diabetes
    Migdal, Alexandra
    Zamudio, Karla W.
    Perez-Guzman, Mireya C.
    Idrees, Thaer
    Albury, Bonnie S.
    Davis, Georgia
    Urrutia, Maria A.
    Galindo, Rodolfo J.
    Vellanki, Priyathama
    Fayfman, Maya
    Cardona, Saumeth
    Castro-Revoredo, Iris A.
    Pasquel, Francisco J.
    Peng, Limin
    Umpierrez, Guillermo E.
    DIABETES, 2021, 70