Design methodology of a non-invasive sensor to measure the current of the output capacitor for a very fast non-linear control

被引:26
|
作者
Huerta, Santa C. [1 ]
Alou, P. [1 ]
Oliver, J. A. [1 ]
Garcia, O. [1 ]
Cobos, J. A. [1 ]
Abou-Alfotouh, A.
机构
[1] Univ Politecn Madrid, Ctr Elect Ind, Madrid, Spain
关键词
D O I
10.1109/APEC.2009.4802754
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The combination of non-linear control and linear control proposed in [1] has a very fast transient response (voltage step from I V to 1.5 V in 2 Its). In order to achieve this fast transient response the non-linear scheme is based on measuring the current of the output capacitor of a Buck converter. The design of this current sensor is complex due to parasitic effects such as component tolerances (bandwidth and dc gain of the Op-Amp), aging, temperature variation, etc. A design methodology for this current sensor is proposed regarding all these effects. The sensing circuit is designed to mirror the actual capacitor current with a trans-impedance amplifier by matching phase and scaling impedances of the RLC network (C, ESR and ESL of the output capacitor). The proposed methodology has been validated by means of a buck converter switching at 5 MHz. Experimental results validate that the current sensor behaves appropriately under voltage and load steps.
引用
收藏
页码:806 / +
页数:2
相关论文
共 50 条
  • [1] A feasibility study for non-invasive thermometry using non-linear ultrasound
    van Dongen, Koen W. A.
    Verweij, Martin D.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2011, 27 (06) : 612 - 624
  • [2] Non-linear, non-invasive method for seizure anticipation in focal epilepsy
    Li, DZ
    Zhou, WP
    Drury, I
    Savit, R
    MATHEMATICAL BIOSCIENCES, 2003, 186 (01) : 63 - 77
  • [3] Validation of a non-invasive method to measure cardiac output in mice
    Tournoux, F.
    Thibault, H.
    Petersen, B.
    Raher, M. J.
    Halpern, E.
    Picard, M. H.
    Scherrer-Crosbie, M.
    EUROPEAN HEART JOURNAL, 2008, 29 : 793 - 793
  • [4] Non-invasive and fast control of neural activity
    Vogt, Nina
    NATURE METHODS, 2019, 16 (10) : 954 - 954
  • [5] Non-invasive and fast control of neural activity
    Nina Vogt
    Nature Methods, 2019, 16 : 954 - 954
  • [6] Linear and non-linear time series analysis in non-invasive physiological measurement.
    Carson, ER
    Leicester, HJ
    Roudsari, AV
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, : 489 - 495
  • [7] Microwave sensor for non-invasive glucose measurements design and implementation of a novel linear
    Baghbani, Rasool
    Rad, Masoomeh Ashoori
    Pourziad, Ali
    IET WIRELESS SENSOR SYSTEMS, 2015, 5 (02) : 51 - 57
  • [8] Em attack is non-invasive? - Design methodology and validity verification of EM attack sensor
    Homma, Naofumi
    Hayashi, Yu-Ichi
    Miura, Noriyuki
    Fujimoto, Daisuke
    Tanaka, Daichi
    Nagata, Makoto
    Aoki, Takafumi
    Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 2014, 8731
  • [9] EM Attack Is Non-invasive? - Design Methodology and Validity Verification of EM Attack Sensor
    Homma, Naofumi
    Hayashi, Yu-ichi
    Miura, Noriyuki
    Fujimoto, Daisuke
    Tanaka, Daichi
    Nagata, Makoto
    Aoki, Takafumi
    CRYPTOGRAPHIC HARDWARE AND EMBEDDED SYSTEMS - CHES 2014, 2014, 8731 : 1 - 16
  • [10] EM attack is non-invasive? - Design methodology and validity verification of EM attack sensor
    Homma, Naofumi
    Hayashi, Yu-Ichi
    Miura, Noriyuki
    Fujimoto, Daisuke
    Tanaka, Daichi
    Nagata, Makoto
    Aoki, Takafumi
    1600, Springer Verlag (8731):