Microfocusing options for the inelastic X-ray scattering beamline at sector 3 of the Advanced Photon Source

被引:0
|
作者
Alsmadi, A. M. [1 ,2 ,3 ]
Alatas, A. [3 ]
Zhao, J. Y. [3 ]
Hu, M. Y. [3 ]
Yan, L. [3 ]
Alp, E. E. [3 ]
机构
[1] Hashemite Univ, Dept Phys, Zarqa 13115, Jordan
[2] Kuwait Univ, Dept Phys, Safat 13060, Kuwait
[3] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
inelastic X-ray scattering; microfocusing options; KB mirrors; SHADOW ray tracing; SYNCHROTRON-RADIATION; RESOLUTION;
D O I
10.1107/S1600577514000940
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Synchrotron radiation from third-generation high-brilliance storage rings is an ideal source for X-ray microbeams. The aim of this paper is to describe a microfocusing scheme that combines both a toroidal mirror and Kirkpatrick-Baez (KB) mirrors for upgrading the existing optical system for inelastic X-ray scattering experiments at sector 3 of the Advanced Photon Source. SHADOW ray-tracing simulations without considering slope errors of both the toroidal mirror and KB mirrors show that this combination can provide a beam size of 4.5 mu m (H) x 0.6 mu m (V) (FWHM) at the end of the existing D-station (66 m from the source) with use of full beam transmission of up to 59%, and a beam size of 3.7 mu m (H) x 0.46 mu m (V) (FWHM) at the front-end of the proposed E-station (68 m from the source) with a transmission of up to 52%. A beam size of about 5 mu m (H) x 1 mu m (V) can be obtained, which is close to the ideal case, by using high-quality mirrors (with slope errors of less than 0.5 mu rad r.m.s.). Considering the slope errors of the existing toroidal and KB mirrors (5 and 2.9 mu rad r. m. s., respectively), the beam size grows to about 13.5 mu m (H) x 6.3 mu m (V) at the end of the D-station and to 12.0 mu(H) x 6.0 mu m (V) at the front-end of the proposed E-station. The simulations presented here are compared with the experimental measurements that are significantly larger than the theoretical values even when slope error is included in the simulations. This is because of the experimental set-up that could not yet be optimized.
引用
收藏
页码:488 / 496
页数:9
相关论文
共 50 条
  • [1] High resolution inelastic x-ray scattering spectrometer at the advanced photon source
    Schwoerer-Bohning, M
    Macrander, AT
    Abbamonte, PM
    Arms, DA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (09): : 3109 - 3112
  • [2] The Coherent X-ray Scattering Beamline at Taiwan Photon Source
    Lin, J.
    Huang, Y.
    Chen, C.
    Jeng, U.
    Mou, C.
    Lin, T.
    Chen, H.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C1747 - C1747
  • [3] High-energy-resolution inelastic X-ray scattering spectrometer at beamline 30-ID of the Advanced Photon Source
    Said, Ayman H.
    Sinn, Harald
    Toellner, Thomas S.
    Alp, Ercan E.
    Gog, Thomas
    Leu, Bogdan M.
    Bean, Sunil
    Alatas, Ahmet
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 827 - 835
  • [4] Soft x-ray spectroscopy undulator beamline at the Advanced Photon Source
    Randall, KJ
    Xu, ZD
    Moore, JF
    Gluskin, E
    GRATINGS AND GRATING MONOCHROMATORS FOR SYNCHROTRON RADIATION, 1997, 3150 : 189 - 194
  • [5] 121: an advanced high-resolution resonant inelastic X-ray scattering beamline at Diamond Light Source
    Zhou, Ke-Jin
    Walters, Andrew
    Garcia-Fernandez, Mirian
    Rice, Thomas
    Hand, Matthew
    Nag, Abhishek
    Li, Jiemin
    Agrestini, Stefano
    Garland, Peter
    Wang, Hongchang
    Alcock, Simon
    Nistea, Ioana
    Nutter, Brian
    Rubies, Nicholas
    Knap, Giles
    Gaughran, Martin
    Yuan, Fajin
    Chang, Peter
    Emmins, John
    Howell, George
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 563 - 580
  • [6] Conceptual design of the coherent X-ray scattering beamline at the taiwan photon source
    Huang, Yu-Shan
    Huang, Chi-Yi
    Chang, Chien-Hung
    Peng, Wen-Yan
    Jeng, U-Ser
    Mou, Chung-Yuan
    Lin, Tsang-Lang
    Chen, Hsin-Lung
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C442 - C442
  • [7] Beamline and exposure station for deep x-ray lithography at the advanced photon source
    Lai, B
    Mancini, DC
    Yun, W
    Gluskin, E
    MICROLITHOGRAPHY AND METROLOGY IN MICROMACHINING II, 1996, 2880 : 171 - 176
  • [8] Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source
    Ju, Guangxu
    Highland, Matthew J.
    Thompson, Carol
    Eastman, Jeffrey A.
    Fuoss, Paul H.
    Zhou, Hua
    Dejus, Roger
    Stephenson, G. Brian
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1036 - 1047
  • [9] A 2 m inelastic X-ray scattering spectrometer at CMC-XOR, advanced photon source
    Hill, J. P.
    Coburn, D. S.
    Kim, Y.-J.
    Gog, T.
    Casa, D. M.
    Kodituwakku, C. N.
    Sinn, H.
    JOURNAL OF SYNCHROTRON RADIATION, 2007, 14 : 361 - 365
  • [10] 2-ps Hard X-Ray Streak Camera Measurements at Sector 7 Beamline of the Advanced Photon Source
    Chollet, Matthieu
    Ahr, Brian
    Walko, Donald A.
    Rose-Petruck, Christoph
    Adams, Bernhard
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2012, 18 (01) : 66 - 73