A stable lyophilized reagent for use in a potential reference assay for quantitation of anti-D in immunoglobulin products

被引:7
|
作者
Thorpe, SJ
Fox, B
Sands, D
机构
[1] Natl Inst Biol Stand & Controls, Blanche Lane, Div Haematol, Potters Bar EN6 3QG, Herts, England
[2] Natl Inst Biol Stand & Controls, Blanche Lane, Div Informat, Potters Bar EN6 3QG, Herts, England
关键词
anti-D immunoglobulin; potency; immunoassay; stability;
D O I
10.1006/biol.2002.0347
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quality control of anti-D immunoglobulins intended for in vivo clinical use requires in vitro assay of potency, A lyophilized biotinylated monoclonal anti-D (biotinylated Brad-5; 99/698) has been evaluated for its suitability to serve as a working reagent in a competitive enzyme-linked immunoassay (EIA) for anti-D quantitation. The reagent demonstrated acceptable stability in accelerated degradation tests and following reconstitution. Twelve international laboratories obtained comparable potencies for each of nine anti-D samples using 99/698 in a standardized assay procedure using erythrocytes fixed to microtitre plates. We also describe the use of trehalose for stabilization of dried erythrocyte-coated microtitre plates. (C) 2002 The International Association for Biologicals. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:315 / 321
页数:7
相关论文
共 32 条
  • [1] REFERENCE PREPARATION FOR ASSAY OF ANTI-D IMMUNOGLOBULIN
    GUNSON, HH
    THOMAS, DP
    LANCET, 1979, 1 (8108): : 162 - 162
  • [2] ANTI-D IMMUNOGLOBULIN PREPARATIONS - STABILITY OF ANTI-D CONCENTRATIONS AND ERROR OF ASSAY OF ANTI-D
    HUGHESJONES, NC
    HUNT, VA
    MAYCOCK, WDA
    WESLEY, ED
    VALLET, L
    VOX SANGUINIS, 1978, 35 (1-2) : 100 - 104
  • [3] BROMELAIN SOLUTIONS FOR USE IN AUTOMATED ANTI-D QUANTITATION - A POTENTIAL HAZARD
    BOWELL, PJ
    CULLY, BJ
    YOUNG, NT
    MEDICAL LABORATORY SCIENCES, 1988, 45 (02): : 146 - 150
  • [4] Use of anti-D immunoglobulin in maternal trauma
    Eager, R
    Sutton, J
    Spedding, R
    Wallis, R
    EMERGENCY MEDICINE JOURNAL, 2003, 20 (05) : 498 - 498
  • [5] USE OF A RANGE EXPANDER IN AUTOMATED ANTI-D QUANTITATION
    COTTON, R
    SOBEY, DF
    VOX SANGUINIS, 1973, 24 (02) : 181 - 186
  • [6] Recommendations for the use of anti-D immunoglobulin for Rh prophylaxis
    Lee, D
    Contreras, M
    Robson, SC
    Rodeck, CH
    Whittle, MJ
    TRANSFUSION MEDICINE, 1999, 9 (01) : 93 - 97
  • [7] INTERNATIONAL COLLABORATIVE STUDY OF ASSAY OF ANTI-D (ANTI-RHO) IMMUNOGLOBULIN
    BANGHAM, DR
    KIRKWOOD, TBL
    WYBROW, G
    HUGHESJONES, NC
    GUNSON, HH
    BRITISH JOURNAL OF HAEMATOLOGY, 1978, 38 (03) : 407 - 423
  • [8] New reference reagent for the quality assurance of anti-D antibody detection
    Phillips, P
    Voak, D
    Downie, M
    Clark, N
    Miguta, J
    Rawlings, J
    Patel, B
    Redman, M
    TRANSFUSION MEDICINE, 1998, 8 (03) : 225 - 230
  • [9] A competitive enzyme-linked immunoassay using erythrocytes fixed to microtitre plates for anti-D quantitation in immunoglobulin products
    Thorpe, SJ
    Turner, CE
    Heath, AC
    Sands, D
    VOX SANGUINIS, 2000, 79 (02) : 100 - 107
  • [10] A REVIEW OF THE PRODUCTION AND CLINICAL USE OF INTRAVENOUS ANTI-D IMMUNOGLOBULIN
    WALSH, TJ
    ORIORDAN, JP
    IRISH MEDICAL JOURNAL, 1982, 75 (07) : 243 - 244