Insulation fault identification of vacuum circuit breakers based on improved MFCC and SVM

被引:0
|
作者
Luo, Linhuan [1 ]
Liu, Xiao [1 ]
Yan, Xiaohui [1 ]
机构
[1] Guangzhou Power Supply Bur China Southern Power G, Guangzhou, Guangdong, Peoples R China
关键词
D O I
10.1088/1742-6596/1176/6/062027
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Insulation faults in vacuum circuit breakers can produce physical phenomena such as visible sound, ultrasound, and electromagnetic waves. Through the real-time collection and analysis of the discharge sound during the internal insulation failure of the circuit breaker, the insulation state of the circuit breaker can be judged. This article proposes a method. The improved MFCC algorithm is used to extract the characteristic parameters of the discharge signal. The recognition of the flashover discharge sound signal is achieved by one-class SVM. The one-class SVM is constructed, so one-class SVM can be used to identify whether the signal is a surface discharge or not. The characteristic vectors of the audio signal of discharge have intrinsic similarity, and the distribution can be concentrated, which is significantly different from other abnormal sounds. The conclusion is verified by experimental data. The calculation results show that the it can effectively identify the insulation state of vacuum circuit breaker by the method of using of MFCC feature extraction based on Fisher criterion and one-class support vector machine.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fault Identification for Circuit Breakers Based on Vibration Measurements
    Yang, Qiuyu
    Ruan, Jiangjun
    Zhuang, Zhijian
    Huang, Daochun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 4154 - 4164
  • [2] GIS Insulation Defect Diagnosis Method Based on Improved MFCC and PCA-SVM Model
    Li, Binbin
    Cheng, Dengfeng
    Tian, Yu
    Zhu, Shenglong
    Luo, Sha
    2020 5TH INTERNATIONAL CONFERENCE ON COMMUNICATION, IMAGE AND SIGNAL PROCESSING (CCISP 2020), 2020, : 33 - 37
  • [3] An approach for intelligent detection and fault diagnosis of vacuum circuit breakers
    Ma, SH
    Wang, JM
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (02) : 226 - 229
  • [4] A method for intellectualized detection and fault diagnosis of vacuum circuit breakers
    Ma, SH
    Xu, JY
    Wang, JM
    ISDEIV: XIXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2000, 19 : 771 - 774
  • [5] Research on mechanical fault identification based on improved SVM
    Chen, Dongdi
    Xiang, Jiawei
    Zhong, Yongteng
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 4257 - 4260
  • [6] Application of EWT and PSO-SVM in Fault Diagnosis of HV Circuit Breakers
    Li, Bing
    Liu, Mingliang
    Guo, Zijian
    Ji, Yamin
    COMMUNICATIONS, SIGNAL PROCESSING, AND SYSTEMS, CSPS 2018, VOL III: SYSTEMS, 2020, 517 : 628 - 637
  • [7] Short-line fault interruption capability of vacuum circuit breakers
    Smeets, RPP
    van der Linden, WA
    ISDEIV: XXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, 2002, 20 : 34 - 37
  • [8] Overvoltage Impact on Internal Insulation Systems of Transformers in Electrical Networks with Vacuum Circuit Breakers
    Florkowski, Marek
    Furgal, Jakub
    Kuniewski, Maciej
    Pajak, Piotr
    ENERGIES, 2020, 13 (23)
  • [9] Fault Assessment of Circuit Breakers Based on Wide-Area Generalization Information and Improved ACGAN
    Sun, Shuguang
    Yang, Feilong
    Wang, Jingqin
    Li, Ruijie
    Wang, Zewei
    IEEE SENSORS JOURNAL, 2023, 23 (20) : 24954 - 24969
  • [10] Failure Diagnosis of High Voltage Circuit Breakers Based on GA and SVM
    Yuan, Jinli
    Li, Kui
    Guo, Zhitao
    Yue, Dawei
    Wang, Yao
    2011 INTERNATIONAL CONFERENCE ON MACHINE INTELLIGENCE (ICMI 2011), PT 1, 2011, 3 : 102 - 108