RADIATION PROTECTION MEASUREMENTS WITH THE VARIANCE-COVARIANCE METHOD IN THE STRAY RADIATION FIELDS FROM PHOTON AND PROTON THERAPY FACILITIES

被引:6
|
作者
Lillhok, J. [1 ]
Persson, L. [1 ]
Andersen, C. E. [2 ]
Dasu, A. [3 ]
Ardenfors, O. [4 ]
机构
[1] Swedish Radiat Safety Author, S-17116 Stockholm, Sweden
[2] Tech Univ Denmark, Ctr Nucl Technol, DK-4000 Roskilde, Denmark
[3] Skand Clin, S-75237 Uppsala, Sweden
[4] Stockholm Univ, Dept Phys, Med Radiat Phys, S-10691 Stockholm, Sweden
关键词
NEUTRON;
D O I
10.1093/rpd/ncx194
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The microdosimetric variance-covariance method was used to study the stray radiation fields from the photon therapy facility at the Technical University of Denmark and the scanned proton therapy beam at the Skandion Clinic in Uppsala, Sweden. Two TEPCs were used to determine the absorbed dose, the dose-average lineal energy, the dose-average quality factor and the dose equivalent. The neutron component measured by the detectors at the proton beam was studied through Monte Carlo simulations using the code MCNP6. In the photon beam the stray absorbed dose ranged between 0.3 and 2.4 mu Gy per monitor unit, and the dose equivalent between 0.4 and 9 mu Sv per monitor unit, depending on beam energy and measurement position. In the proton beam the stray absorbed dose ranged between 3 and 135 mu Gy per prescribed Gy, depending on detector position and primary proton energy.
引用
收藏
页码:338 / 341
页数:4
相关论文
共 24 条
  • [1] VARIANCE-COVARIANCE MEASUREMENTS IN THERAPEUTIC AND DIAGNOSTIC RADIATION BEAMS
    HONORE, HB
    JENSEN, LC
    JESSEN, KA
    NIELSEN, HH
    RADIATION PROTECTION DOSIMETRY, 1994, 52 (1-4) : 387 - 390
  • [2] Range-shifter effects on the stray field in proton therapy measured with the variance-covariance method
    Eliasson, Linda
    Lillhoek, Jan
    Baeck, Torbjoern
    Billnert-Maroti, Robert
    Dasu, Alexandru
    Liszka, Malgorzata
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [3] Radiation protection in proton therapy facilities
    Nystrom, H.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S164 - S165
  • [4] THE VARIANCE-COVARIANCE METHOD - MICRODOSIMETRY IN TIME-VARYING LOW DOSE-RATE RADIATION-FIELDS
    BRECKOW, J
    WENNING, A
    ROOS, H
    KELLERER, AM
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1988, 27 (04) : 247 - 259
  • [5] ON THE DETERMINATION OF MICRODOSIMETRIC PARAMETERS IN TIME-VARYING RADIATION-FIELDS - THE VARIANCE COVARIANCE METHOD
    KELLERER, AM
    ROSSI, HH
    RADIATION RESEARCH, 1984, 97 (02) : 237 - 245
  • [6] Measurements, Simulation, and Analytical Model of Stray Photon and Neutron Absorbed Dose from MV External Beam Radiation Therapy
    Schneider, C.
    Newhauser, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E470 - E470
  • [7] Effective Dose from Stray Radiation for a Patient Receiving Proton Therapy for Liver Cancer
    Taddei, Phillip J.
    Krishnan, Sunil
    Mirkovic, Dragan
    Yepes, Pablo
    Newhauser, Wayne D.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 445 - +
  • [8] Contemporary Proton Therapy Systems Adequately Protect Patients from Exposure to Stray Radiation
    Newhauser, Wayne D.
    Fontenot, Jonas D.
    Taddei, Phillip J.
    Mirkovic, Dragan
    Giebeler, Annelise
    Zhang, Rui
    Mahajan, Anita
    Kornguth, David
    Stovall, Marilyn
    Yepes, Pablo
    Woo, Shiao
    Mohan, Radhe
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 450 - +
  • [9] A REVIEW OF ANALYTICAL MODELS OF STRAY RADIATION EXPOSURES FROM PHOTON- AND PROTON-BEAM RADIOTHERAPIES
    Newhauser, W. D.
    Schneider, C.
    Wilson, L.
    Shrestha, S.
    Donahue, W.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 245 - 251
  • [10] Proton vs photon radiation therapy for glioblastoma: Maximizing information from trial
    Vogelius, Ivan R.
    Bentzen, Soren M.
    NEURO-ONCOLOGY, 2022, 24 (05) : 849 - 850