Marker-based versus model-based radiostereometric analysis of total knee arthroplasty migration: a reanalysis with comparable mean outcomes despite distinct types of measurement error

被引:17
|
作者
Van Hamersveld, Koen T. [1 ]
Marang-van de Mheen, Perla J. [2 ]
Koster, Lennard A. [1 ]
Nelissen, Rob G. H. H. [1 ]
Toksvig-Larsen, Soren [3 ,4 ]
Kaptein, Bart L. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Biomed Data Sci, Leiden, Netherlands
[3] Hassleholm Hosp, Dept Orthopaed, Hassleholm, Sweden
[4] Lund Univ, Dept Clin Sci, Lund, Sweden
关键词
RSA; BEARING;
D O I
10.1080/17453674.2019.1605692
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method, including insert micromotions in modular TKA and their effect on estimated group differences. Patients and methods - All patients had received a cemented Triathlon implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed (n = 28) tibial component. The latter group was reanalyzed with model-based RSA. Precision of each RSA method was calculated using double examinations. Bland-Altman plots were constructed to determine the limits of agreement between the 2 RSA methods. Polyethylene insert micromotion was quantified by measuring migration with respect to the metal tray. Finally, analyses of the original study were repeated with the model-based RSA results. Results - Systematic differences were found in translations between marker-based and model-based RSA as a result of different reference origins being used for migration calculations. Micromotions of the polyethylene insert within the metal tray were negligibly small. Mean migration results were comparable between marker-based and model-based RSA when using the same reference origin, even though conclusions on individual patients may differ between RSA methods due to various types of measurement error (e.g., marker occlusion and model-fit inaccuracies). Interpretation - At least for the studied TKA design, pooling mean migration data of different RSA methods appears justified. For translations, however, adjustments should be made to correct for differences in reference origin. Migration patterns of individual patients may differ as a result of distinct types of measurement error.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 14 条
  • [1] In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis
    Gascone, T.
    Parashin, S.
    Teeter, M.
    Bohm, E.
    Laende, E.
    Dunbar, M.
    Turgeon, T.
    BONE & JOINT JOURNAL, 2019, 101B (11): : 1348 - 1355
  • [2] Validation and Precision of Model-Based Radiostereometric Analysis (MBRSA) for Total Ankle Arthroplasty
    Fong, Jason Wai-Yip
    Veljkovic, Andrea
    Dunbar, Michael J.
    Wilson, David A.
    Hennigar, Allan W.
    Glazebrook, Mark A.
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (12) : 1155 - 1163
  • [3] Validation of In Vivo Linear and Volumetric Wear Measurement for Reverse Total Shoulder Arthroplasty Using Model-Based Radiostereometric Analysis
    Van de Kleut, Madeleine L.
    Yuan, Xunhua
    Athwal, George S.
    Teeter, Matthew G.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (07) : 1620 - 1627
  • [4] Error in maximum total point motion of a tibial baseplate is lower with a reverse-engineered model versus a CAD model using model-based radiostereometric analysis
    Niesen, Abigail E.
    Garverick, Anna L.
    Howell, Stephen M.
    Hull, Maury L.
    JOURNAL OF BIOMECHANICS, 2022, 143
  • [5] Stable glenoid component of reverse total shoulder arthroplasty at 2 years as measured with model-based radiostereometric analysis (RSA)
    Fraser, Alexander Nilsskog
    Boe, Berte
    Fjalestad, Tore
    Madsen, Jan Erik
    Rohrl, Stephan M.
    ACTA ORTHOPAEDICA, 2021, 92 (06) : 644 - 650
  • [6] Propagation of registration error into maximum total point motion to analyze tibial baseplate stability at six months using marker-based and model-based RSA
    Niesen, Abigail E.
    Hull, Maury L.
    JOURNAL OF BIOMECHANICS, 2021, 127
  • [7] The Cost-Effectiveness of Robotic-Assisted Versus Manual Total Knee Arthroplasty: A Markov Model-Based Evaluation
    Rajan, Prashant V. V.
    Khlopas, Anton
    Klika, Alison
    Molloy, Robert
    Krebs, Viktor
    Piuzzi, Nicolas S. S.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (04) : 168 - 176
  • [8] Early monitoring of inlay wear after total knee arthroplasty on plain radiographs using model-based wear measurement
    Emonde, Crystal Kayaro
    Hurschler, Christof
    Breuer, Andre
    Eggers, Max-Enno
    Wichmann, Marcel
    Ettinger, Max
    Denkena, Berend
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [9] Model-based pain and function outcome trajectory types for patients undergoing knee arthroplasty: a secondary analysis from a randomized clinical trial
    Dumenci, L.
    Perera, R. A.
    Keefe, F. J.
    Ang, D. C.
    Slover, J.
    Jensen, M. P.
    Riddle, D. L.
    OSTEOARTHRITIS AND CARTILAGE, 2019, 27 (06) : 878 - 884
  • [10] Reverse Total Shoulder Arthroplasty Versus Hemiarthroplasty for the Treatment of Proximal Humerus Fractures: A Model-Based Cost-Effectiveness Analysis
    Sheibani-Rad, Shahin
    Kuhn, Andrew W.
    Berrigan, Patrick S.
    Bedi, Asheesh
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (24) : E1353 - E1361