Sandwich-type electrochemical immunosensor for CEA detection based on Ag/MoS2@Fe3O4 and an analogous ELISA method with total internal reflection microscopy

被引:94
|
作者
Wang, Yaoguang [1 ]
Zhao, Guanhui [1 ]
Zhang, Yong [1 ]
Pang, Xuehui [1 ]
Cao, Wei [1 ]
Du, Bin [1 ,2 ]
Wei, Qin [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Key Lab Interfacial React & Sensing Anal Univ Sha, Jinan 250022, Shandong, Peoples R China
[2] Univ Jinan, Sch Resources & Environm, Jinan 250022, Shandong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Electrochemical immunosensor; Carcinoembryonic antigen; ELISA; Total internal reflection fluorescence; Ag/MoS2@Fe3O4; CARCINOEMBRYONIC ANTIGEN-DETECTION; PROSTATE-SPECIFIC ANTIGEN; REDUCED GRAPHENE OXIDE; LABEL-FREE; SHELL NANOPARTICLES; GOLD NANOPARTICLES; QUANTUM DOTS; FUNCTIONALIZED GRAPHENE; SENSITIVE DETECTION; MOS2; NANOSHEETS;
D O I
10.1016/j.snb.2018.03.178
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, an ultrasensitive electrochemical immunosensor was developed for detecting carcinoembryonic antigen (CEA) based on Ag/MoS2@Fe3O4 and an analogous enzyme linked immunosorbent assay (ELISA) method. The fabrication process was conducted by using 96-well microplate and the detection process was executed on magnetic glassy carbon electrode (MGCE), which was named analogous ELISA method. The technique of total internal reflection fluorescence (TIRF) was firstly employed to verify the feasibility of the proposed method. A sandwich-type strategy was applied for the fabrication of the immunosensor and Ag/MoS2@Fe3O4 was used as label. Simultaneously, Ag nanoparticles (Ag NPs) were applied for modifying the MGCE as sensing platform due to its excellent electroconductivity. Ag/MoS2@Fe3O4 could firmly attached on the surface of MGCE thanks to the magnetic property of Fe3O4. Differential pulse voltammetry (DPV) was applied for the detection of CEA and electrochemical impedance spectroscopy (EIS) confirmed the successful fabrication of the immunosensor. Under optimal experimental conditions, a linear response was achieved in the range of 0.0001-20 ng/mL with a low detection limit of 0.03 pg/mL. Furthermore, the proposed immunosensor exhibited good stability, excellent selectivity and fine reproducibility. This proposed strategy provides a new thought and a potential approach for clinical diagnosis of other tumor markers. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:561 / 569
页数:9
相关论文
共 39 条
  • [1] A sandwich-type electrochemical immunosensor for detecting CEA based on CeO2-MoS2 absorbed Pb2+
    Li, Wenjun
    Qiao, Xiuwen
    Hong, Chenglin
    Ma, Chaoyun
    Song, Yiju
    ANALYTICAL BIOCHEMISTRY, 2020, 592
  • [2] Sandwich-type electrochemical immunosensor based on CuFe2O4-Pd for cardiac troponin I detection
    Meng, Yaoyao
    Li, Yueyuan
    Liu, Shanghua
    Wang, Shujun
    Dong, Hui
    Jiang, Feng
    Liu, Qing
    Li, Yueyun
    Wei, Qin
    MICROCHIMICA ACTA, 2023, 190 (06)
  • [3] Sandwich-type electrochemical immunosensor based on CuFe2O4-Pd for cardiac troponin I detection
    Yaoyao Meng
    Yueyuan Li
    Shanghua Liu
    Shujun Wang
    Hui Dong
    Feng Jiang
    Qing Liu
    Yueyun Li
    Qin Wei
    Microchimica Acta, 2023, 190
  • [4] Sandwich-type electrochemical immunosensor for sensitive detection of CEA based on the enhanced effects of Ag NPs@CS spaced Hemin/rGO
    Zhang, Chunyan
    Zhang, Shuan
    Jia, Yilei
    Li, Yueyun
    Wang, Ping
    Liu, Qing
    Xu, Zhen
    Li, Xinjin
    Dong, Yunhui
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 785 - 791
  • [5] A Sandwich-Type Electrochemical Immunosensor based on Pd Nanocubes Functionalized MoO2 Nanospheres for Highly Sensitive Detection of CEA
    Yang, Qingshan
    Wang, Ping
    Zhou, Kaiwei
    Tang, Chunyuan
    Ren, Jie
    Li, Yueyun
    Liu, Qing
    Dong, Yunhui
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (16)
  • [6] Sandwich-type electrochemical immunoassay based on Co3O4@MnO2-thionine and pseudo-ELISA method toward sensitive detection of alpha fetoprotein
    Wang, Yaoguang
    Zhao, Guanhui
    Wang, Huan
    Cao, Wei
    Du, Bin
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2018, 106 : 179 - 185
  • [7] A sandwich-type electrochemical immunosensor for carcinoembryonic antigen based on signal amplification strategy of optimized ferrocene functionalized Fe3O4@SiO2 as labels
    Feng, Taotao
    Qiao, Xiuwen
    Wang, Haining
    Sun, Zhao
    Hong, Chenglin
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 48 - 54
  • [8] Sensitive detection of carcinoembryonic antigen (CEA) by a sandwich-type electrochemical immunosensor using MOF-Ce@HA/Ag-HRP-Ab2 as a nanoprobe
    Li, Wenjun
    Ma, Chaoyun
    Song, Yiju
    Hong, Chenglin
    Qiao, Xiuwen
    Yin, Bincheng
    NANOTECHNOLOGY, 2020, 31 (18)
  • [9] A novel and highly sensitive sandwich-type immunosensor for prostate-specific antigen detection based on MWCNTs-Fe3O4 nanocomposite
    Shamsazar, Ali
    Asadi, Asadollah
    Seifzadeh, Davod
    Mahdavi, Majid
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 346
  • [10] Enzyme-free sandwich-type electrochemical immunosensor for CEA detection based on the cooperation of an Ag/g-C3N4-modified electrode and Au@SiO2/Cu2O with core-shell structure
    Liao, Xiaochen
    Wang, Xiao
    Ma, Chaoyun
    Zhang, Li
    Zhao, Chulei
    Chen, Siyu
    Li, Keqiang
    Zhang, Mengmeng
    Mei, Lisha
    Qi, Yu
    Hong, Chenglin
    BIOELECTROCHEMISTRY, 2021, 142