Acoustic-speed correction of photoacoustic tomography by ultrasonic computed tomography based on optical excitation of elements of a full-ring transducer array

被引:1
|
作者
Xia, Jun [1 ]
Huang, Chao [1 ]
Maslov, Konstantin [1 ]
Anastasio, Mark A. [1 ]
Wang, Lihong V. [1 ]
机构
[1] Washington Univ, Dept Biomed Engn, St Louis, MO 63130 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014 | 2014年 / 8943卷
关键词
Ultrasound computed tomography; photoacoustic computed tomography; image reconstruction; speed of sound;
D O I
10.1117/12.2036615
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Photoacoustic computed tomography (PACT) is a hybrid technique that combines optical excitation and ultrasonic detection to provide high resolution images in deep tissues. In the image reconstruction, a constant speed of sound (SOS) is normally assumed. This assumption, however, is often not strictly satisfied in deep tissue imaging, due to acoustic heterogeneities within the object and between the object and coupling medium. If these heterogeneities are not accounted for, they will cause distortions and artifacts in the reconstructed images. In this paper, we incorporated ultrasonic computed tomography (USCT), which measures the SOS distribution within the object, into our full-ring array PACT system. Without the need for ultrasonic transmitting electronics, USCT was performed using the same laser beam as for PACT measurement. By scanning the laser beam on the array surface, we can sequentially fire different elements. As a first demonstration of the system, we studied the effect of acoustic heterogeneities on photoacoustic vascular imaging. We verified that constant SOS is a reasonable approximation when the SOS variation is small. When the variation is large, distortion will be observed in the periphery of the object, especially in the tangential direction.
引用
收藏
页数:6
相关论文
共 23 条
  • [1] Enhancement of photoacoustic tomography by ultrasonic computed tomography based on optical excitation of elements of a full-ring transducer array
    Xia, Jun
    Huang, Chao
    Maslov, Konstantin
    Anastasio, Mark A.
    Wang, Lihong V.
    OPTICS LETTERS, 2013, 38 (16) : 3140 - 3143
  • [2] Multiview Hilbert transformation in full-ring transducer array-based photoacoustic computed tomography
    Li, Lei
    Zhu, Liren
    Shen, Yuecheng
    Wang, Lihong V.
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (07)
  • [3] Image plane adjustment in photoacoustic tomography based on a full ring transducer array
    Ji, Zhong
    Ding, Wenzheng
    2016 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2016,
  • [4] Video-rate full-ring ultrasound and photoacoustic computed tomography with real-time sound speed optimization
    Zhang, Yachao
    Wang, Lidai
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (08) : 4398 - 4413
  • [5] Multi-view Hilbert transformation in full-ring-transducer-array based photoacoustic computed tomography (Conference Presentation)
    Li, Lei
    Li, Guo
    Zhu, Liren
    Xia, Jun
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2016, 2016, 9708
  • [6] Novel reconstruction algorithm of magnetoacoustic tomography based on ring transducer array for acoustic speed inhomogeneous tissues
    Wang, Lili
    Liu, Guoqiang
    Chen, Siping
    Chen, Xin
    Ma, Xibo
    Xia, Hui
    MEDICAL PHYSICS, 2020, 47 (08) : 3533 - 3544
  • [7] X-ray-induced acoustic computed tomography with an ultrasound transducer ring-array
    Tang, S.
    Nguyen, D. H.
    Zarafshani, A.
    Ramseyer, C.
    Zheng, B.
    Liu, H.
    Xiang, L.
    APPLIED PHYSICS LETTERS, 2017, 110 (10)
  • [8] A High-Speed Photoacoustic Tomography System based on a Commercial Ultrasound and a Custom Transducer Array
    Wang, Xueding
    Cannata, Jonathan
    DeBusschere, Derek
    Hu, Changhong
    Fowlkes, J. Brian
    Carson, Paul
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [9] Large-scale surface-micromachined optical ultrasound transducer (SMOUT) array for photoacoustic computed tomography
    Yan, Zhiyu
    Zou, Jun
    OPTICS EXPRESS, 2022, 30 (11) : 19069 - 19080
  • [10] Circular array transducer based-photoacoustic/ultrasonic endoscopic imaging with tunable ring-beam excitation
    Xie, Zhihua
    Liu, Jiamei
    Ren, Yaguang
    Huang, Jiqing
    Lin, Riqiang
    Wang, Xiatian
    Tan, Qingyuan
    Lv, Shengmiao
    Song, Liang
    Liu, Chengbo
    Ma, Teng
    Gong, Xiaojing
    PHOTOACOUSTICS, 2023, 29