Towards an analytic solution for pulsed CEST

被引:15
|
作者
Gochberg, Daniel F. [1 ,2 ,3 ]
Does, Mark D. [1 ,2 ,4 ,5 ]
Zu, Zhongliang [1 ,2 ]
Lankford, Christopher L. [1 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, 1161 21 Ave S,MCN AAA-3112, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[5] Vanderbilt Univ, Dept Elect Engn, Nashville, TN 37235 USA
关键词
analytic; CERT; CEST; exchange; AMIDE PROTON-TRANSFER; CHEMICAL-EXCHANGE; MAGNETIZATION-TRANSFER; IN-VIVO; RELAXATION; PH;
D O I
10.1002/nbm.3903
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chemical exchange saturation transfer (CEST) is an imaging method based on magnetization exchange between solutes and water. This exchange generates changes in the measured signal after off-resonance radiofrequency irradiation. Although the analytic solution for CEST with continuous wave (CW) irradiation has been determined, most studies are performed using pulsed irradiation. In this work, we derive an analytic solution for the CEST signal after pulsed irradiation that includes both short-time rotation effects and long-time saturation effects in a two-pool system corresponding to water and a low-concentration exchanging solute pool. Several approximations are made to balance the accuracy and simplicity of the resulting analytic form, which is tested against numerical solutions of the coupled Bloch equations and is found to be largely accurate for amides at high fields, but less accurate at the higher exchange rates, lower offsets and typically higher irradiation powers of amines.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A hybrid numeric-analytic solution for pulsed CEST
    Lankford, Christopher L.
    Louie, Elizabeth A.
    Zu, Zhongliang
    Does, Mark D.
    Gochberg, Daniel F.
    NMR IN BIOMEDICINE, 2022, 35 (01)
  • [2] Analytic solution for plasma dynamics in a small, pulsed bore
    Sheridan, TE
    PHYSICS OF PLASMAS, 1997, 4 (09) : 3442 - 3444
  • [3] Understanding Quantitative Pulsed CEST in the Presence of MT
    Desmond, Kimberly L.
    Stanisz, Greg J.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 979 - 990
  • [4] Presaturation Power Adjusted Pulsed CEST: A Method to Increase Independence of Target CEST Signals
    Kikuchi, Kazufumi
    Ishimatsu, Keisuke
    Zhang, Shanrong
    Dimitrov, Ivan E.
    Honda, Hiroshi
    Sherry, A. Dean
    Takahashi, Masaya
    CONTRAST MEDIA & MOLECULAR IMAGING, 2018,
  • [5] Analytic Solution of the Approach of Quantum Vortices Towards Reconnection
    Boue, Laurent
    Khomenko, Dmytro
    L'vov, Victor S.
    Procaccia, Itamar
    PHYSICAL REVIEW LETTERS, 2013, 111 (14)
  • [6] Analytic solution for low-frequency rf sheaths in pulsed discharges
    Waelbroeck, FL
    PHYSICAL REVIEW E, 2002, 65 (06): : 1 - 066407
  • [7] Quantitative pulsed CEST-MRI using Ω-plots
    Meissner, Jan-Eric
    Goerke, Steffen
    Rerich, Eugenia
    Klika, Karel D.
    Radbruch, Alexander
    Ladd, Mark E.
    Bachert, Peter
    Zaiss, Moritz
    NMR IN BIOMEDICINE, 2015, 28 (10) : 1196 - 1208
  • [8] Towards an analytic solution of rapid roll inflation with a quartic potential
    Lin, Chia-Min
    CHINESE JOURNAL OF PHYSICS, 2019, 61 : 98 - 103
  • [9] Towards quantification of pulsed spinlock and CEST at clinical MR scanners: an analytical interleaved saturation-relaxation (ISAR) approach
    Roeloffs, Volkert
    Meyer, Christian
    Bachert, Peter
    Zaiss, Moritz
    NMR IN BIOMEDICINE, 2015, 28 (01) : 40 - 53
  • [10] Quasi-steady-state CEST (QUASS CEST) solution improves the accuracy of CEST quantification: QUASS CEST MRI-based omega plot analysis
    Sun, Phillip Zhe
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 765 - 776