Center Effect on Ankle-Brachial Index Measurement when Using the Reference Method (Doppler and Manometer): Results From a Large Cohort Study

被引:8
|
作者
Vierron, Emilie [1 ,2 ,4 ,5 ]
Halimi, Jean-Michel [2 ,3 ]
Tichet, Jean [6 ]
Balkau, Beverley [7 ,8 ]
Cogneau, Joel [9 ]
Giraudeau, Bruno [1 ,2 ,4 ,5 ]
机构
[1] INSERM, CIC 202, Tours, France
[2] Univ Tours, Tours, France
[3] CHRU Tours, Serv Nephrol Immunol Clin, Tours, France
[4] INSERM, U717, Paris, France
[5] Univ Paris Sud, UMR S717, Paris, France
[6] Inst Inter Reg Sante, La Riche, France
[7] INSERM, U780, Villejuif, France
[8] Univ Paris Sud, UMR S780, Villejuif, France
[9] IRMG, Paris, France
关键词
INTRACLASS CORRELATION-COEFFICIENT; PRESSURE INDEX; REPRODUCIBILITY; RELIABILITY; PHYSICIANS; DISEASE; UTILITY;
D O I
10.1038/ajh.2009.78
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND The ankle-brachial index (ABI) is a simple and noninvasive tool used to detect peripheral arterial disease (PAD). We aimed to assess, in a French multicenter cohort, the center effect associated with arterial pressure (AP) and ABI measurements using the reference method and using a semiautomatic device. METHODS This study included baseline and 9-year follow-up data from 3,664 volunteers of 10 health examination centers of the DESIR (Data from an Epidemiological Study on the Insulin Resistance) syndrome French cohort. Ankle and brachial AP were measured at inclusion by the reference method (a mercury sphygmomanometer coupled with a Doppler probe for ankle measurements) and at 9 years by a semiautomatic device (Omron HEM-705CP). The center effect was assessed by the intraclass correlation coefficient (ICC), ratio of the between-center variance to the total variance of the measurement. RESULTS At inclusion, the sample mean age was 47.5 (s.d. 9.9) years; 49.3% were men. Although ICCs were smaller than 0.05 for brachial AP measurements, they were close to 0.18 and 0.20 for ankle systolic AP (SAP) and ABI measurements, respectively, when the reference method was used. No center effect for measures other than ankle SAP was detected. With the semiautomatic device method, all ICCs, including those for ankle SAP and ABI measurements, were between 0.005 and 0.04. CONCLUSIONS We found an important center effect on ABI measured with a sphygmomanometer and a Doppler probe but not a semiautomatic device. A center effect should be taken into account when planning any multicenter study on ABI measurement.
引用
收藏
页码:718 / 722
页数:5
相关论文
共 33 条
  • [1] Automated plethysmographic measurement of the ankle-brachial index: a comparison with the doppler ultrasound method
    Jane H Davies
    E Mark Williams
    Hypertension Research, 2016, 39 : 100 - 106
  • [2] Automated plethysmographic measurement of the ankle-brachial index: a comparison with the doppler ultrasound method
    Davies, Jane H.
    Williams, E. Mark
    HYPERTENSION RESEARCH, 2016, 39 (02) : 100 - 106
  • [3] Measurement characteristics of the ankle-brachial index: results from the Action for Health in Diabetes study
    Espeland, Mark A.
    Regensteiner, Judith G.
    Jaramillo, Sarah A.
    Gregg, Edward
    Knowler, William C.
    Wagenknecht, Lynne E.
    Bahnson, Judy
    Haffner, Steven
    Hill, James
    Hiatt, William R.
    VASCULAR MEDICINE, 2008, 13 (03) : 225 - 233
  • [4] Atrial fibrillation does not affect ankle-brachial index measured using the Doppler method
    Dabrowski, Michal
    Lewandowski, Jacek
    Abramczyk, Piotr
    Lon, Izabela
    Gaciong, Zbigniew
    Sinski, Maciej
    HYPERTENSION RESEARCH, 2018, 41 (01) : 60 - 65
  • [5] Oscillometric measurement of ankle-brachial index in patients with suspected peripheral vascular disease: comparison with Doppler method
    Diehm, Nicolas
    Dick, Florian
    Czuprin, Carsten
    Lawall, Holger
    Baumgartner, Iris
    Diehm, Curt
    SWISS MEDICAL WEEKLY, 2009, 139 (25-26) : 357 - 363
  • [6] An algorithm to determine the ankle-brachial pressure index using the oscillometric blood pressure measurement method
    Meza, Marko
    Susteric, Jakob
    Krivic, Tomo
    Tasic, Jurij F.
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2011, 78 (03): : 159 - 164
  • [7] An algorithm to determine the ankle-brachial pressure index using the oscillometric blood pressure measurement method
    Meža, Marko
    Šušterič, Jakob
    Krivic, Tomo
    Tasič, Jurij F.
    Elektrotehniski Vestnik/Electrotechnical Review, 2011, 78 (03): : 136 - 141
  • [8] Are intermediate ankle-brachial index values important? Insights from a large cohort of never-treated hypertensives
    Xaplanteris, P.
    Vlachopoulos, C.
    Pietri, P.
    Ioakeimidis, N.
    Abdelrasoul, M.
    Aggelakas, A.
    Vyssoulis, G.
    Stefanadis, C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 629 - 629
  • [9] Decline in ankle-brachial index is stronger in poorly than in well controlled diabetes: Results from the Heinz Nixdorf Recall cohort study
    Kowall, Bernd
    Erbel, Raimund
    Moebus, Susanne
    Lehmann, Nils
    Kroeger, Knut
    Stang, Andreas
    ATHEROSCLEROSIS, 2019, 284 : 37 - 43
  • [10] How cognitive performance changes according to the ankle-brachial index score in an elderly cohort? Results from the Toledo Study of Healthy Ageing
    Bareiro, Fabio A. Quinonez
    Carnicero, Jose A.
    Acha, Ana Alfaro
    Artalejo, Cristina Rosado
    Jimenez, Maria C. Grau
    Manas, Leocadio Rodriguez
    Garcia, Francisco J. Garcia
    GEROSCIENCE, 2024, 46 (01) : 609 - 620