In vitro performance of zirconia and titanium implant/abutment systems for anterior application

被引:42
|
作者
Rosentritt, Martin [1 ]
Hagemann, Anna [1 ]
Hahnel, Sebastian [1 ]
Behr, Michael [1 ]
Preis, Verena [1 ]
机构
[1] Univ Med Ctr Regensburg, Dept Prosthet Dent, D-93042 Regensburg, Germany
关键词
Implant; Abutment; Zirconia; Titanium; Chewing simulation; Fracture resistance; ALL-CERAMIC RESTORATIONS; FRACTURE-RESISTANCE; SINGLE-TOOTH; IMPLANT ABUTMENTS; DENTAL IMPLANTS; STRENGTH; FAILURE; SUCCESS; LOAD;
D O I
10.1016/j.jdent.2014.03.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate the type of failure and fracture resistance behaviour of different zirconia and titanium implant/abutment systems for anterior application. Methods: Eight groups of implant-abutment combinations (n = 8/system) were restored with identical full-contour zirconia crowns. The systems represented one-piece and multi-piece zirconia (Z) or titanium (T) implants/abutments with different types of connection (screwed = 5, bonded = B). The following combinations (implant-abutment-connection) were investigated: ZZS, ZZB, ZZZB (three-piece), ZTS, TTS, TTS reference, and Z (one-piece, 2x). To simulate clinical anterior loading situations the specimens were mounted into the chewing simulator at an angle of 135 degrees and subjected to thermal cycling (2 x 3000 x 5 degrees/ 55 degrees C) and mechanical loading (1.2 x 10(6) x 50 N; 1.6 Hz). Fracture resistance and maximum bending stress were determined for all specimens that survived ageing. Data were statistically analyzed with the Kolmogorov-Smimov-test and one-way ANOVA (alpha = 0.05). Survival performance was calculated with the Kaplan-Meier Log-Rank test. Results: Independent of the material combinations screwed systems showed partly failures of the screws during simulation (ZZS: 3x, ZTS: 8x, TTS: 3x). Screw failures were combined with implant/abutment fractures of zirconia systems. Zirconia one-piece implants and the reference system did not show any failures, and only one specimen of the systems with a bonded connection (ZZZB) fractured. Mean (+/- standard deviation) fracture forces and maximum bending stresses differed significantly (p = 0.000) between 187.4 +/- 42.0 N/ 250.0 +/- 56.0 N/mm(2) (ZZZB) and 524.3 +/- 43.1 N/753.0 +/- 61.0 N/mm(2) (Z). Conclusions: Both material (zirconia or titanium) and the type of connection influenced failure resistance during fatigue testing, fracture force, and maximum bending stress. Clinical significance: Different material combinations for implants and abutments as well as different types of connection achieved acceptable or even good failure and fracture resistance that may be satisfactory for anterior clinical application. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1019 / 1026
页数:8
相关论文
共 50 条
  • [1] In vitro performance of two-piece zirconia implant systems for anterior application
    Preis, Verena
    Kammermeier, Armin
    Handel, Gerhard
    Rosentritt, Martin
    DENTAL MATERIALS, 2016, 32 (06) : 765 - 774
  • [2] In vitro performance of one- and two-piece zirconia implant systems for anterior application
    Kammermeier, Armin
    Rosentritt, Martin
    Behr, Michael
    Schneider-Feyrer, Sibylle
    Preis, Verena
    JOURNAL OF DENTISTRY, 2016, 53 : 94 - 101
  • [3] Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: A comparative in vitro study
    Stimmelmayr, Michael
    Edelhoff, Daniel
    Gueth, Jan-Frederik
    Erdelt, Kurt
    Happe, Arndt
    Beuer, Florian
    DENTAL MATERIALS, 2012, 28 (12) : 1215 - 1220
  • [4] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Disayut Klongbunjit
    Weerapan Aunmeungtong
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 7
  • [5] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Klongbunjit, Disayut
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [6] Fracture of Zirconia Abutment with Metallic Insertion on Anterior Single Titanium Implant with Internal Hexagon: Retrieval Analysis of a Failure
    Bottino, Marco Antonio
    Villefort Rocha, Regina Furbino
    Anami, Lilian Costa
    Ozcan, Mutlu
    de Melo, Renata Marques
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2016, 24 (03): : 164 - 168
  • [7] Titanium implant wear from a zirconia custom abutment: A clinical report
    Mizumoto, Ryan M.
    Malamis, Dimitrios
    Mascarenhas, Faye
    Tatakis, Dimitris N.
    Lee, Damian J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02): : 201 - 205
  • [8] A custom titanium abutment for the anterior single-tooth implant
    Marchack, CB
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (03): : 288 - 291
  • [9] A Case of Anterior Single Tooth Implant with Fractured Zirconia Abutment due to Trauma
    Yotsuya, Mamoru
    Nakano, Masahiro
    Umehara, Kazuhiro
    Awazawa, Shigeki
    Nomura, Takao
    Kuribayashi, Nobuyuki
    Yoshinari, Masao
    Sekine, Hideshi
    BULLETIN OF TOKYO DENTAL COLLEGE, 2024, 65 (2-3): : 31 - 40
  • [10] Wear at the Titanium-Zirconia Implant-Abutment Interface: A Pilot Study
    Klotz, Michael W.
    Taylor, Thomas D.
    Goldberg, A. Jon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (05) : 970 - 975