Development of a 10 m long 1 kA 66/77 kV YBCO HTS cable with low AC loss and a joint with low electrical resistance

被引:17
|
作者
Yagi, Masashi [1 ]
Mukoyama, Shinichi [1 ]
Amemiya, Naoyuki [2 ]
Kashima, Naoji [3 ]
Nagaya, Shigeo [3 ]
Shiohara, Yuh [4 ]
机构
[1] Furukawa Elect Corp Ltd, Energy Transmiss Res Dept, Ecol & Energy Lab, Chiba 2908555, Japan
[2] Kyoto Univ, Grad Sch Engn, Dept Elect Engn, Nishikyo Ku, Kyoto 6158510, Japan
[3] Chubu Elect Power Co Inc, Midori Ku, Nagoya, Aichi 4598522, Japan
[4] Supercond Res Lab, Koto Ku, Tokyo 1350062, Japan
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2009年 / 22卷 / 08期
关键词
POWER TRANSMISSION CABLES; COATED CONDUCTORS; PROJECT; PROGRESS; SYSTEM; MVA;
D O I
10.1088/0953-2048/22/8/085003
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have developed high-T(c) superconducting (HTS) cables using YBCO tapes. A 10 mm-wide YBCO tape was divided into five strips using a YAG laser to reduce AC loss. A 0.3 m conductor and a 1 m conductor were fabricated achieving AC losses at 1 kA(rms) and 50 Hz of 0.054 W m(-1) and of 0.048 W m(-1), respectively. Based on the successful AC loss reduction in the 0.3 and 1 m conductors, we fabricated a 10 m HTS cable with a three-layer HTS conductor, electrical insulation, and a one-layer HTS shield. The AC loss in this 10 m HTS conductor was 0.090 W m(-1) at 1 kA(rms) and 50 Hz. An HTS cable joint was designed and fabricated that included a three-layer HTS conductor and a one-layer HTS shield. Joint resistance of 5.2 n Omega for the HTS conductor and that of 10 n Omega for the HTS shield were achieved. The HTS cable joint was compact and had sufficient withstand voltage properties for 66/77 kV. In addition, we also confirmed the efficiency of joint construction. Moreover, a 20 m long HTS cable was successfully constructed and tested in January 2008. This HTS cable consisted of two 10 m HTS cables and the HTS cable joint. One 10 m HTS cable using HoBCO was made by Sumitomo, and the HTS cable joint and the other 10 m cable using IBAD YBCO were made by Furukawa and Chubu. The electrical resistance of the HTS cable joint was less than 10 n Omega, and the 20 m HTS cable including the joint withstood an over-current of 31.5 kA(rms) whose duration was 2 s.
引用
收藏
页数:9
相关论文
共 4 条
  • [1] Design of a 30 m long 1 kA 10 kV YBCO cable
    Rostila, L
    Lehtonen, J
    Masti, M
    Lallouet, N
    Saugrain, JM
    Allais, A
    Schippl, K
    Schmidt, F
    Balog, G
    Marot, G
    Ravex, A
    Usoskin, A
    Gömöry, F
    Klincok, B
    Souc, J
    Freyhardt, HC
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2006, 19 (04): : 418 - 422
  • [2] Low AC loss in a 3 kA HTS cable of the Dutch project
    Chevtchenko, Oleg
    Zuijderduin, Roy
    Smit, Johan
    Willen, Dag
    Lentge, Heidi
    Thidemann, Carsten
    Traeholt, Chresten
    Melnik, Irina
    Geschiere, Alex
    SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 : 1285 - 1289
  • [3] A Novel Electrical Insulating Material for 275 kV High-Voltage HTS Cable with Low Dielectric Loss
    Hayakawa, N.
    Nishimachi, S.
    Maruyama, O.
    Ohkuma, T.
    Liu, J.
    Yagi, M.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [4] EFFECT OF CYCLE ASYMMETRY AND LONG-TERM AGING ON LOW-CYCLE FRACTURE RESISTANCE OF A WELDED JOINT IN STEEL 15KH1M1F
    KLYKOVA, GI
    SHNAIDER, MA
    WELDING PRODUCTION, 1975, 22 (02): : 26 - 27