Wide scan imaging with swept-source optical coherent tomography for glaucoma diagnosis

被引:10
|
作者
Hong, Eun Hee [1 ]
Shin, Yong Un [1 ]
Kang, Min Ho [1 ]
Cho, Heeyoon [1 ]
Seong, Mincheol [1 ]
机构
[1] Hanyang Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
来源
PLOS ONE | 2018年 / 13卷 / 04期
基金
新加坡国家研究基金会;
关键词
CHOROIDAL THICKNESS; PROGRESSION; ABILITY; VOLUME; DAMAGE;
D O I
10.1371/journal.pone.0195040
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To determine glaucoma-discriminating abilities of macular and circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements of wide scan (12X9mm) using swept-source optical coherence tomography (SS-OCT) compared to measurements of standard macula and disc scans (6 X 6 mm). Methods This retrospective chart review study included 60 glaucomatous and 62 healthy eyes of total 122 subjects who visited a glaucoma clinic and were examined with wide, standard macula, and standard disc scans of SS-OCT (DRI-OCT-1 Atlantis; Topcon Inc., Tokyo, Japan) on the same day. Thickness measurements of the ganglion cell layer plus inner plexiform layer (mGCIPL), mGCIPL plus nerve fiber layer (mGCC), and total retinal layer (TRL) were assessed in wide and standard macula scans. Thickness measurements of cpRNFL were assessed in wide and standard disc scans. The repeatability and agreement of measurements taken in each scan were evaluated using intraclass correlation coefficients (ICCs). The abilities of parameters to discriminate between glaucoma and normal groups were assessed using areas under receiver operating characteristic curves (AUCs). Results The repeatability and agreement of all parameters showed high ICC values (all >= 0.800). AUCs for mGCIPL thickness were 0.710-0.847 and 0.701-0.836 in standard macula and wide scans, respectively. AUCs for cpRNFL thickness were 0.749-0.902 and 0.726-0.897 in standard disc and wide scans, respectively. There were no significant differences in AUCs between wide and standard scans. Conclusions The agreement between SS-OCT wide and standard scans for mGCIPL, mGCC and cpRNFL measurements were excellent. As the glaucoma-discriminating ability of wide scans was comparable to that of standard macula/disc scans, a single wide scan can replace separate standard macula/disc scans for evaluating glaucoma.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Evaluation of glaucoma filtering blebs with a swept-source Optical Coherence Tomography
    Milla, Elena
    Zarranz-Ventura, Javier
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGING OF THE CHORIOCAPILLARIS
    Ledesma-Gil, Gerardo
    Fernandez-Avellaneda, Pedro
    Spaide, Richard F.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (07): : 1373 - 1378
  • [3] Swept-source optical coherence tomography imaging of the retinochoroid and beyond
    Vira, Jayesh
    Marchese, Alessandro
    Singh, Rohan Bir
    Agarwal, Aniruddha
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (05) : 413 - 426
  • [4] Diagnostic Ability of Retinal Nerve Fiber Layer Imaging by Swept-Source Optical Coherence Tomography in Glaucoma
    Yang, Zhiyong
    Tatham, Andrew J.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Zhang, Chunwei
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 193 - 201
  • [5] Characterization of optical fiber imaging bundles for swept-source optical coherence tomography
    Ford, Helen D.
    Tatam, Ralph P.
    APPLIED OPTICS, 2011, 50 (05) : 627 - 640
  • [6] Subgingival calculus imaging based on swept-source optical coherence tomography
    Hsieh, Yao-Sheng
    Ho, Yi-Ching
    Lee, Shyh-Yuan
    Lu, Chih-Wei
    Jiang, Cho-Pei
    Chuang, Ching-Cheng
    Wang, Chun-Yang
    Sun, Chia-Wei
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (07)
  • [7] Asymmetry Analysis of Macular Inner Retinal Layers for Glaucoma Diagnosis: Swept-Source Optical Coherence Tomography Study
    Lee, Sang-Yoon
    Lee, Eun Kyoung
    Park, Ki Ho
    Kim, Dong Myung
    Jeoung, Jin Wook
    PLOS ONE, 2016, 11 (10):
  • [8] Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: Measuring Peripheral Anterior Synechia in Glaucoma
    Lai, Isabel
    Mak, Heather
    Lai, Gilda
    Yu, Marco
    Lam, Dennis S. C.
    Leung, Christopher K. S.
    OPHTHALMOLOGY, 2013, 120 (06) : 1144 - 1149
  • [9] Swept-Source Anterior Segment Optical Coherence Tomography Imaging and Quantification of Bleb Parameters in Glaucoma Filtration Surgery
    Tan, Jeremy C. K.
    Muntasser, Hussameddin
    Choudhary, Anshoo
    Batterbury, Mark
    Vallabh, Neeru A.
    BIOENGINEERING-BASEL, 2023, 10 (10):
  • [10] Three-Dimensional Imaging of Lamina Cribrosa Defects in Glaucoma Using Swept-Source Optical Coherence Tomography
    Takayama, Kohei
    Hangai, Masanori
    Kimura, Yugo
    Morooka, Satoshi
    Nukada, Masayuki
    Akagi, Tadamichi
    Ikeda, Hanako Ohashi
    Matsumoto, Akiko
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4798 - 4807