A highly sensitive method for quantification of iohexol

被引:5
|
作者
Schulz, Anna [1 ]
Boeringer, Falk [1 ]
Swifka, Janine [2 ]
Kretschmer, Axel [2 ]
Schaefer, Mandy [1 ]
Jankowski, Vera [1 ,3 ]
van der Giet, Markus [1 ]
Schuchardt, Mirjam [1 ]
Toelle, Markus [1 ]
Tepel, Martin [4 ]
Schlieper, George [5 ]
Zidek, Walter [1 ]
Jankowski, Joachim [1 ,3 ]
机构
[1] Charite Univ Med Berlin CBF, Med Klin 4, D-12200 Berlin, Germany
[2] Bayer Pharma AG, Global Drug Discovery Clin Sci, Wuppertal, Germany
[3] Univ Klinikum RWTH Aachen, Inst Mol Cardiovasc Res IMCAR, Aachen, Germany
[4] Univ Southern Denmark, Inst Mol Med, Odense, Denmark
[5] Univ Klinikum RWTH Aachen, Med Klin 2, Aachen, Germany
关键词
GLOMERULAR-FILTRATION-RATE; CHRONIC KIDNEY-DISEASE; IODINATED CONTRAST MATERIAL; PLASMA-CLEARANCE; INDUCED NEPHROPATHY; RENAL-FAILURE; CHILDREN; INULIN; VALIDATION; LOHEXOL;
D O I
10.1039/c4ay00174e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
lohexol (1-N,3-N-bis(2,3-dihydroxypropyl)-5-IN-(2,3-dihydroxypropyl) acetamide-2,4,6-triiodobenzene1,3-dicarboxamide) is used for accurate determination of the glomerular filtration rate (GFR) in chronic kidney disease (CKD) patients. However, high iohexol amounts might lead to adverse effects in organisms. In order to minimize the iohexol dosage required for the GFR determination in humans, the development of a sensitive quantification method is essential. Therefore, the objective of our preclinical study was to establish and validate a simple and robust liquid-chromatography-electrospray-massspectrometry (LC-ESI-MS) approach using the multiple reaction monitoring mode for iohexol quantification. In order to test whether a significantly decreased amount of iohexol is sufficient for reliable quantification, a LC-ESI-MS approach was assessed. We analyzed the kinetics of iohexol in rats after application of different amounts of iohexol (15 mg to 150 1.tg per rat). Blood sampling was conducted at four time points, at 15, 30, 60, and 90 min, after iohexol injection. The analyte (iohexol) and the internal standard (iotha(amic acid) were separated from serum proteins using a centrifugal filtration device with a cut-off of 3 kDa. The chromatographic separation was achieved on an analytical Zorbax SB C18 column. The detection and quantification were performed on a high capacity trap mass spectrometer using positive ion ESI in the multiple reaction monitoring (MRM) mode. Furthermore, using real-time polymerase chain reaction (RTPCR) the effect of iohexot on early regulated gene expression in thyroid and renal cortex was tested to determine a threshold of physiological active iohexol concentrations. A linear correlation of the iohexol amount and mass-signal (MS) intensity was found in the range of 50 pg to 40 ng (r2 = 0.998). The lowest limit of quantification (LLOQ) was 50 pg. The intraand inter-day accuracies were between 91.2% and 98.7%. The intra- and inter-day precisions were between 2.7% and 9.2%. The recovery rate of iohexol was determined in the range of 100.8 10.9%. The gene expression test revealed that iohexot dosages exceeding 0.5 mg kg-1 induce a group of genes in thyroidal tissue that comprises transcription factors and genes of cellular stress response. Namely, Ptgs2, Smad7, Jun, Srf, Dusp1, Timp1 and others are up-regulated within 15 min after iohexol iv. application. This mass-spectrometry based method has been proved to be sensitive, selective and suitable for the quantification of iohexol in serum. Due to high sensitivity of this novel method the iohexol application dose as well as the sampling time in the clinical routine could be reduced in the future in order to further minimize side effects in humans.
引用
收藏
页码:3706 / 3712
页数:7
相关论文
共 50 条
  • [1] HIGHLY SENSITIVE METHOD FOR QUANTIFICATION OF IOHEXOL
    Jankowski, Joachim
    Schulz, Anna
    Jankowski, Vera
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [2] Quantification of human serum albumin by highly sensitive chemiluminescence method
    Xu, Wei
    Wei, Yanchun
    Xing, Da
    Chen, Qun
    Luo, Shiming
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1694 - +
  • [3] Multiplex biosensing with highly sensitive magnetic nanoparticle quantification method
    Nikitin, M. P.
    Orlov, A. V.
    Znoyko, S. L.
    Bragina, V. A.
    Gorshkov, B. G.
    Ksenevich, T. I.
    Cherkasov, V. R.
    Nikitin, P. I.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2018, 459 : 260 - 264
  • [4] A NOVEL HIGHLY SENSITIVE ELECTROPHORETIC METHOD FOR THE DETECTION AND QUANTIFICATION OF PROTEINASE ACTIVITY
    POULSEN, OM
    HAU, J
    ELECTROPHORESIS, 1986, 7 (04) : 166 - 171
  • [5] A NEW, HIGHLY SENSITIVE METHOD FOR THE DETECTION AND QUANTIFICATION OF PENICILLIN-BINDING PROTEINS
    GALLENI, M
    LAKAYE, B
    LEPAGE, S
    JAMIN, M
    THAMM, I
    JORIS, B
    FRERE, JM
    BIOCHEMICAL JOURNAL, 1993, 291 : 19 - 21
  • [6] A highly sensitive method for circulating tumour cell antigen quantification in liquid biopsy
    Mumford, K.
    EUROPEAN JOURNAL OF CANCER, 2016, 61 : S51 - S51
  • [7] Protocol: a highly sensitive RT-PCR method for detection and quantification of microRNAs
    Varkonyi-Gasic, Erika
    Wu, Rongmei
    Wood, Marion
    Walton, Eric F.
    Hellens, Roger P.
    PLANT METHODS, 2007, 3 (1)
  • [8] The parallel reaction monitoring method contributes to a highly sensitive polyubiquitin chain quantification
    Tsuchiya, Hikaru
    Tanaka, Keiji
    Saeki, Yasushi
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2013, 436 (02) : 223 - 229
  • [9] Protocol: a highly sensitive RT-PCR method for detection and quantification of microRNAs
    Erika Varkonyi-Gasic
    Rongmei Wu
    Marion Wood
    Eric F Walton
    Roger P Hellens
    Plant Methods, 3
  • [10] Highly sensitive UPLC-MS/MS method for the quantification of paromomycin in human plasma
    Roseboom, Ignace C.
    Thijssen, Bas
    Rosing, Hilde
    Mbui, Jane
    Beijnen, Jos H.
    Dorlo, Thomas P. C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185