Label-free anti-Mullerian hormone sensor based on polyaniline micellar modified electrode

被引:10
|
作者
Yukird, Jutiporn [1 ]
Chailapakul, Orawon [2 ]
Rodthongkum, Nadnudda [3 ]
机构
[1] Chulalongkorn Univ, Nanosci & Technol Program, Grad Sch, Phayathai Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Electrochem & Opt Spect Res Unit, Dept Chem, Fac Sci, Phayathai Rd, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Met & Mat Sci Res Inst, Phayathai Rd, Bangkok 10330, Thailand
关键词
Polyaniline micellar; Anti-Mullerian hormone (AMH); Ovarian predictor; Label-free; Electrochemical immunosensor; ELECTROCHEMICAL IMMUNOSENSORS; GOLD NANOPARTICLES; NANOCOMPOSITE; BIOSENSOR; IMMOBILIZATION; POLYMER; SERUM;
D O I
10.1016/j.talanta.2020.121561
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A label-free electrochemical immunosensor based on polyaniline (PANI) micellar electrode was firstly fabricated for direct AMH detection. To control the size regularity of PANI, a micelle-based method using ammonium peroxydisulfate (APS) as a reducing agent was employed in the polymerization process. The Anti-AMH antibodies were readily immobilized onto PANI via peptide bond to enhance the sensor specificity and sensitivity. This sensor was applied for the detection of AMH, an ovarian response indicator in female related to residual eggs during a woman's monthly cycle. The sensor performances were systematically investigated by differential pulse voltammetry. The anodic peak current decreases with the increase of AMH concentration owing to blocking of electron transfer by AMH. Under the optimal conditions, this sensor offers high sensitivity with a low detection limit of 0.1 ng mL(-1) and a wide linear range of 0.1-4 ng mL(-1), which is sensitive enough to indicate the ability to produce eggs during a woman's monthly cycle. Furthermore, this system requires lower sample volume (5 mu L), while offers the simple fabrication with low cost and no synthetic challenge and faster analysis compared with a standard ELISA. Ultimately, this sensor was successfully applied for the detection of AMH in human serum with satisfactory results. Thus, it might be an alternative tool for AMH screening in clinical setting.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Label-free anti-Müllerian hormone sensor based on polyaniline micellar modified electrode
    Yukird, Jutiporn
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    Talanta, 2022, 222
  • [2] A label-free Electrochemical Immunosensor for Anti-Mullerian Hormone Detection on Graphene-Au Nanocomposite
    Li, Lingling
    Yu, Yongling
    Chen, Ping
    Liu, Weixia
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (08): : 7911 - 7920
  • [3] Label-free parathyroid hormone immunosensor using nanocomposite modified carbon electrode
    Malla, Pravanjan
    Chen, Guan-Cheng
    Liao, Hao-Ping
    Liu, Chi-Hsien
    Wu, Wei-Chi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 880
  • [4] A Rapid, Label-free and Impedimetric DNA Sensor Based on PNA-modified Nanoporous Gold Electrode
    Tao, Wenyan
    Lin, Peng
    Liu, Hong
    Ke, Shanming
    Zeng, Xierong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (11): : 10511 - 10523
  • [5] Label-Free Electrochemical Thrombin Aptasensor Based on Ag Nanoparticles Modified Electrode
    Suprun, Elena
    Shumyantseva, Victoria
    Rakhmetova, Svetlana
    Voronina, Svetlana
    Radko, Sergey
    Bodoev, Nikolay
    Archakov, Alexander
    ELECTROANALYSIS, 2010, 22 (12) : 1386 - 1392
  • [6] Development of anti-Mullerian hormone immunoassay based on biolayer interferometry technology
    Wang, Yu
    Dzakah, Emmanuel Enoch
    Kang, Ye
    Cai, Yanxue
    Wu, Peidian
    Cui, Yue
    Huang, Youzhen
    He, Xiaowei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (21) : 5499 - 5507
  • [7] Quantitative Label-Free Listeria Analysis Based On Aptamer Modified Nanoporous Sensor
    Zhou, Chun-Xia
    Mo, Ri-Jian
    Chen, Zhi-Meng
    Wang, Juan
    Shen, Guo-Zhu
    Li, Yi-Ping
    Quan, Qin-Guo
    Liu, Ying
    Li, Cheng-Yong
    ACS SENSORS, 2016, 1 (08): : 965 - 969
  • [8] DETERMINATION OF INITIAL GONADOTROPIN DOSE BASED ON ANTI-MULLERIAN HORMONE LEVEL.
    Deaton, J.
    Taylor, T. H.
    Reagan, A.
    Glassner, M. J.
    Orris, J. J.
    Wininger, J. D.
    FERTILITY AND STERILITY, 2010, 94 (04) : S159 - S159
  • [9] A label-free DNA sensor based on impedance spectroscopy
    Kafka, J.
    Paenke, O.
    Abendroth, B.
    Lisdat, F.
    ELECTROCHIMICA ACTA, 2008, 53 (25) : 7467 - 7474
  • [10] A Label-Free, Force-Based Microarray Sensor
    Ho, Dominik
    Falter, Katja
    Severin, Philip
    Gaub, Hermann E.
    BIOPHYSICAL JOURNAL, 2009, 96 (03) : 417A - 418A