On Seismic Response of Substation Equipment and Application of Base Isolation to Transformers

被引:40
|
作者
Saadeghvaziri, M. Ala [1 ]
Feizi, B. [1 ]
Kempner, L., Jr. [2 ]
Alston, D. [2 ]
机构
[1] New Jersey Inst Technol, Dept Civil Engn, Newark, NJ 07102 USA
[2] Bonneville Power Adm, Portland, OR 97208 USA
基金
美国国家科学基金会;
关键词
Base isolation; bushings; power substations; seismic response; transformers;
D O I
10.1109/TPWRD.2009.2033971
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents seismic performance of electric substation transformers, and discusses advantages and considerations in the use of base isolation as a viable hazard mitigation option. Substation transformers and bushings are the most critical elements within the power delivery system and their performances during past earthquakes in the U. S. and abroad have not been satisfactory. Finite-element analyses indicate that the interaction between these two critical elements has a significant effect on seismic vulnerability of substations. In light of dynamic characteristics of this equipment, base isolation can be very effective in mitigating this adverse interaction. Furthermore, due to high-inertia reduction, base isolation can also have beneficial effects on the long-term longevity of transformers and on foundation performance during seismic events. Larger displacement demand and uplift, however, are issues that must be considered in the application of base isolation. Through an actual case study (433.3-MVA transformer in a high-voltage substation), a simplified model of the transformer bushing will be developed and the results of fixed base case and base isolated case are compared. Moreover, design concepts will be investigated that will demonstrate larger displacement can be accommodated; and that considering transformer geometry, peak ground acceleration, amount of inertia reduction, and isolator's friction coefficient for this transformer uplift is not an issue.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 50 条
  • [2] A design method on seismic isolation and reduction of post equipment in substation
    Shi G.
    Xie Q.
    Liu Y.
    Lai W.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (24): : 109 - 116and142
  • [3] Seismic response of electrical substation equipment interconnected by flexible conductors
    Filiatrault, A
    Stearns, C
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2004, 130 (05): : 769 - 778
  • [4] Seismic response analysis of substation equipment interconnected by flexible bus
    Xie, Qiang
    Wang, Yafei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (34): : 86 - 92
  • [5] Numerical modeling for the seismic response of interconnected electrical substation equipment
    Ahmet Güllü
    Innovative Infrastructure Solutions, 2023, 8
  • [6] Numerical modeling for the seismic response of interconnected electrical substation equipment
    Gullu, Ahmet
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2023, 8 (01)
  • [7] Seismic performance of indoor substation RC frames with combined base isolation techniques
    Yin, Congru
    Song, Tiange
    Song, Xiaobin
    Gu, Xianglin
    Xiao, Xuwen
    ENGINEERING STRUCTURES, 2023, 284
  • [8] Application of Electronic Transformers in Digital Substation
    Wang, Hongxing
    Zhang, Guoqing
    Guo, Zhizhong
    Wang, Jiaying
    Cai, Xingguo
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 1322 - 1326
  • [9] Application of electronic transformers in digital substation
    Xu, Dake
    Zhao, Jianning
    Zhang, Aixiang
    Jian, Qingzhi
    Huang, Dexiang
    Sun, Zhijie
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (01): : 78 - 82
  • [10] Seismic interaction of interconnected electrical substation equipment
    Filiatrault, A
    Kremmidas, S
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (10): : 1140 - 1149