Detailed gas/particle flow characteristics of an improved down-fired boiler with respect to a critical factor affecting coal burnout: Vent-air inclination angle

被引:12
|
作者
Wang, Qingxiang [1 ]
Chen, Zhichao [1 ]
Han, Hui [1 ]
Tu, Yaojie [2 ]
Liu, Guangkui [3 ]
Zeng, Lingyan [1 ]
Li, Zhengqi [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, 92 West Dazhi St, Harbin 150001, Heilongjiang, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, State Key Lab Coal Combust, Wuhan 430074, Hubei, Peoples R China
[3] China Special Equipment Inspect & Res Inst, Beijing 100029, Peoples R China
关键词
Down-fired boiler; Novel combustion technology; Vent-air inclination angle; PDA; Gas/particle flow characteristics; Pulverized coal burnout; NOX EMISSION CHARACTERISTICS; SUPERCRITICAL UTILITY BOILER; COMBUSTION CHARACTERISTICS; PULVERIZED-COAL; SECONDARY-AIR; AERODYNAMIC CHARACTERISTICS; SWIRL BURNER; FURNACE; RATIO; REDUCTION;
D O I
10.1016/j.energy.2019.06.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
The eccentric-swirl-secondary-air combustion technology has been confirmed to comprehensively solve high NOx emission and poor coal burnout for down-fired boilers with swirl burners. The influence of vent-air inclination angle (beta(v)), a critical factor that affects coal burnout, on gas/particle flow characteristics is investigated to further decrease unburned combustible in fly ash. Gas/particle two-phase flow experiments under different beta(v) (i.e., 10 degrees, 20 degrees, 28 degrees, 40 degrees and 50 degrees) are performed by using a particle dynamic analyser in a 1:10-scale model of the full-scale improved boiler. With increasing beta(v), the under-arch recirculation zone and the recirculation velocities of gas/particle flows continuously increase. In the staged air region, the vertical velocities of gas/particle flows near water-cooled wall for beta(v) of 40 degrees and 50 degrees are still as high as 2-4 m/s, however, the vertical velocities of gas/particle flows basically decay to negative values for smaller beta(v) of 10 degrees and 20 degrees. At furnace section Y/Y-0 from 0.220 to 0.369, the vertical fluctuation velocities of gas/particle flows near water-cooled wall for beta(v) of 40 degrees and 50 degrees are significantly higher than those with beta(v) of 10 degrees, 20 degrees and 28 degrees, and the particle volume flux at the same horizontal position X/X-0 constantly increases with increasing beta(v). Furthermore, the downward ejection ability of vent air to gas/particle flows from burners continuously improves, and the downward depth of gas/particle flows and the space utilization ratio of lower furnace both increase with increasing beta(v). The appropriate inclination angle of vent air for the improved boiler varies from 40 degrees to 50 degrees. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:570 / 584
页数:15
相关论文
共 26 条
  • [1] Experimental Investigations into Gas/Particle Flows in a Down-Fired Boiler: Influence of the Vent Air Ratio
    Ren, Feng
    Li, Zhengqi
    Chen, Zhichao
    Xu, Zhenxing
    Yang, Guohua
    ENERGY & FUELS, 2010, 24 (03) : 1592 - 1602
  • [2] Effect of Declination Angle of Vent Air on Flow Characteristics of a Scale Model of a Down-Fired Utility Boiler with Swirl Burners
    Li, Zhengqi
    Liu, Chunlong
    Yang, Pengfei
    Jing, Xinjing
    Zhang, Hongyu
    Wang, Yang
    Zhang, Xiang
    Chen, Xiachao
    Zhu, Qunyi
    JOURNAL OF ENERGY ENGINEERING, 2013, 139 (04) : 322 - 328
  • [3] Characterization of Coal Combustion and Steam Temperature with Respect to Staged-Air Angle in a 600 MWe Down-Fired Boiler
    Kuang, Min
    Li, Zhengqi
    Ling, Zhongqian
    Chen, Zhuofu
    Yuan, Danyan
    ENERGY & FUELS, 2014, 28 (06) : 4199 - 4205
  • [4] Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler
    Li, Zhengqi
    Ren, Feng
    Zhang, Jie
    Zhang, Xiaohui
    Chen, Zhichao
    Chen, Lizhe
    FUEL, 2007, 86 (15) : 2457 - 2462
  • [5] EXPERIMENTAL STUDY ON THE EFFECTS OF DECLIVITOUS ANGLE OF SECONDARY AIR ON THE FLOW CHARACTERISTICS AND COAL COMBUSTION OF A DOWN-FIRED
    Shi, Jian
    Chen, Yuzhong
    Hou, Yubo
    Yao, Bin
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 1, 2012, : 235 - +
  • [6] Experimental gas/particle flow characteristics of a down-fired 600 MWe supercritical utility boiler at different staged-air ratios
    Kuang, Min
    Li, Zhengqi
    Zhu, Qunyi
    Wang, Yang
    Chen, Lizhe
    Zhang, Yan
    ENERGY, 2012, 42 (01) : 411 - 423
  • [7] Experimental investigation of gas/particle two-phase flow characteristics in a down-fired boiler by PDA measurements
    Wang, Qingxiang
    Chen, Zhichao
    Chen, Qingwei
    Zeng, Lingyan
    Li, Zhengqi
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2019, 107 : 38 - 53
  • [8] Review of gas/particle flow, coal combustion, and NOx emission characteristics within down-fired boilers
    Kuang, Min
    Li, Zhengqi
    ENERGY, 2014, 69 : 144 - 178
  • [9] Study on gas/particle flows in a down-fired boiler with swirl burners: Influence of different outer secondary air vane angle
    Fan, Subo
    Zhu, Qunyi
    Zhu, Xingying
    Li, Zhengqi
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 149 - +
  • [10] Gas/particle two-phase flow characteristics of a down-fired 350 MWe supercritical utility boiler at different tertiary air ratios
    Liu, Chunlong
    Li, Zhengqi
    Zeng, Lingyan
    Zhang, Qinghua
    Hu, Richa
    Zhang, Xusheng
    Guo, Liang
    Huang, Yong
    Yang, Xianwei
    Chen, Liheng
    ENERGY, 2016, 102 : 54 - 64